ZWS-70/CI/QS MICROSONIC, ZWS-70/CI/QS Datasheet

no-image

ZWS-70/CI/QS

Manufacturer Part Number
ZWS-70/CI/QS
Description
ULTRASONIC, BLOCK, 1M RNG, ANALOG
Manufacturer
MICROSONIC
Datasheet

Specifications of ZWS-70/CI/QS

Sensing Range
120 - 700mm
Frequency
300Hz
Operating Temperature Range
-25°C To +70°C
Sensing Range Distance
700mm
Sensing Range Max
1000mm
Sensor Input
Ultrasonic
Supply Voltage Dc Max
RoHS Compliant
zws-70/CI/QS / microsonic
zws-70/CI/QS
housing
operating range
design
operating mode
ultrasonic -specific
means of measurement
transducer frequency
blind zone
operating range
maximum range
angle of beam spread
resolution/sampling rate
reproducibility
accuracy
electrical data
operating voltage U
voltage ripple
no-load current consumption
type of connection
outputs
output 1
Balluff Sales: 0161 282 4700
g
f
e
d
c
mark for sensor comparison
1 x analogue 4-20 mA1,000 mm
detection zone
B
Page 1 of 2
120 - 700 mm
colloidal
analogue distance measurements
echo propagation time
300 kHz
120 mm
700 mm
1,000 mm
please see graphics detection zone
0.20 mm
± 0.15 %
20 - 30 V d.c., reverse polarity protection
± 10 %
4-pin M8 initiator plug
analogue output
current: 4-20 mA
2 % (temperature drift internal compensation)
30 mA
Seite 1 von 2
06.10.2009