CS1W-SCU31-V1 Omron, CS1W-SCU31-V1 Datasheet - Page 25

no-image

CS1W-SCU31-V1

Manufacturer Part Number
CS1W-SCU31-V1
Description
2 RS422/RS485 Serial Ports
Manufacturer
Omron
Datasheet

Specifications of CS1W-SCU31-V1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H,
E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers Enabling
Faster Parameter Setup, Device Adjustment, and Maintenance
• Enables editing and batch-downloading parameters from a personal
• Supports Trend Monitoring:
• Supports parameter masks to hide parameters unnecessary to
• Logic operations enable setting inputs from external inputs (event
• Easy adjustment of control performance by fine-tuning.
∗ Fine-tuning instructs the CX-Thermo to calculate a PID parameters by
Ordering Information
■ List of Models
Specifications
CX-Thermo Support Software
Compatible
devices
Personal
computer
system
requirements
Connection method
directly inputting commands to improve response.
computer, reducing the work required to set parameters.
Usability is improved with table-formatted parameter editing from
version. 4.0.
Monitor data (PV, SP, MV, PID parameter, Alarm ON/OFF, etc.) for
up to 31 E5@N/@N-H Temperature Controllers.
Connect up to 64 EJ1N, 17 EJ1G, or 16 E5ZN Temperature
Controllers. (The Temperature Controllers must be from the same
series.)
display. (Supported only by the E5@N/@N-H and E5@R/@R-T).
inputs) or temperature status, outputs to external outputs (control or
auxiliary outputs), and changing operating status with ON/OFF
delays.
(Supported only by the E5@N/@N-H).
CX-Thermo Support Software Ver. 4.1
EST2-2C-MV4
Temperature
Controllers
OS
CPU
Memory
Harddisk
CD-ROM
Monitor
Communications ports
Name
E5CN (available from April 2004)
E5AN, E5EN (available from February 2005),
E5CN-H, E5AN-H, E5EN-H
E5AR, E5ER
E5AR-T, E5ER-T
E5ZN
EJ1N-TC4, EJ1N-TC2, EJ1N-HFU
EJ1G-TC4, EJ1G-TC2, EJ1G-HFU
G3ZA (only when connected to EJ1N-TC4, EJ1N-TC2, EJ1G-TC4, EJ1G-TC2)
Note: Models with DeviceNet communications are not supported.
Windows 2000 (service pack 3 or higher), XP, or Vista
300 MHz min.
128 MB min.
300 MB min. available space
One CD-ROM drive min.
SVGA (800 × 600) min.
• RS-232C port, or USB port, 1 port min.
• An E58-CIFQ1 USB-Serial Conversion Cable is required to connect a computer to the setup tool port
• A K3SC Interface Converter is used to connect a computer to models with RS-422/RS-485
• An E58-CIFIR USB-Infrared Conversion Cable is required to wirelessly connect a computer to models
the E5@N, E5@N-H, or EJ1.
communications.
with infrared communications (E5AN-H or E5EN-H).
EST2-2C-MV4
CX-Thermo Support Software Ver. 4.1
Model
EST2-2C-MV4
25