MM4KP-AC200/220 Omron, MM4KP-AC200/220 Datasheet

no-image

MM4KP-AC200/220

Manufacturer Part Number
MM4KP-AC200/220
Description
RELAY
Manufacturer
Omron
Series
MMKr
Datasheet

Specifications of MM4KP-AC200/220

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
30mA
Coil Voltage
220VAC
Turn On Voltage (max)
176 VAC
Mounting Type
Socket
Termination Style
14 Pin Socketable
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
5A @ 220VAC
Control On Voltage (max)
176 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM4KPAC200220NC
Mechanically Latching Relays Based on the
MM Power Relay
• Low power consumption due to mechanical latch for economic
• Relays with mixed coil specifications can be produced (e.g., AC
• Operational response fast enough to enable pulse signal power
• Ambient operating temperature: –10°C to 55°C.
Ordering Information
Models Conforming to Auxiliary Power Relay Specifications
The MM4KP-JD and MM4XKP-JD satisfy the ratings of auxiliary relays provided in JEC-2500 (1987) standards for power protective relays specified
by the Japan Electromechanical Commission. Furthermore, the MM4KP-JD and MM4XKP-JD satisfy the ratings of multi-contact relays provided
in JEC-174D (1979) standards for power auxiliary relays.
These models work at operation level A specified by JEC-174D (1979) standards and the hot start of the relays is possible after the coils radiate
heat.
In accordance with JEC-2500 (1987) standards, the coil of each model withstands a 130% DC load or 115% AC load.
■ Available Models
Open Coils (with Solder Terminals)
Note: When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.
Standard
DC-switching
Conforming to auxiliary power
relay specifications
Standard
DC-switching
operation.
set coil and DC reset coil).
applications.
Latching Relay
MMK
Refer to Safety Precautions for All Relays.
Type
Example: MM2K, 6 VAC
Type
DPDT
3PDT
4PDT
DPDT+DPST-NO
DPDT
3PDT
4PDT
DPDT+DPST-NO
DPDT+DPST-NO
Contact form
DPDT
3P3T
DPDT+DPST-NC
DPDT
3P3T
DPDT+DPST-NC
Rated coil voltage
Contact form
MM2K
MM3K
MM4K
---
MM2XK
MM3XK
MM4XK
---
---
Solder terminals
MM2K
MM3K
MM4K
MM2XK
MM3XK
MM4XK
Relay model
Open structure
MM2KB
MM3KB
MM4KB
---
MM2XKB
MM3XKB
MM4XKB
---
---
Screw terminals
100/(110), 200/(220) VAC
12, 24, 48, 100/110, 200/220 VDC
100/(110), 200/(220) VAC
48, 100/110 VDC
200/(220) VAC
12, 24, 48, 100/110, 200/220 VDC
24, 100/110 VDC
200/(220) VAC
100/110 VDC
100/(110) VAC
100/110 VDC
Available rated voltage
MM2KP
MM3KP
---
MM4KP
MM2XKP
MM3XKP
---
MM4XKP
MM4KP-JD
MM4XKP-JD
Plug-in (octal pins)
CSM_MMK_DS_E_2_1
terminals
Cased
1

Related parts for MM4KP-AC200/220

MM4KP-AC200/220 Summary of contents

Page 1

... Models Conforming to Auxiliary Power Relay Specifications The MM4KP-JD and MM4XKP-JD satisfy the ratings of auxiliary relays provided in JEC-2500 (1987) standards for power protective relays specified by the Japan Electromechanical Commission. Furthermore, the MM4KP-JD and MM4XKP-JD satisfy the ratings of multi-contact relays provided in JEC-174D (1979) standards for power auxiliary relays ...

Page 2

... Contact form Relay model DP MM2KP 3P MM3KP 4P MM4KP DP MM2XKP 3P MM3XKP 4P MM4XKP 4P MM4KP-JD 4P MM4XKP-JD 3. Terminal Shape None: Solder B: Screw P: Plug-in Note: The suffix “JD” indicates models conforming to auxiliary power relay specifications. MMK Available rated voltage 100/(110), 200/(220) VAC 12, 24, 48, 100/110 VDC ...

Page 3

Accessories (Order Separately) Sockets Relay MM2(X)KP 11PFA MM3(X)KP 14PFA MM4(X)KP MM4(X)KP-JD 14PFA Mounting Brackets Contact form DPDT R99-03 (S KANAGU) FOR MM2K.611K 3PDT R99-03 (S KANAGU) FOR MM3K.612K 4PDT R99-03 (S KANAGU) FOR MM4K.613K Specifications ■ Coil Ratings Set ...

Page 4

Reset Coil Rated voltage (V) Rated current (mA 770 690 12 385 345 24 191 170 100/(110) 46 41/46 200/(220) 23 20/ 422 12 215 24 109 48 58 ...

Page 5

... A. The Relay will not turn OFF in this region. Use a switching current of 0 less when switching 125 VDC or more L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time must be considered in application and the circuit must be designed to ensure that an arc-breaking time not exceeded. Cased Relays: MM2KP, MM3KP, MM4KP Inductive load Resistive load (cosφ ...

Page 6

... Ambient temperature Operating: Ambient humidity Operating: Weight MM4KP-JD: MM4XKP-JD: Approx. 580 g Note: 1. The data shown above are initial values. 2. The electrical endurance was measured at an ambient temperature of 23°C. 3. This value was measured at a switching frequency of 60 operations per minute. Open or bifurcated-contact Relays ...

Page 7

Engineering Data ■ Standard Relays Maximum Switching Power Open Relays MM@K(B) AC resistive load AC inductive load (cosφ = 0.4) DC resistive load DC inductive load (L ms) Switching voltage (V) Endurance Curves Open Relays MM@K(B) 10,000 5,000 ...

Page 8

... Relays Conforming to Auxiliary Power Relay Specifications Maximum Switching Power MM4KP-JD AC inductive load AC resistive load cosφ = 0.4 DC resistive load DC inductive load L Switching voltage (V) Endurance Curves MM4KP-JD 220 VAC resistive load Inductive load cosφ = 0.4 24 VDC resistive load Inductive load L Switching current (A) Cased Relays MM@XKP 10,000 ...

Page 9

... Reset voltage Ambient temperature (°C) MM4KP DC Set voltage Number of Relays: 5 Reset voltage Ambient temperature (°C) Ambient Temperature vs. Coil Temperature Rise MM4KP 110 VAC (60 Hz) Number of Relays: 5 Contact carry current Set coil Reset coil Ambient temperature (°C) MM4KP DC Number of Relays: 5 Contact carry current ...

Page 10

Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Open Relays with Solder Terminals MM2(X)K, MM3(X)K, MM2(X)K MM4(X max. 22 ±0.2 44 max. MM2K Note: Connect the common (C) of MM@XK to positive (+). ■ ...

Page 11

... View) Standard Relays MM3KP MM4KP Note: Connect the common (C) to positive (+). Make sure that all common connections are the same in polarity. The markings of the common connections on the casing all show "+" but the polarity of the common connections can be either all negative or all positive. ...

Page 12

... Note: @PFA can be both track-mounted and screw-mounted. 123 max. Note: The MM4KP-JD is DPDT and 123 max. Note: The MM4XKP-JD is DPDT and DPST- NO. Make sure that all common connec- tions are the same in polarity. The mark- ings of the common connections on the casing all show " ...

Page 13

Safety Precautions Refer to Safety Precautions for All Relays. ■ Mounting Make sure that the Relay is free from iron powder or iron core, otherwise the iron dust may adhere to the Relay result the movable contact may ...

Page 14

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords