D4GL-4GDG-A4-NPT Omron, D4GL-4GDG-A4-NPT Datasheet - Page 6

no-image

D4GL-4GDG-A4-NPT

Manufacturer Part Number
D4GL-4GDG-A4-NPT
Description
3NC ,MetalHead,SOL.Lock
Manufacturer
Omron
Series
D4GLr
Datasheet

Specifications of D4GL-4GDG-A4-NPT

Lead Free Status / Rohs Status
 Details
Connections
Internal Circuit Diagram
Indicator
Circuit Connection Example
(Green)
• Terminals 12 and 41 are connected internally and so connect
• Connect terminals 21 and 22 and terminals 51 and 52 in series
• In the following connection example, terminals 21 and 22 and
CRD CRD
LED
terminals 11 and 42 for safety-circuit input. (BIA GS-ET-19)
when using as safety-circuit input (redundancy circuit for terminals
11 and 12 and terminals 41 and 42 above). Connect the terminals
individually when using as auxiliary-circuit input (e.g., terminals 21
and 22 for safety-door open/closed monitoring and terminals 51
and 52 for monitoring the lock status).
terminals 51 and 52 are used as auxiliary-circuit input.
(Orange)
LED
ZD
ZD
D
D
Green (+)
Orange (+)
COM (−)
5 to 24V DC
Solenoid
E1 (+)
E2 (−)
24V DC
Connection Example for D4GL-1HFA-A
* The terminal number of green indicator will be different according to
D4GL-@@@@-@@
• Direct opening contacts used as safety-circuit input are indicated
• Connect the indicators in parallel to the auxiliary circuits or
• Although the 3 lines are connected at the time of delivery, rewire
• The following table shows the connection configuration required to
• If an indicator is connected in parallel to a direct opening contact,
• Do not switch circuits for two or more standard loads at the same
• DC solenoids have polarity. Confirm terminal polarity before wiring.
Orange indicator (+)
Green indicator (+)
the contact configuration.
with the
Terminals 11 and 12 and terminals 21 and 22 are direct opening
contacts.
terminals E1 and E2.
them as necessary for the application.
make the green indicator light when the door is closed and the
orange indicator light when the solenoid turns ON.
“2” : A, B, E, or F =33
“2” : C or D
“2” : G or H
when the indicator breaks, a short-circuit current will be generated,
possibly resulting in an installation malfunction.
time. Doing so may adversely affect insulation performance.
E1
11
21
32
Common (-)
Indicator
O3 (Orange)
O1 (Green)
2
mark.
=21
=31
(Orange)
12
(Green)
LED
LED
51
Terminal
number
O2
(Black)
41
O1
O3
O2
Solenoid
Lead wire
42
52
22
31
E2
Orange
Green
color
Black
Safety
circuit
Auxiliary
circuit
Auxiliary
circuit
Auxiliary
circuit
Connected
terminal
number
D4GL
31 *
E1
E2
6