CS1W-SCU31-V1 Omron, CS1W-SCU31-V1 Datasheet

no-image

CS1W-SCU31-V1

Manufacturer Part Number
CS1W-SCU31-V1
Description
2 RS422/RS485 Serial Ports
Manufacturer
Omron
Datasheet

Specifications of CS1W-SCU31-V1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
In-panel Temperature Controller with Flexible Modular
Design and Wide Integration with Host Devices
• The compact modular structure enables construction of temperature
• Connection can be made to a Programmable Controller without any
• One fully universal-input Unit includes a thermocouple, platinum-resistance
• Connect directly to the G3ZA Multi-channel Power Controller using optimum
• Autotuning (AT) can be used for independent heating/cooling PID control,
• Up to 16 Temperature Controllers can be connected to a single DeviceNet
Ordering Information
■ Temperature Controller
Standard Control Models
Note:
Functional Upgrades
Refer to page 18 for details.
Upgrade functions are supported by the indicated version ("V1.1" or "V1.2") or a higher version of the software.
Basic Unit
(temperature
control)
(See note 1.)
HFU with
Programless
Communications
(See note 1.)
HFU with DeviceNet
Communications
(See note 1.)
End Unit
(See note 1.)
systems optimally suited to the application.
programming required, reducing the number of steps required in ladder
programming design.
thermometer, and analog input for easy selection and reduced inventory
requirements.
cycle control for high-accuracy regulation with minimal noise.
and self-tuning (ST) can be used to calculate the PID constants with the step
response method.
Communications Unit.
Modular Temperature Controller
EJ1
Refer to the following manual for precautionary information and other information necessary to use the EJ1:
EJ1 Modular Temperature Controller User’s Manual (Cat. No. H142)
Name
1. An End Unit is always required for connection to a Basic Unit or an HFU. An HFU cannot operate without a Basic Unit. External communications cannot be performed when using a
2. For heating/cooling control applications, control outputs 3 and 4 on the 2-point models are used for the cooling or heating control outputs.
3. When using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately.
Basic Unit only.
On the 4-point models, heating/cooling control is performed for the two input points.
V1.2
V1.2
24 VDC
supplied
from the
End Unit
24 VDC
voltage
supply
Power
2
4
2
None
control
points
No. of
Voltage output:
2 points
(for SSR drive)
(See note 2.)
Current output:
2 points
None
outputs
Control
1 and 2
Transistor
output: 2 points
(sinking)
Voltage output: 2
points (for SSR
drive) (See note
2.)
Transistor
output: 2 points
(sinking)
None
outputs
Control
3 and 4
None
Transistor output:
4 points (sinking)
None
Transistor output:
2 points (sinking)
Auxiliary
output
2
(See
note 3.)
None
burnout
Heater
alarm
Functions
2
None
2
4
None
None
inputs
Event
Modular Temperature Controller
G3ZA connection
port: RS-485
From End Unit:
Port A or port B:
RS-485
Port C: RS-485 or
RS-232C
selectable.
From End Unit:
Port A: RS-485
Port C: RS-422
From End Unit:
Port A: RS-485
DeviceNet
communications
Port A or B: RS-485
Connector: Port A
Communications
Supports DeviceNet Communications.
functions
Refer to the Safety Precautions on page 21.
Thermocouple,
platinum
resistance
thermometer,
analog voltage,
and analog
current
selectable for
each channel.
No input
Input type
M3 terminal
Screw-less clamp EJ1N-TC2B-QNHB
M3 terminal
Screw-less clamp EJ1N-TC4B-QQ
M3 terminal
Screw-less clamp EJ1N-TC2B-CNB
Screw-less clamp
M3 terminal
Screw-less clamp
Screw-less clamp
M3 terminal
Detachable
connector
M3 terminal
Terminal
EJ1
EJ1N-TC2A-QNHB
EJ1N-TC4A-QQ
EJ1N-TC2A-CNB
EJ1N-HFUA-NFLK
EJ1N-HFUB-NFLK
EJ1N-HFUA-NFL2
EJ1N-HFUB-NFL2
EJ1N-HFUB-DRT
EJ1C-EDUA-NFLK
EJ1C-EDUC-NFLK
Model
1

Related parts for CS1W-SCU31-V1

CS1W-SCU31-V1 Summary of contents

Page 1

Modular Temperature Controller EJ1 In-panel Temperature Controller with Flexible Modular Design and Wide Integration with Host Devices • The compact modular structure enables construction of temperature systems optimally suited to the application. • Connection can be made to a Programmable ...

Page 2

Accessories (Order Separately) Current Transformer (CT) Diameter Model 5.8 dia. E54-CT1 12.0 dia. E54-CT3 G3ZA Connecting Cable Cable length Model 5 m EJ1C-CBLA050 Rail Mounting Equipment Name Model Mounting Rail PFP-100N PFP-50N Specifications Basic Unit/EJ1N-TC ■ Ratings Item Type ...

Page 3

Characteristics Indication accuracy Thermocouple input/platinum resistance thermometer input: Analog input: ±0.5% FS ±1 digit max. CT input: Hysteresis 0.1 to 999.9 EU (in units of 0.1 EU) (See note 2.) Proportional band (P) 0.1 to 999.9 EU (in units ...

Page 4

Communications Specifications Item Port B (See note 1.) Transmission path RS-485 (multipoint) connection Communications RS-485 (two-wire, half duplex) method Synchronization Start-stop synchronization method Communications CompoWay/F, Modbus (See note 4.) protocol Baud rate 9.6, 19.2, 38.4, 57.6, or 115.2 kbps ...

Page 5

Input Ranges Sensor inputs are fully universal. Therefore, platinum resistance thermometer, thermocouple, infrared thermosensor, and analog input can be selected. Inputs can be set for each channel using universal inputs. Input type Platinum resistance thermometer Name Pt100 JPt100 Tem- ...

Page 6

... RS-485/RS-422: Multi-point, RS-232C: Point-to-point (See note 1.) RS-485/RS-422 (two-wire, half duplex), RS-232C Start-stop synchronization • OMRON PLC protocol (Connectable PLCs: SYSMAC CS/CJ/CP Series) • AnA/AnU CPU common commands (Connectable PLCs: MELSEC-An/AnS/FX • MC protocol (form 5) (Connectable PLCs: MELSEC-Q/QnA/QnAS Series) 9.6, 19.2, 38.4, 57.6, or 115.2 kbps ...

Page 7

HFU Unit/EJ1N-HFUB-DRT ■ Ratings Power supply voltage DeviceNet power supply EDU power supply Operating voltage range DeviceNet power supply EDU power supply Power consumption Main functions Ambient temperature range Ambient humidity range ■ Characteristics Insulation resistance Dielectric strength Vibration resistance ...

Page 8

End Unit/EJ1C-EDU ■ Ratings Power supply voltage Operating voltage range Auxiliary output Outputs (See note.) Transistor outputs Ambient temperature range Ambient humidity range Note: Auxiliary output can be allocated using the bus output allocation for each Basic Unit. ■ Characteristics ...

Page 9

Unit Configuration Example ■ Minimal Configuration Small Systems with 2 Channels or 4 Channels Communicating with the Host Device via RS-485 (CompoWay/F Protocol) • Alarms can be allocated to the auxiliary output for the End Unit. • G3ZA/G3PW outputs can ...

Page 10

... G3ZA/G3PW outputs can be used. • Distributed placement is possible by using multiple EJ1C-EDU End Units. • To connect more than one HFU, specific PLC and EJ1 models must be used. Refer to Connecting EJ1 Controllers 1 PLC on page 13. SYSMAC (OMRON PLC) RS-485 MELSEC (Mitsubishi Electric PLC) RS-422 EJ1N-HFU PWR ...

Page 11

Connection Precautions Communications Unit Number Setting • Communications unit numbers can be assigned to Basic Units and HFUs. Restrictions on the Number of Units That Can Be Connected Restrictions for HFUs • One EJ1N-HFU can manage ...

Page 12

... Connecting an EJ1 Controller 1 PLC SYSMAC CS/CJ/CP Series Name Serial Communications Units CJ1W-SCU21-V1 CJ1W-SCU31-V1 CJ1W-SCU41-V1 CS1W-SCU21-V1 (See note.) CS1W-SCU31-V1 Serial Communications Boards CS1W-SCB21-V1 (See note.) CS1W-SCB41-V1 (See note.) CPU Units CJ Series CS Series CP Series Note: Use only products manufactured on or after December 20, 1999. ...

Page 13

... A1SJ71UC24-PRF Model No. FX -232ADP 3U FX -485ADP 3U FX -232- -485-BD 3U V1.1 Model No. CJ1W-SCU31-V1 CJ1W-SCU41-V1 CS1W-SCU31-V1 CS1W-SCB41-V1 (See note.) CP Series EJ1N-HFUA-NFLK EJ1N-HFUB-NFLK Model No. Channel 2 of QJ71C24N QJ71C24N-R4 Channel 2 of A1SJ71QC24N Channel 2 of AJ71QC24N AJ71QC24N-R4 EJ1N-HFUA-NFL2 EJ1N-HFUB-NFL2 Modular Temperature Controller Channel 2 RS-422/485 RS-232C RS-422/485 ...

Page 14

Connection ■ External Connection • Functional insulation is applied between the power supply and the I/O sections. If reinforced insulation is required, connect the input and output terminals to devices without any exposed current-carrying parts or to devices with reinforced ...

Page 15

Nomenclature and Specification Settings ■ Part Names PWR 1 COM1 EJ1N-TC Operation RUN 2 COM2 ERR 3 COM3 Indicators ALM 4 OUT OPN PWR 1 RUN 2 SW1 ERR 3 ALM 4 SW1 ON SW2 6 SW2 Operation Indicators Operation ...

Page 16

Specification Settings Switch Operation • Check that the EJ1 is turned OFF before operating any switch other than pin 6 of SW2. Settings are read only when power is turned ON. • Set the switches with a small flat-blade ...

Page 17

... Temperature Controller Flashing: The copy operation failed. Meaning --- Upload/Download OFF → min max.) → OFF --- Not used. OFF Use the OMRON Configurator. ON Use universal Configurator. (EDS files supported) Upload (from Temperature Controller to DeviceNet Communications Unit) ON Download (from DeviceNet Communications Unit to Temperature Controller) OFF Simple allocation to TC2 Units ...

Page 18

Functional Upgrades Functions depend on the version that you are using. The functional upgrades are given below. Refer to the User's Manual (Cat. No. H142) for details. Version Applicable Unit Basic Units • Modbus communications can be used on port ...

Page 19

Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Temperature Controller Basic Units EJ1N-TC HFUs EJ1N-HFU@-NFL@ HFUs EJ1N-HFUB-DRT End Units EJ1C-EDU 31 31 PWR 1 COM1 PWR 1 COM1 RUN 2 EJ1N COM2 RUN 2 EJ1N- ...

Page 20

Options Current Transformer (Sold Separately) E54-CT1 E54-CT3 40@ 15 E54-CT3 Accessory • Armature Approx. 3 dia. 18 • Plug Approx. 6 dia. (22) Rail Mounting Equipment (Order Separately) DIN Rail PFP-100N 4.5 PFP-50N End Plate PFP-M ...

Page 21

Safety Precautions !CAUTION Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock. Use a power supply that complies with the reinforced insulation specified in IEC 60664 for ...

Page 22

Precautions for Correct Use Installation 1. Do not connect the End Unit directly to an HFU. 2. Connect the End Unit to the right side of a Basic Unit. 3. Connect the HFU to the left side of the ...

Page 23

Removing the Terminal Block 1. Press down the terminal block lever. Lower the lever. 2. Pull out the terminal block. Pull out. Mounting to the DIN Rail Mounting Catch the hook located on the top of the Unit onto the ...

Page 24

I/O Devices ■ Examples of EJ1-series Temperature Controllers/Output Devices Input device/sensor Analog quantities, such as temperature, flow rate, and concentration Converters, Digital Panel Meters, Flow Meters, Infrared Thermosensors, Displacement Sensors ES1B Infrared Thermosensor ES2-HB Humidity Sensor ES2-THB Temperature/Humidity Sensor Thermocouple/Platinum ...

Page 25

CX-Thermo Support Software Ver. 4.1 EST2-2C-MV4 Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H, E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers Enabling Faster Parameter Setup, Device Adjustment, and Maintenance • Enables editing and batch-downloading parameters from a personal computer, reducing the work ...

Page 26

USB-Serial Conversion Cable E58-CIFQ1 Cable for Support Software Enables Connection Even with Temperature Controllers Not Equipped with Communications • Easily set Temperature Controller parameters by connecting the computer's USB port and an EJ1 new-model E5CN, E5AN, or E5EN. ...

Page 27

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 28

... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...

Related keywords