3-7-3
Installation Method for Video Input Unit
This section describes the method for mounting the Video Input Unit to the PT.
A Video Input Unit can be connected to the NS8, NS10, NS12 or NS15 (except that the NS-
CA001 cannot be connected to the NS15. Also, the NS15 does not support video input from
the NS-CA002, but it does support analog RGB input from the NS-CA002). A Video Input
Unit cannot be connected to the NS5.
1. Mount the Video Board onto the back of the PT so that its expansion interface connector
Precautions
for Safe Use
Installing the Video Input Unit
is inserted into the expansion interface connector on the back of the PT and the respec-
tive screw holes are aligned. Hold the Video Board by the corners keeping it parallel to
back of the PT.
Position of screws for
attaching Board to PT
Push firmly on the connector end of the board to ensure that it is inserted sufficiently.
• Do not touch the surface of the substrate or mounted devices with your bare
• After mounting the Video Input Unit to the PT, all fittings must be tightened
• Always turn OFF the power to PT before mounting or removing the Unit. Fol-
• When the Video Input Unit is installed, the depth of the PT will increase by
hands. Also, discharge static electricity from your body in advance.
with the provided screws. Tighten the screws to a torque of 0.6 N·m.
low the procedures and install the Unit correctly.
24 mm.
To install the Video Input Unit, secure sufficient space inside the control
panel beforehand.
Press here to insert the
Video Board.
Align the positions of the holes.
Screw holes for
attaching expansion
boards
3-7 Installing the Video Input Unit
3-33