E5AN-HAA2HBMD-500 AC/DC24 Omron, E5AN-HAA2HBMD-500 AC/DC24 Datasheet

no-image

E5AN-HAA2HBMD-500 AC/DC24

Manufacturer Part Number
E5AN-HAA2HBMD-500 AC/DC24
Description
High Function 1/4Din Opt Out
Manufacturer
Omron

Specifications of E5AN-HAA2HBMD-500 AC/DC24

No. Of Digits / Alpha
5
Meter Function
Temperature Controller
Meter Range
-200°C To +2300°C
Digit Height
15mm
Supply Voltage Range
24 VAC/VDC
Power Consumption
4W
Rohs Compliant
Yes
Operating Temperature Range
-10°C To +55°C
A New High-performance Controller: High Resolution, High Speed, and
High Input Accuracy.
Logic Operations and Preventive Maintenance Function. Plus Infrared
Port on Front Panel.
Main I/O Functions
• High-resolution display with 5 digits/0.01°C display.
• High-speed sampling cycle of 60 ms.
• High Accuracy
• Universal inputs on all models (thermocouple, PT, or analog input)
• A PV/SV-status display function can be set to automatically
• Flexible contact outputs with logic operations (AND, OR, and
• Preventive maintenance for relays in the Temperature Controller
• Model available with position-proportional control
Universal Sensor Inputs
• Universal thermocouple/
Indication Accuracy
• Thermocouple/Pt input:
• Analog input:
Sampling Period
• 60 ms
Advanced Digital Temperature Controller
E5AN-H/E5EN-H
(96 x 96 mm and 48 x 96 mm)
Thermocouple/Pt input: ±0.1% of PV
Analog input: ±0.1% FS
to handle various sensors with one Controller. Models also
available with Remote SP.
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or
SV.
delays) set from the Support Software (CX-Thermo Ver. 4.0)
using a Control Output ON/OFF Counter.
(current/voltage) inputs.
Pt/analog
±0.1% of PV
±0.1% FS
Remote SP Input
• One
Event Inputs
• None
• Two
• Four
PF Key
(Programmable
key function)
Control Output 1
(built-in)
• SSR outputs
E5AN-H
Control Output 2
(built-in)
• SSR outputs
Output Unit
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output
USB
Infrared port
Output Unit
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output
E5EN-H
Computer Support Software
CX-Thermo
Refer to Operation for E5
procedures.
3-level Display
Simultaneously displays set items, such as the
PV, SV, and MV.
5-digit Display with high resolution of 0.01°C
Refer to Safety Precautions for E5
96 × 96 mm
E5AN-H
Auxiliary Outputs
• Two
• Three
CSM_E5AN-H_E5EN-H_DS_E_3_2
@
N/E5
• Auto/manual switching
• Temperature Controller
• Simple program
• Logic operations
• Control output ON/OFF
• PV change rate alarm
• Models available with
status display
function
count alarm
RS-485, RS-422, or
RS-232C
communications
@
N-H for operating
48 × 96 mm
E5EN-H
@
N/E5
@
N-H.
1

Related parts for E5AN-HAA2HBMD-500 AC/DC24

E5AN-HAA2HBMD-500 AC/DC24 Summary of contents

Page 1

... Control Output 1 (built-in) Output Unit • SSR outputs • Relay output • Voltage output (for driving SSR) • Current output • Linear voltage output CSM_E5AN-H_E5EN-H_DS_E_3_2 96 × × E5AN-H E5EN Refer to Safety Precautions for E5 N/E5 N- N/E5 N-H for operating • Auto/manual switching • ...

Page 2

... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157) E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159) ...

Page 3

... E5AN-HAA2HBMD-500 input 4 to 20-mA E5AN-HSS2HBMD-500 input 4 to 20-mA E5AN-HAA2HHBFMD-500 input 4 to 20-mA E5AN-HSS2HHBFMD-500 input 4 to 20-mA E5AN-HAA3BFMD-500 input 4 to 20-mA E5AN-HSS3BFMD-500 input 4 to 20-mA E5AN-HPRR2BMD-500 input 4 to 20-mA E5AN-HPRR2BFMD-500 input 4 to 20-mA E5AN-HAA2HBM-W-500 input 4 to 20-mA E5AN-HAA2HHBFM-W-500 input 4 to 20-mA E5AN-HAA2HBMD-W-500 ...

Page 4

... Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Connectable models E5AN-H E5EN-H Note: The Waterproof Packing is included with the Controller. Current Transformers (CTs) Hole diameter 5.8 dia. 12.0 dia. CX-Thermo Support Software E5AN-H/E5EN-H Model Transfer RSP output 4 to 20-mA E5EN-HAA2HBM-500 input 4 to 20-mA E5EN-HSS2HBM-500 input ...

Page 5

... Set digitally using keys on the front panel or by using the RSP input. 11-segment digital display and individual indicators (7-segments displays also possible) Character height: E5AN-H: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN-H: PV: 11.8 mm, SV: 8.1 mm, MV: 5.8 mm Indication method Content of 3-level display: PV/SV/MV, PV/SV/Bank No., or soak time remain ...

Page 6

... JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) E5AN-H/E5EN-H Analog input 2300.0 1800.0 1700.01700.0 1300.0 1300.0 Usable in the following ranges by scaling: − ...

Page 7

... Controllers User's Manual Basic Type (Cat. No. H156) for L SP information on the loop burnout alarm (LBA). H > < 0 *9. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature ⏐H⏐ ≤ ⏐L⏐ Controllers User's Manual Basic Type (Cat. No. H156) for information on the PV change rate alarm. ...

Page 8

... Provided on the bottom of the E5AN-H and E5EN-H. An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN-H and E5EN-H. Setup Tool port Provided on the front of the E5AN-H and E5EN-H. An E58-CIFIR USB-infrared Conversion Cable is required to connect the computer to the E5AN-H or E5EN-H. *4 Approved UL 61010-1, CSA C22 ...

Page 9

... Accessories (E54-CT3 only) Plugs (2) USB-Infrared Conversion Cable Applicable OS Windows 2000, XP, or Vista Applicable software CX-Thermo version 4.0 or higher Applicable models E5AN-H/E5EN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) Connector specifications Temperature Controller: Infrared ...

Page 10

... Switching current (A) E5AN-H/E5EN-H SSR Outputs (OUT1/OUT2) Ratings • Rated load voltage 250 VAC • Rated load current (resistive load) Note: 1. The load current must be within the derating curve. 2. There is no zero-cross function. Derating Curve for SSR Outputs (Reference Values) 1.5 1.25 ...

Page 11

... Input power supply supply SSR Open SSR Closed Auxiliary output 2 Auxiliary output Auxiliary output 1 Auxiliary output E5AN-H/E5EN-H Communications E53-EN03 E53-AKB RS-485 Event Inputs 11 11 RDB B (+) EV2 RDA (− NOT USE SDB 21 B (+) (−) 22 SDA Auxiliary output 3 Relay output SPDT, 250 VAC ...

Page 12

... E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers. Terminal Cover Mounting Bracket (E53-COV16) (Accessory) (Accessory) Crimp terminal size: M3.5 120 min. E5AN-H/E5EN-H SUB1 SUB2 HA SUB3 PV No.1 display SV No.2 display RSP ...

Page 13

... E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers Terminal Cover (E53-COV16) (Accessory) Crimp terminal size: M3.5 120 min. E5AN-H/E5EN-H Group Mounted * +1.0 (48 × number of units − 2. Group mounting does not allow waterproofing. ...

Page 14

... USB connector (type A plug) Terminal Covers E53-COV16 (Six Covers provided.) (2,000) With Mounting Adapter Connected 39 16 18.5 Mounting Adapter (Accessory) 99.2 23.1 21.8 (75) (2,100) LED indicator: SD 250 1.2 3.2 10 44.8 E5AN-H/E5EN-H 54 35.8 4.6 dia. LED indicator: RD LED indicator: SD 17.8 1,765 Serial connector LED indicator ...

Page 15

... Two, 3.5 dia. 2.36 dia dia. 9 Two, M3 (depth 4) Armature Lead E5AN-H/E5EN-H E54-CT1 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 Ω 100 ∞ 10 Distortion 1 kΩ ...

Page 16

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords