D4F-202-3R Omron, D4F-202-3R Datasheet

no-image

D4F-202-3R

Manufacturer Part Number
D4F-202-3R
Description
Small Safety Limit Switch
Manufacturer
Omron
Series
D4Fr
Datasheet

Specifications of D4F-202-3R

Lead Free Status / Rohs Status
 Details
Smallest Class of Safety Limit Switches in
the World
Model Number Structure
Model Number Legend
1. Built-in Switch
2. Actuator
Ordering Information
List of Models
Safety Limit Switches (with Direct Opening Mechanism)
Consult with your OMRON representative when ordering any models that are not listed in this table.
D4F-@@-@@
• The world's smallest limit switch with a direct opening
• High-sensitivity safety limit switch.
• Built-in switches with two- or four-contact construction are
• Degree of protection: IP67 (EN60947-5-1)
• Certified standards: UL, EN (TÜV), and CCC
Roller lever
(Metal lever,
resin roller)
Roller
plunger
(Metal roller)
Small Safety Limit Switch
D4F
mechanism (four-contact construction model).
available.
Actuator
1: 1NC/1NO (slow-action)
2: 2NC (slow-action)
3: 2NC/2NO (slow-action)
4: 4NC (slow-action)
02: Roller plunger
20: Roller lever
(Metal roller)
(Metal lever, resin roller)
Be sure to read the “Safety Precautions” on page 6
and the “Precautions for All Safety Limit Switches” .
1 2
3 4
1 m
3 m
5 m
1 m
3 m
5 m
length
Cable
Horizontal
Vertical
Horizontal
Vertical
Horizontal
Vertical
Horizontal
Vertical
Horizontal
Vertical
Horizontal
Vertical
direction of cable
Pull-outing
D4F-120-1R
D4F-120-1D
D4F-120-3R
D4F-120-3D
D4F-120-5R
D4F-120-5D
D4F-102-1R
D4F-102-1D
D4F-102-3R
D4F-102-3D
D4F-102-5R
D4F-102-5D
Model
(slow-action)
1NC/1NO
opening
Direct
D4F-220-1R
D4F-220-1D
D4F-220-3R
D4F-220-3D
D4F-220-5R
D4F-220-5D
D4F-202-1R
D4F-202-1D
D4F-202-3R
D4F-202-3D
D4F-202-5R
D4F-202-5D
Model
(slow-action)
3. Cable Length
4. Pull-outing direction of cable
1: 1 m
3: 3 m
5: 5 m
R: Horizontal
D: Vertical
2NC
Note: Contact your sales representative for details on
opening
Direct
Built-in switch
models with safety standard certification.
D4F-320-1R
D4F-320-1D
D4F-320-3R
D4F-320-3D
D4F-320-5R
D4F-320-5D
D4F-302-1R
D4F-302-1D
D4F-302-3R
D4F-302-3D
D4F-302-5R
D4F-302-5D
Model
(slow-action)
2NC/2NO
opening
Direct
D4F-420-1R
D4F-420-1D
D4F-420-3R
D4F-420-3D
D4F-420-5R
D4F-420-5D
D4F-402-1R
D4F-402-1D
D4F-402-3R
D4F-402-3D
D4F-402-5R
D4F-402-5D
CSM_D4F_DS_E_3_1
Model
(slow-action)
4NC
opening
Direct
1

Related parts for D4F-202-3R

D4F-202-3R Summary of contents

Page 1

... D4F-120-1R D4F-220-1R D4F-120-1D D4F-220-1D D4F-120-3R D4F-220-3R D4F-120-3D D4F-220-3D D4F-120-5R D4F-220-5R D4F-120-5D D4F-220-5D D4F-102-1R D4F-202-1R D4F-102-1D D4F-202-1D D4F-102-3R D4F-202-3R D4F-102-3D D4F-202-3D D4F-102-5R D4F-202-5R D4F-102-5D D4F-202-5D CSM_D4F_DS_E_3_1 models with safety standard certification. 2NC/2NO 4NC (slow-action) (slow-action) Direct Model Model opening D4F-320-1R D4F-420-1R ...

Page 2

... UL/CSA (UL508, CSA C22.2 No. 14) C300 Rated Carry current voltage File No. 120 VAC 2 240 VAC Q300 E76675 Rated 20030103050 Carry current voltage 64266 125 VDC 2.5 A 250 VDC D4F AC-15 DC-13 ) 0. 240 V 250 V e Current (A) Volt-amperes (VA) Make Break Make Break 15 1.5 1,800 180 7 ...

Page 3

... Hz, 0.75 mm single amplitude 2 1,000 m/s min. 2 300 m/s min. 100 A (EN60947-5-1) 2.5 A (EN60947-5-1) −30 to 70°C (with no icing) 95% max. UL2464 No. 22 AWG, finishing O.D.: 8.3 mm Approx. 190 g (D4F-102-1R, with 1 m cable) Approx. 220 g (D4F-120-1R, with 1 m cable) D4F 3 ...

Page 4

... Zb 11-12 12 21-22 22 31-32 41-42 32 Stroke 42 D4F Head The plunger type of actuator can be used in a normal direction and reverse direction. Cable The cable can be pulled out in a horizontal direction vertical direction. Remarks Only NC contact 11-12 has a certified direct opening mechanism. ON The terminals 11-12 and 33-34 can be used as unlike poles ...

Page 5

... The OF value is the maximum load that opens an NC contact (11-12, 21-22, 31-32, 41-42). *2. The RF value is the minimum load that closes an NC contact (11-12, 21-22, 31-32, 41-42). *3. The PT2 and TT values are reference values. *4. The D4F is used in accordance with EN81 and EN115 at a minimum DOT of 30° and 2.8 mm. Roller plunger (Metal roller) D4F-@02-@R (30 ...

Page 6

... Lever mounting screw (M5) 2.4 to 2.8 N·m 2 Body mounting screw (M4) 1.18 to 1.37 N· Mounting Use two M4 screws and washers to mount the D4F securely. The D4F can be mounted more securely with proper tightening torque. Mounting Holes (Unit: mm) Two, 4.2-dia screw hole 20± 0.1 Changing the Lever Angle • ...

Page 7

... Terminal Numbers • Identify terminal numbers based on the color (with or without white lines) of the insulation on the wire. • The safety and auxiliary contacts of D4F models of four-terminal contact construction and those of two-terminal contact construction are described below. • The safety contacts are direct-opening NC contacts (11-12 and 21- 22) ...

Page 8

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords