D4F-220-5D Omron, D4F-220-5D Datasheet
D4F-220-5D
Specifications of D4F-220-5D
Related parts for D4F-220-5D
D4F-220-5D Summary of contents
Page 1
... The D4F requires 6 degrees to respond. • On the table that allows machine tools etc. to move at an increasing speed, the moment the dog pushes the actuator, the D4F responds. • ...
Page 2
... Pull-outing direction of cable R: Horizontal D: Vertical 1NC/1NO 2NC (slow-action) (slow-action) D4F-120-1R D4F-220-1R D4F-120-1D D4F-220-1D D4F-120-3R D4F-220-3R D4F-120-3D D4F-220-3D D4F-120-5R D4F-220-5R D4F-120-5D D4F-220-5D D4F-102-1R D4F-202-1R D4F-102-1D D4F-202-1D D4F-102-3R D4F-202-3R D4F-102-3D D4F-202-3D D4F-102-5R D4F-202-5R D4F-102-5D D4F-202-5D D4F Built-in switch 2NC/2NO 4NC (slow-action) (slow-action) D4F-320-1R ...
Page 3
... Cable UL2464 No. 22 AWG, finishing O.D.: 8.3 mm Weight Approx. 190 g (D4F-102-1R, with 1-m cable) Approx. 220 g (D4F-120-1R, with 1-m cable) Note: 1. The above values are initial values. 2. Once the contact is opened or closed with an ordinary load, it cannot be used for a load smaller than that. The contact surface may be rough, which impairs the reliability of contacting ...
Page 4
... The OF value is the maximum load that opens an NC contact (11-12, 21-22, 31-32, 41-42). 3. The RF value is the minimum load that closes an NC contact (11-12, 21-22, 31-32, 41-42). 4. The PT2 and TT values are reference values. 5. The D4F is used in accordance with EN81 and EN115 at a minimum DOT of 30° and 2.8 mm. Connections ■ Contact Form ...
Page 5
... Has a direct opening mechanism separating the contacts when the NC contacts are welded. . Small Safety Limit Switch Head The plunger type of actuator can be used in a normal direction and reverse direction. Cable The cable can be pulled out in a horizontal direction vertical direction. D4F B-33 ...
Page 6
... Precaution for Safe Use Be sure to connect a ground line, otherwise an electric shock may occur. If the D4F used as a switch in an emergency stop circuit safety circuit for preventing accidents resulting in injuries or deaths, use NC contacts with a forced release mechanism and set the D4F so that it will operate in direct opening mode ...
Page 7
... D4F, test the D4F under actual operating conditions and be sure to use the D4F in actual operation within switching times that will not lower the performance of the D4F. Tightening Torque Be sure to tighten each screw of the D4F properly, otherwise the D4F may soon malfunction. No. Type ...
Page 8
... Terminal Numbers Identify terminal numbers based on the color (with or without white lines) of the insulation on the wire. The safety and auxiliary contacts of D4F models of four-terminal contact construction and those of two-terminal contact construction are described below. The safety contacts are direct-opening NC contacts (11-12 and 21- 22) ...
Page 9
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 10
Cat. No. GC SAFETY-3 07/05 Specifications subject to change without notice Printed in USA ...