IGW60T120 Infineon Technologies, IGW60T120 Datasheet
IGW60T120
Specifications of IGW60T120
Available stocks
Related parts for IGW60T120
IGW60T120 Summary of contents
Page 1
... Series ® and Fieldstop technology CE(sat) http://www.infineon.com/igbt/ T Marking Code CE(sat),Tj=25°C j,max 1.7V G60T120 150°C Symbol jmax IGW60T120 PG-TO-247-3 Package PG-TO-247-3 Value Unit 1200 V A 100 60 150 150 ± µs 375 W °C -40...+150 -55...+150 260 Rev. 2.4 Nov. 09 ...
Page 2
... 1200V , 25° 0° 20V 60A 25V 0V 60V 60A ≤10µ 5V 600V 25° IGW60T120 Max. Value Unit 0.33 K/W 40 Value Unit min. typ. max. 1200 - - V - 1.9 2 2.3 - 5.0 5 600 Ω - 3700 - pF - 180 - - 150 - - 280 - 300 - A Rev. 2.4 Nov. 09 ...
Page 3
... Symbol Conditions 0° 00V 60A 10Ω 180nH, σ =39pF E σ Energy losses include E “tail” and diode reverse recovery due to dynamic test circuit in Figure E. σ 3 IGW60T120 Value Unit min. typ. max 480 - - 4 5 9.5 - Value Unit min. typ. max 600 - - 130 ...
Page 4
... Figure 2. Safe operating area ( ≤150°C;V = 600V 80A 60A 40A 20A 0A 25°C 125° Figure 4. Collector current as a function of case temperature ( IGW60T120 t =3µs p 10µs 50µs 150µs 500µs 20ms DC 10V 100V 1000V - EMITTER VOLTAGE = 25°C, C =15V) GE 75°C 125°C ...
Page 5
... T , JUNCTION TEMPERATURE J Figure 8. Typical collector-emitter saturation voltage as a function of junction temperature (V = 15V IGW60T120 EMITTER VOLTAGE I =100A C I =60A C I =30A C I =15A C 0°C 50°C 100°C Rev. 2.4 ...
Page 6
... Dynamic test circuit in Figure 150°C -50°C 0° Figure 12. Gate-emitter threshold voltage as a function of junction temperature (I = 2.0mA) C =10Ω IGW60T120 15Ω 25Ω 35Ω 45Ω GATE RESISTOR G =150°C, J =600V, V =0/15V, I =60A max. typ. min. 50°C 100°C 150°C JUNCTION TEMPERATURE Rev ...
Page 7
... E * 5mJ on 150°C 400V V , COLLECTOR CE Figure 16. Typical switching energy losses as a function of collector emitter voltage (inductive load, T =10Ω Dynamic test circuit in Figure E) 7 IGW60T120 and E include losses 15Ω 25Ω 35Ω GATE RESISTOR G =150°C, J =600V, V =0/15V, I =60A and E include losses ...
Page 8
... GE 400A 300A 200A 100A 0A 14V 12V V GE Figure 20. Typical short circuit collector current as a function of gate- =25°C) emitter voltage IGW60T120 C iss C oss C rss 10V 20V - EMITTER VOLTAGE =0V MHz) 14V 16V 18V , - GATE EMITTETR VOLTAGE ≤ 600V, T ≤ 150°C) j Rev ...
Page 9
... I C 60A 60A 30A 30A 0us 1.5us 0.5us Figure 22. Typical turn off behavior = 150° Dynamic test circuit in Figure E) τ 7.98*10 -3 3.86*10 -4 4.44*10 -5 4.87* τ 100ms 9 IGW60T120 600V 400V 200V 0V 1us 1.5us t, TIME =15/0V, R =10Ω 150° Rev. 2.4 Nov. 09 ...
Page 10
... Power Semiconductors ® TrenchStop Series 10 IGW60T120 Rev. 2.4 Nov. 09 ...
Page 11
... Figure A. Definition of switching times Figure B. Definition of switching losses Power Semiconductors ® TrenchStop Series τ ( Figure D. Thermal equivalent circuit Figure E. Dynamic test circuit Leakage inductance L and Stray capacity C 11 IGW60T120 τ τ =180nH σ =39pF. σ Rev. 2.4 Nov. 09 ...
Page 12
... Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life. If they fail reasonable to assume that the health of the user or other persons may be endangered. Power Semiconductors ® TrenchStop Series 12 IGW60T120 Rev. 2.4 Nov. 09 ...