Connection
■ External Connection
• Functional insulation is applied between the power supply and the I/O sections. If reinforced insulation is required, connect the input
• To comply with the standards for noise terminal voltage for class A in EN 61326, install a noise filter (Densei Lamda MXB-1206-33 or
• Use an SELV power supply that provides overcurrent protection. An SELV circuit is one separated from the power supply with double
EJ1N-TC4
EJ1N-HFU@-NFL@
EJ1C-EDUA
Note: 1. To connect to the G3ZA, separately purchase a G3ZA Connecting Cable (EJ1C-CBLA050) and connect it to the G3ZA connection port (CN1) on the EJ1.
14
and output terminals to devices without any exposed current-carrying parts or to devices with reinforced insulation suitable for the
maximum operating voltage of the power supply and I/O sections.
the equivalent) to the DC power line as close as possible to the Temperature Controller.
insulation or reinforced insulation, that does exceed an output voltage of 30 V r.m.s. and 42.4 V peak or 60 VDC max. The OMROM
S8VM or S8VS Series is recommended for the power supply.
Model with Screw Terminals
2. To connect to a computer using the port A connector, use a separately sold E58-CIFQ1 USB-Serial Conversion Cable. The Temperature Controller can be
3. Models with screw-less clamp terminals have terminals A10 and B10, but they are not used. Do not connect anything to them.
Port C
connected to a computer using USB.
RS-485 for port C and RS-232C can be switched.
A separate EJ1 model must be used for
RS-422 communications.
Analog
input
mA
mA
V
V
Not used
RDB (+)
RDA (−)
Modular Temperature Controller
RS-422
Input power supply
SUB4
SUB2
12 VDC
Port A connector
Pt
OUT2
OUT1
A
B
B
A
B
B
Port A
Port B
12 VDC
Not used
SUB2
B (+)
A (−)
RS-485
RS-485
SUB3
SUB1
RS-485
CH2
CH1
Thermo-
couple
24 VDC
SUB1
B (+)
A (−)
B (+)
A (−)
B1
B2
B3
B4
B5
B6
B7
B8
B9
B1
B2
B3
B4
B5
B6
B7
B8
B9
+
1
2
3
4
5
6
7
8
9
CN1 G3ZA connection port
These two ports
cannot be used at
the same time.
These terminals are
used for distributed
placement of Units
when an HFU is used.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A1
A2
A3
A4
A5
A6
A7
A8
A9
RS-232C
CH4
CH3
12 VDC
EV3
EV1
12 VDC
SD
RD
SG
OUT4
OUT3
EV4
EV2
A
B
B
A
B
B
Not used
SDB (+)
SDA (−)
RS-422
mA
mA
V
V
EJ1
Port C
EJ1N-TC2
EJ1N-HFUB-DRT
EJ1C-EDUC
DeviceNet Connector
Model with Connector Terminal Block
4 to 20 mA DC/0 to 20 mA
Models with
linear outputs
4 to 20 mA DC/0 to 20 mA
OUT2
OUT1
Analog
input
Input power supply
Port A connector
mA
mA
V
V
Port A
Port B
RS-485
RS-485
12 VDC
Models with
pulse outputs
24 VDC
Pt
SUB2
SUB1
OUT2
OUT1
A
B
B
A
B
B
12 VDC
B (+)
A (−)
B (+)
A (−)
CH2
CH1
Thermo-
couple
+
V+
CAN H
CAN L
V−
10
1
2
3
4
5
6
7
8
9
B1
B2
B3
B4
B5
B6
B7
B8
B9
CN1
These terminals are
used for distributed
placement of Units
when an HFU is used.
These two ports
cannot be used at
the same time.
Power line
Communications line, high
Shield
Communications line, low
Power line
G3ZA connection port
A1
A2
A3
A4
A5
A6
A7
A8
A9
CT1
EV1
OUT4
OUT3
CT2
EV2
Not provided
on models
with linear
output.
Provided only
on models
with pulse
output.

Related parts for CS1W-SCU31-V1