DLS-R-3-2/10 Cooper/Bussmann, DLS-R-3-2/10 Datasheet

no-image

DLS-R-3-2/10

Manufacturer Part Number
DLS-R-3-2/10
Description
Manufacturer
Cooper/Bussmann
Type
Dual Elementr
Datasheet

Specifications of DLS-R-3-2/10

Acting
Slow Blow
Voltage Rating (vac)
600V
Voltage Rating (vdc)
300V
Current Rating
3.2A
Mounting
Surface Mount
Product Depth (mm)
Not Requiredmm
Product Height (mm)
Not Requiredmm
Lead Free Status / RoHS Status
Not Compliant
Catalog Numbers
DLS-R-1
DLS-R-1flΩ ¡ º
DLS-R-2
DLS-R-2⁄Ω ™
DLS-R-2
DLS-R-3
DLS-R-3
DLS-R-3⁄Ω ™
DLS-R-4
DLS-R-5
DLS-R-6
DLS-R-6⁄Ω ¢
DLS-R-7
DLS-R-8
DLS-R-9
Catalog Symbol: DLS-R (600V)
Current-Limiting
Dual-Element, Time-Delay – 10 seconds (minimum) at
500% rated current
Voltage Rating: 600Vac (or less)
Self-Certified for 300Vdc
Interrupting Rating: 200,000A RMS Symmetrical
Agency Information:
UL Listed, Std. 248-12, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787
Dura-Lag
Dual-Element, Time-Delay Construction Grade Fuses
Class RK5 – 600 Volt
10-2-02
20,000A dc
CE logo denotes compliance with European Union Low Voltage Directive
Bussmann Application Engineering at 636-527-1270 for more information.
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
2
8
Ω ¡ º
Ω ¡ º
SB02295
DLS-R-10
DLS-R-12
DLS-R-15
DLS-R-17⁄Ω ™
DLS-R-20
DLS-R-25
DLS-R-30
DLS-R-35
DLS-R-40
DLS-R-45
DLS-R-50
DLS-R-60
DLS-R-70
DLS-R-80
DLS-R-90
DLS-R-100
DLS-R-110
DLS-R-125
DLS-R-150
DLS-R-175
DLS-R-200
DLS-R-225
DLS-R-250
DLS-R-300
DLS-R-350
DLS-R-400
DLS-R-500
DLS-R-600
Dimensional Data
Dimensions (inches)
Ampere Ratings
110-200
225-400
450-600
General Information:
• Designed for contractor needs.
• Protects industrial equipment and large motors.
• Recommended for ac power distribution system mains,
• Industry standard time-delay of 10 seconds at 5 times
Carton Quantity and Weight
Ampere
Ratings
⁄Ω ¡ º–30
35–60
70–100
110–200
225–400
450–600
*Weight per carton.
70-100
⁄Ω¡ºA to 30A
feeders and branch circuits.
the fuse rating.
5" ( 0.31)
.81" ( 0.008)
Carton
Qty.
10
10
5
1
1
1
11.63 (± 0.094)
13.38 (± 0.094)
7.88 (± 0.062)
9.63 (± 0.062)
Recommended fuseblocks for
Class R 600V fuses
See Data Sheet: 1111
A
A
35A to 60A
5.5" ( 0.31)
Lbs.
1.62
3.00
2.20
1.10
2.36
3.44
1 –600 Amps
Bussmann
1.16 (± 0.008)
1.66 (± 0.008)
2.38 (± 0.008)
2.88 (± 0.008)
Weight*
DLS-R
Data Sheet: 1022
1.06" ( 0.008)
Form No. DLS-R
B
Page 1 of 3
0.729
1.35
1.0
0.5
1.1
1.5
Kg.
®
B

Related parts for DLS-R-3-2/10

DLS-R-3-2/10 Summary of contents

Page 1

... Dura-Lag Dual-Element, Time-Delay Construction Grade Fuses Class RK5 – 600 Volt Catalog Symbol: DLS-R (600V) Current-Limiting Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Voltage Rating: 600Vac (or less) Self-Certified for 300Vdc Interrupting Rating: 200,000A RMS Symmetrical 20,000A dc Agency Information: UL Listed, Std. 248-12, Guide JDDZ, File E4273 CSA Certified, C22 ...

Page 2

... Dual-Element, Time-Delay Construction Grade Fuses Class RK5 – 600 Volt Time-Current Characteristic Curves–Average Melt 100 .01 RMS SYMMETRICAL CURRENT IN AMPERES 10-2-02 SB02295 AMPERE RMS SYMMETRICAL CURRENT IN AMPERES RATING PROSPECTIVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPERES Bussmann ® DLS-R 1 –600 Amps Form No. DLS-R Page Data Sheet: 1022 ...

Page 3

... Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 10-2-02 SB02295 Bussmann ® DLS-R 1 –600 Amps Form No. DLS-R Page Data Sheet: 1022 ...