G6B-4BND DC12 Omron, G6B-4BND DC12 Datasheet

no-image

G6B-4BND DC12

Manufacturer Part Number
G6B-4BND DC12
Description
RELAY TERMINAL BLOCK -STD.
Manufacturer
Omron
Series
G6B-4r
Datasheet

Specifications of G6B-4BND DC12

Relay Type
General Purpose
Contact Form
4PST (4 Form A)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
19.1mA
Coil Voltage
12VDC
Turn On Voltage (max)
9.6 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Circuit
4PST (4 Form A)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
9.6 VDC
Control Off Voltage (min)
1.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6B-4BNDDC12
G6B-4BNDDC12
G6B4BNDDC12
Z2982
Compact Terminal Relay with 4 Independent
Outputs
• Equipped with four G6B Mini-relays that are compact, highly
• Sealed plastic construction used for relays.
• Easy wiring with separated input/output terminals.
• Special P6B Mounting Socket used to facilitate maintenance
• Standard models meet UL508 and CSA requirements.
• DIN Track mounting, and screw mounting models are available.
Model Number Structure
■ Model Number Legend
Note: UL508 and CSA requirements met by standard models.
1. Number of Poles
Ordering Information
■ List of Models
Note: 1. For replacement relays, use relays with the same voltage specifications as the relays provided with the Terminal when it was purchased.
202
G6B-@@@@ND
Equipped with operation
indicator and diode to
absorb coil surge
sensitive, and highly resistant to dielectric surges, and that can
switch 5 amps of power.
(except for high-reliability models).
Terminal Relay
G6B-4@@ND
4:
47:
48:
Classification
2. Standard models are also available without relays mounted to the sockets. To obtain such terminals, replace the “G6B” portion of the
1 2
4 poles (4PST-NO standard circuit)
4 poles (4PST-NO long-life circuit)
4 poles (4PST-NO high-reliability circuit)
Longer operating life can be achieved by replacing the G6B-4@@ND with the G6B-1147P-FD-US.
model number with “P6BF.” For example, to order G6B-4BND with empty sockets, use model number P6BF-4BND. Also specify voltage
specifications for models with operation indicators.
Terminal Relay
3
4PST (standard)
4PST (long-life)
4PST (high reliability)
4PST (standard)
4PST (standard)
Contact form
G6B-4@@ND
DIN Track or screw
mounting
DIN Track or screw
mounting
DIN Track or screw
mounting
Screw mounting
Screw mounting
Mounting method
2. Mounting
3. Input Terminal
Phillips screw terminal
Phillips screw terminal
Phillips screw terminal
Flat-bladed screw
terminal
Connector
None: DIN Track or screw mounting
F:
B:
B1:
P:
Terminals
Screw mounting
Phillips screw (3.5 mm) terminals (4 independent points)
Flat-bladed screw terminals (4 points with same common)
Connector terminals (4 independent points)
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
Rated voltage
G6B-4BND
G6B-47BND
G6B-48BND
G6B-4FB1ND
G6B-4FPND
Model

Related parts for G6B-4BND DC12

G6B-4BND DC12 Summary of contents

Page 1

... Longer operating life can be achieved by replacing the G6B-4@@ND with the G6B-1147P-FD-US. 2. Standard models are also available without relays mounted to the sockets. To obtain such terminals, replace the “G6B” portion of the model number with “P6BF.” For example, to order G6B-4BND with empty sockets, use model number P6BF-4BND. Also specify voltage specifications for models with operation indicators ...

Page 2

... Specifications ■ Ratings Coil Ratings (per G6B Relay) Rated voltage Rated current Coil resistance Must operate voltage Must release voltage Max. voltage Power consumption Note: 1. Rated current and coil resistance were measured at a coil temperature with a tolerance of 20%. 2. Operating characteristics were measured at a coil temperature ...

Page 3

... AC resistive load DC inductive load (L ms) DC resistive load Switching voltage (V) G6B-4@@ND 204 Terminal Relay Endurance 4,000 G6B-47@ (long life) 250 VAC resistive load 30 VDC resistive load 1,000 G6B-4@ (standard) 250 VAC resistive load 500 30 VDC resistive load 300 100 G6B-4@ (standard) G6B-47@ (long-life) 250 VAC inductive load (cos = 0 ...

Page 4

... Dimensions Note: All units are in millimeters unless otherwise indicated. Philip Screw Terminals G6B-4BND G6B-47BND G6B-48BND Note: G6B-4BND is shown in illustration (terminal numbers are incised). 78 max. Flat Screw Terminal G6B-4FB1ND 61 max. Eight, M3.5 Phillips head screws Connector Terminal G6B-4FPND 60 max. Eight, M3.5 Phillips ...

Page 5

... Accessories (Order Separately) Replacement Relays Applicable terminal relay G6B-4BND G6B-47BND Note: Relays cannot be replaced for G6B-48BND, which is mounted directly to boards. Relay Mounting Products Name Relay Removal Tool P6B-Y1 Short Bars G6B-4-SB Mounting Track PFP-100N PFP-50N PFP-100N2 End Plate PFP-M Spacer ...

Page 6

... If relay replacement is necessary, use the P6BF-4BND Terminal Sockets together with the G6B-1184P Mini Relays. P6BF-4BND Ter- minal Sockets are equipped with relay replacement sockets. Do not mount Relays that are different to one another in voltage. ...

Related keywords