SI-LS42DMMHF BANNER ENGINEERING, SI-LS42DMMHF Datasheet

no-image

SI-LS42DMMHF

Manufacturer Part Number
SI-LS42DMMHF
Description
SI-LS42DMMHF SAFETY INTERLOCK
Manufacturer
BANNER ENGINEERING
Type
Interlockr
Datasheet

Specifications of SI-LS42DMMHF

Actuator Type
Flexible
Body Style
Rectangular
Contact Form
! NC, ! NO
Current, Rating
4 AAC
Function
Safety
Ip Rating
IP67
Material, Contact
Silver-nickel alloy
Number Of Poles
2
Number Of Positions
2
Standards
UL Listed, CSA Certified, CE Marked
Temperature Rating
–30 TO +80 °C
Voltage, Rating
24 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Printed in USA
otherwise defeat the protective function
of a safety switch. To do so may create
an unsafe situation which could lead to
serious injury or death.
WARNING . . .
Spare actuators must
NEVER be used to bypass or
®
• Choice of two locking mechanism types:
• Two solenoid voltages available:
• Choose either of two stainless steel actuator types:
• Actuator head rotatable in 90° increments and can be positioned for either horizontal
• Choice of four switching contact configurations (with actuator engaged):
NOTE:
Machine Safety Switches
SI-LS42 Series Locking Style Switch
- Spring lock with energized solenoid release
- Energized solenoid lock with spring unlock
- 24V ac/dc
- 24 to 48V dc or 24 to 230V ac
- Rigid in-line
- Flexible in-line
or vertical actuation
- 1 normally-open plus 1 normally-closed
- 2 normally-closed
- 2 normally-closed plus 1 normally-open
- 3 normally-closed
Positive opening safety contacts (IEC 60947-5-1) (not dependent upon springs)
Insulated device (IEC 60947-5-1)
actuator travel where the normally closed safety contact is fully open.
This symbol is used in the switching diagrams to identify the point in
07/06
Features
P/N 60099 rev. D

Related parts for SI-LS42DMMHF

SI-LS42DMMHF Summary of contents

Page 1

... Choose either of two stainless steel actuator types: - Rigid in-line - Flexible in-line • Actuator head rotatable in 90° increments and can be positioned for either horizontal or vertical actuation • Choice of four switching contact configurations (with actuator engaged normally-open plus 1 normally-closed ...

Page 2

... ISO 13849 (EN954-1). In addition, the user of Banner safety switches has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of Banner safety switches in any particular application are satisfied. Extreme care is urged that all legal requirements have been met and that all installations and maintenance instructions are followed ...

Page 3

... SI-LS42USH E1 + Actuator Contacts SI-LS42DSI 31 Rigid 21 SI-LS42USI 13 Solenoid Monitor SI-LS42DSI Contacts 41 SI-LS42USI E1 + Actuator Contacts 11 Rigid 21 31 SI-LS42DSJ Solenoid Monitor Contacts SI-LS42 Series Locking Style Switch Contact Configuration (Actuator Unlocked and Removed) Actuator Contacts Engaged Solenoid Monitor Contacts Disengaged Actuator Contacts 11 12 ...

Page 4

... In-Line SI-LS42UMMG 24-230V ac SI-LS42DMMGF 24V ac/dc SI-QM-SMFA Flexible 24-48V dc SI-LS42UMMGF In-Line 24-230V ac SI-LS42DMMH 24V ac/dc SI-QM-SSA 24-48V dc SI-LS42UMMH In-Line 24-230V ac SI-LS42DMMHF 24V ac/dc SI-QM-SMFA Flexible 24-48V dc SI-LS42UMMHF In-Line 24-230V ac SI-LS42DMMI 24V ac/dc SI-QM-SSA 24-48V dc In-Line SI-LS42UMMI 24-230V ac SI-LS42DMMIF 24V ac/dc SI-QM-SMFA ...

Page 5

... The mounting holes in the switch body accept M5 (#10) screws. There are four holes on a mounting pattern 124 mm (see dimension drawing of switch, page 10). See page 11 for dimensions of the actuator mounting holes. Position the switch, with its actuator fully engaged, at the mounting location and mark the mounting holes ...

Page 6

... Electrical Installation Access to Wiring Chamber The wiring chamber is accessed via the hinged door. Simply insert a flat-blade screwdriver, as shown in Figure 5, and pry gently down to open. Select the best wiring entrance and thread in the ½" NPSM conduit adapter (supplied), or the optional M20 x 1 ...

Page 7

... To provide a means of monitoring the contacts of both safety switches for contact failure, and to prevent the machine from restarting if either switch fails; and 2. To provide a reset routine after closing the guard and returning the safety contacts to their closed position. This prevents the controlled machinery from restarting by simply reinserting the safety switch actuators ...

Page 8

... Confirmation that the safety switch is not being used as an end stop, 4. Loosening of the switch or actuator mounting hardware, and 5. Verification that it is not possible to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. In addition, a Qualified Person should check for the following on a periodic schedule, ...

Page 9

... Engagement Radius Flexible actuators: 150 mm (6") Actuator Extraction Force 2000 Newtons (440 lbf) when locked Short Circuit Protection 6 amp Slow Blow, 10 amp Fast Blow. Recommended external fusing or overload protection. Mechanical Life 1 million operations Wire Connections 10 cage clamp elements 1.5 mm stranded max AWG Cable Entry M20 x 1.5 threaded entrance. Adapter supplied to convert M20 x 1.5 to ½ ...

Page 10

... See page 11 for actuator dimensions 30-40 mm (1.18"-1.58") 40-46 mm (1.6-1.8") 29.0 mm (1.14") M20 x 1.5 19.5 mm (0.76") Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 29.0 mm (1.14" ...

Page 11

... The flexible actuator mounting flange may be rotated 90° with respect to the actuator position. To rotate, push the flange in the direction of actuation, turn the flange either direction, and release to lock the flange in the new position; see the diagram above. SI-LS42 Series Locking Style Switch SI-QM-SMFA Flexible In-line Actuator 150 mm (6" ...

Page 12

... WARNING . . . Spare actuators must NEVER be used to bypass or otherwise defeat the protective function of a safety switch may create an unsafe situation which could lead to serious injury or death. WARRANTY:   Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period ...