DS26502LN Maxim Integrated Products, DS26502LN Datasheet - Page 95

no-image

DS26502LN

Manufacturer Part Number
DS26502LN
Description
Timers & Support Products E1-T1-J1-64KCC BITS Element 64kHz - G.70
Manufacturer
Maxim Integrated Products
Type
Clock Recoveryr
Datasheet

Specifications of DS26502LN

Supply Voltage (max)
3.46 V
Supply Voltage (min)
3.13 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Current
85 mA
Package / Case
LQFP-64

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS26502LN+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
DS26502LN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS26502LN+
Manufacturer:
DALLAS
Quantity:
20 000
14. LOOPBACK CONFIGURATION
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
HW
Mode
Bits 0, 1, 4 to 7: Unused, must be set = 0 for proper operation.
Bit 2: Remote Loopback (RLB). In this loopback, data received at RTIP and RRING will be looped back to the transmit LIU.
Received data will continue to pass through the receive side framer of the DS26502 as it would normally and the data from the
transmit side formatter will be ignored.
Bit 3: Local Loopback (LLB). In this loopback, data will continue to be transmitted as normal through the transmit side of the
DS26502. Data being received at RTIP and RRING will be replaced with the data being transmitted. Data in this loopback will
pass through the jitter attenuator if enabled.
0 = loopback disabled
1 = loopback enabled
0 = loopback disabled
1 = loopback enabled
7
0
0
LBCR
Loopback Control Register
20h
6
0
0
5
0
0
4
0
0
95 of 125
LLB
3
0
0
PIN 60
RLB
RLB
2
0
1
0
0
0
0
0

Related parts for DS26502LN