S82Y-VM60D Omron, S82Y-VM60D Datasheet

DIN Rail Mtg Bkt K For 600 W

S82Y-VM60D

Manufacturer Part Number
S82Y-VM60D
Description
DIN Rail Mtg Bkt K For 600 W
Manufacturer
Omron
Series
S8VMr
Datasheets

Specifications of S82Y-VM60D

Accessory Type
Mounting Bracket(s)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
S8VM Series
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S82YVM60D
Z2814
Power Supply Featuring OMRON’s Unique, New Undervoltage Alarm Function with
Compact Body Contributing to Machine Downsizing
• New undervoltage alarm function assists in determining causes of errors (S8VM-@@@24A@/P@ only).
• Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only).
• Broad range of possibilities with 8 capacities and 29 models to choose from.
• RoHS-compliant including lead-free construction.
• Safety standards: UL508/60950-1/1604, CSA C22.2 No. 14/No. 60950-1/No. 213, EN50178, EN60950-1 (The 300-, 600-, and
• Harmonic current emissions: Conforms to EN61000-3-2 (except for 15- and 30-W models).
• New, attentive design prevents screws from falling out of terminal block (except for output terminals of 300-, 600-, and 1,500-W
• Finger protection prevents electric shock.
• DIN Rail mounting.
Model Number Structure
■ Model Number Legend
Note: Not all combinations are possible. Please refer to the list of models in Ordering Information on page 2.
Note: 1. The housing and terminal of the connector for the undervoltage alarm output are provided with the S8VM-05024A@/P@, S8VM-
S8VM- @@@@@@@
1. Power Ratings
2. Output Voltage
1,500-W models will not conform to safety standards if the customer replaces the fan.)
models).
Note: Refer to Precautions for Safe Use on page 32.
Switch Mode Power Supply
S8VM (15/30/50/100/150/300/600/1,500-W Models)
015:
030:
050:
100:
150:
300:
600:
152: 1,500 W
05: 5 V
12: 12 V
15: 15 V
24: 24 V
2. Bottom mounting models cannot be used for front mounting. For a front mounting configuration, use a DIN Rail mounting bracket model
3. A forced-air cooling method with a fan is used with 300-, 600-, and 1,500-W models.
10024A@/P@ and S8VM-15024A@/P@.
or Mounting Brackets (sold separately).
100 W
150 W
300 W
600 W
15 W
30 W
50 W
1
2
3 4
3. Configuration/Functions
4. Configuration
None: Open-frame type Standard type
C:
A:
P:
None
D
Covered type
Covered type
Covered type
Switch Mode Power Supply
Bottom mounting type (See note 2.)
DIN Rail mounting bracket type
Standard type
Undervoltage alarm type (Sinking)
(See note 1.)
Undervoltage alarm type (Sourcing)
(See note 1.)
S8VM
1

Related parts for S82Y-VM60D

S82Y-VM60D Summary of contents

Page 1

... Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON’s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing • New undervoltage alarm function assists in determining causes of errors (S8VM-@@@24A@/P@ only). • Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only). ...

Page 2

... M8 bolts and nuts for the output terminals are not included with the S8VM-15224C. 4. The 300-, 600-, and 1,500-W models have fans perform front mounting using the bottom mounting models, use the Mounting Brackets (S82Y-VM@@F, sold separately). 2 Switch Mode Power Supply ...

Page 3

Specifications ■ Ratings/Characteristics Item Power rating Efficiency 5-V models 12-V models 15-V models 24-V models Input Voltage (See note 1.) Frequency (See note 1.) Current 100-V input 200-V input Power factor 100-V input 200-V input Harmonic current emissions Leakage current ...

Page 4

Item Power rating Efficiency 5-V models 12-V models 15-V models 24-V models Input Voltage (See note 1.) Frequency (See note 1.) Current 100-V input 200-V input Power factor 100-V input 200-V input Harmonic current emissions Leakage current 100-V input 200-V ...

Page 5

Connections ■ Block Diagrams S8VM-015@@@@ ( (L) Fuse 2 A INPUT AC (N) /FG S8VM-030@@@@ ( (L) Fuse INPUT 3. (N) /FG S8VM-050@@@@ ( (L) Fuse Noise 2 A INPUT filter AC ...

Page 6

S8VM-100@@@@ (100 W) Inrush Harmonic current current protection Rectification suppression circuit AC (L) Fuse Noise INPUT 3.15 A filter AC (N) Drive Drive control circuit Overcurrent detection circuit /FG S8VM-150@@@@ (150 W) Harmonic current Rectification suppression AC (L) Fuse Noise ...

Page 7

S8VM-600@@C (600 W) AC (L) Noise Fuse INPUT filter (N) Rectification Auxiliary power supply circuit S8VM-15224C (1,500 W) AC (L) Fuse Noise INPUT 30 A filter AC (N) Auxiliary power supply circuit /FG Inrush Harmonic current current ...

Page 8

Construction and Nomenclature ■ Nomenclature 15-W, 30-W, 50-W Models Open-frame Models Covered Models S8VM-015@@/S8VM-015@@D S8VM-015@@C@/S8VM-01524A@ S8VM-030@@/S8VM-030@@D S8VM-030@@C@/S8VM-03024A@ S8VM-050@@/S8VM-050@@D S8VM-050@@C@/S8VM-05024A@/ 100-W Models Open-frame Models Covered Models S8VM-100@@/S8VM-100@@D S8VM-100@@C@/S8VM-10024A@/ ...

Page 9

Engineering Data ■ Derating Curve 15W/30W Standard Mounting/Horizontal Mounting/Face-up Mounting 120 Opened type 100 A 80 Covered type −20 − Ambient temperature (°C) 50W Standard Mounting/Horizontal Mounting ...

Page 10

Mounting Standard Mounting Standard Mounting (DIN Rail Mounting Bracket Models) (Bottom Mounting Models) Correct Correct Horizontal Mounting Correct *1 Face-up Mounting Face-up Mounting (DIN Rail Mounting Bracket Models) Incorrect Correct Face-down Mounting Face-down Mounting (DIN Rail Mounting Bracket Models) ...

Page 11

Overload Protection The Power Supply is provided with an overload protection function that protects the Power Supply from possible damage by short-circuit and overcurrent. When the output current rises above 105% min. of the rated current, the protection function ...

Page 12

... Probable Causes of Power Supply Errors and Troubleshooting Using Undervoltage Alarm Function Check the following information if the Undervoltage Alarm Function operates. Contact your OMRON representative if the Power Supply does not function normally after checking. The symbols in the table are as follows: : Lit, ...

Page 13

Probable cause of error --- A momentary power failure has occurred in the input. A momentary overload has occurred. A momentary output voltage drop has occurred at startup due to the capacity of the capacitive factors on the load side ...

Page 14

Construction and Nomenclature ■ Nomenclature 300-W Models S8VM-300@@C 600-W Models S8VM-600@@C 1,500-W Model S8VM-15224C ■ Output Color Label This color label identifies the output voltage by color. Color label identifying output voltage Note: A 300-W model is shown above. The ...

Page 15

Engineering Data ■ Derating Curve 300W/600W/1,500W 120 100 −20 − Ambient temperature (ºC) Note: 1. Internal parts may occasionally be deteriorated or dam- aged. Do not use the Power Supply ...

Page 16

Remote Control Function This function turns outputs ON and OFF using an external signal while input voltage is applied, using the +RC pin (pin 7 on CN) and the -RC pin (pin 8 on CN). Connect a switch or ...

Page 17

S8VM-600@@C 100 VAC, Load ratio: 100% 100 ms AC input current (10 A/DIV) Output voltage AC input voltage 200 VAC, Load ratio: 100% 100 ms AC input current (10 A/DIV) Output voltage AC input voltage S8VM-15224C 100 VAC, Load ratio: ...

Page 18

Overvoltage Protection Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. When an excessive volt- age ...

Page 19

Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Bottom Mounting Models S8VM-015@@ S8VM-015@@C S8VM-01524A Two, M3 (depth: 8 max.) Note: The image is the S8VM-01524 Model. Two, M3 (depth: 8 max.) Note: The image is the S8VM-01524A ...

Page 20

S8VM-050@@ S8VM-050@@C S8VM-05024A S8VM-05024P 8.5±0.5 Two, M3 (depth: 8 max.) 23.5±0.3 15±0.2 Note: The image is the S8VM-05024 Model. 8.5±0.5 Two, M3 (depth: 8 max.) 23.5±0.3 15±0.2 Note: The image is the S8VM-05024A Model. S8VM-100@@ S8VM-100@@C S8VM-10024A S8VM-10024P 68±0.5 8.5±0.5 ...

Page 21

S8VM-150@@ S8VM-150@@C S8VM-15024A S8VM-15024P 68±0.5 8.5±0.5 Two, M3 (depth: 8 max.) 8.5±0.5 26.5±0.2 15±0.2 7.5±0.2 25±0.5 Note: The image is the S8VM-15024 Model. 68±0.5 8.5±0.5 Two, M3 (depth: 8 max.) 8.5±0.5 26.5±0.2 15±0.2 7.5±0.2 25±0.5 Note: The image is the ...

Page 22

DIN Rail Mounting Bracket Models S8VM-015@@D S8VM-015@@CD S8VM-01524AD Note: The image is the S8VM-01524D Model. Note: The image is the S8VM-01524AD Model. S8VM-030@@D S8VM-030@@CD S8VM-03024AD Note: The image is the S8VM-03024D Model. Note: The image is the S8VM-03024AD Model. ...

Page 23

S8VM-050@@D S8VM-050@@CD S8VM-05024AD S8VM-05024PD Note: The image is the S8VM-05024D Model. Note: The image is the S8VM-05024AD Model. S8VM-100@@D S8VM-100@@CD S8VM-10024AD S8VM-10024PD Note: The image is the S8VM-10024D Model. Note: The image is the S8VM-10024AD Model. 17.6 max. 14 120.5 ...

Page 24

S8VM-150@@D S8VM-150@@CD S8VM-15024AD S8VM-15024PD Note: The image is the S8VM-15024D Model. Note: The image is the S8VM-15024AD Model. 24 Switch Mode Power Supply 17.6 max. 14 160.5 82.5 170.4 5.4 (Sliding: 9 max.) 14 164.5 84.5 46.2 174.4 5.4 (Sliding: ...

Page 25

Bottom Mounting Models S8VM-300@@C Four, M4 (depth: 6 max.) 60±0.5 11 10.5 40±0.5 Note: The image is the S8VM-30024C Model. S8VM-600@@C 101.8 Note: The image is the S8VM-60024C Model. S8VM-15224C 126.5 82 Note: M8 bolts and nuts for the ...

Page 26

... S8VM Model S82Y-VM10B S82Y-VM20B S82Y-VM10F S82Y-VM30B S82Y-VM30S S82Y-VM30F S82Y-VM30D S82Y-VM60B S82Y-VM60S S82Y-VM60F S82Y-VM60D Screws Used A: Accessories (Use the enclosed screws in two places for 15-W and 30-W models and in three places for 50-W mod- B els M3.5 (three places) Mounting screw tightening torque (recommended): 0.49 N· ...

Page 27

... Mounting Bracket C (Front Mounting for 15-, 30- 50-, 100-, and 150-W Models) S82Y-VM10F Mounting Bracket D (Bottom Mounting for 300-W Models) S82Y-VM30B 60 5 195 Using the Mounting Bracket 33 4 dia 105 97±0 8.3 4 13.4 c Screws Used A: Accessories (Use the enclosed screws in two places for 15-W, 30-W and 50- W models and in three places for 100-W and 150-W models ...

Page 28

... Mounting Bracket E (Horizontal Bottom Mounting for 300-W Models) S82Y-VM30S 8 6 Three, 4.5 dia. Mounting Bracket F (Front Mounting for 300-W Models) S82Y-VM30F Two, 4.5 dia 102.3 105 13.5 4 Switch Mode Power Supply Using the Mounting Bracket 202 215 Using the Mounting Bracket 215 ...

Page 29

... Mounting Bracket G (DIN Rail Mounting for 300-W Models) S82Y-VM30D 60 102.3 67 6.4 Mounting Bracket H (Bottom Mounting for 600-W Models) S82Y-VM60B Three, 4.5 dia Mounting Bracket I (Horizontal Bottom Mounting for 600-W Models) S82Y-VM60S Three, 4.5 dia Using the Mounting Bracket 215.3 243 max. 9.5 Using the Mounting Bracket 72 100 202 ...

Page 30

... Mounting Bracket J (Front Mounting for 600-W Models) S82Y-VM60F Two, 4.5 dia 102.3 105 13.5 4.5 105 Mounting Bracket K (DIN Rail Mounting for 600-W Models) S82Y-VM60D 98 102.3 105 6.4 30 Switch Mode Power Supply Using the Mounting Bracket 222.3 257 max. A Using the Mounting Bracket 222 ...

Page 31

... Undervoltage Alarm Output Wiring Cable Terminal and Housing Replacement Fan Unit for 300-W Models Replacement Fan Unit for 600-W Models Replacement Fan Unit for a 1,500-W Model Undervoltage Alarm Output Wiring Cable S82Y-VM60D (for S8VM-05024A@/05024P@/10024A@/10024P@/15024A@/15024P@ Only) : XHP-3 (Manufactured by JST AWG24 3,000± ...

Page 32

Safety Precautions !CAUTION Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Minor burns may occasionally occur. Do not touch the Product while power ...

Page 33

Recommended Wire Sizes Terminal Model Input S8VM-015@@@@ S8VM-030@@@@ S8VM-050@@@@ (M3.5) S8VM-100@@@@ S8VM-150@@@@ S8VM-300@@C S8VM-600@@C (M4) S8VM-15224C Output S8VM-015@@@@ S8VM-030@@@ (M3.5) S8VM-050@@@@ S8VM-100@@@@ (M4) S8VM-150@@@@ S8VM-300@@C (M4) S8VM-600@@C (M5) S8VM-15224C (M8 bolts and nuts) The current rating for the output terminals ...

Page 34

Insulation Test When performing the test, be sure to short-circuit all the output terminals to protect them from damage. Inrush Current When two or more Power Supplies are connected to the same input, inrush current is added to the total ...

Page 35

... Check if the +RC and -RC pins are open. Make the correct connec- tions as specified. Fan Replacement 300/600/1,500-W Models Consult with OMRON regarding fan replacement. OMRON will replace fans for a fee. A replacement Fan Unit (S82Y-VM@@FAN) is available. Use the curve in the graph below as a rough measure of replacement timing ...

Page 36

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 37

Cat. No. T031-E1-02 06/06 Specifications subject to change without notice Printed in USA ...