8432180000 Weidmuller, 8432180000 Datasheet

no-image

8432180000

Manufacturer Part Number
8432180000
Description
WTS4 PT100/2,V,0-10V
Manufacturer
Weidmuller
Datasheet

Specifications of 8432180000

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Analogue Signal Processing
156

Related parts for 8432180000

8432180000 Summary of contents

Page 1

Analogue Signal Processing 156 ...

Page 2

Analogue Signal Processing The problem The real world can be measured in many ways, for example, via temperature, humidity, air pressure and so forth. The parameters of these different physical qualities change continuously. Elements that monitor statuses and changes in ...

Page 3

Analogue Signal Processing 2-way-isolation separates the signals galvanically and decouples the measurement circuits doing it eliminates potential differences caused by long cable lengths and common reference points. Furthermore, the galvanic isolation offers protection against destruction by overvoltage, and ...

Page 4

Design Overview Mini Coupler / Mini Conditioner WAVESERIES RS profiles DK Mini Coupler / MCZ Mini Conditioner Extensive range of electronic functions in terminal format Pluggable cross-connections with mini conditioners Mini couplers with screw-in cross-connection combs Mini couplers with screw ...

Page 5

Selection Table of Functions Function Areas of application DC signal conditioners Signal conditioning, signal isolation, suppression of mass loops Motor current limitation, pressure alarm, direct disconnection of connected modules, safety function PT100 signal conditioners Temperature monitoring, noise rejec- tion, electrical ...

Page 6

Selection Table Function Input Output 0…20mA 0…20mA DC/DC 0…20mA 0…20mA 0…20mA 0…20mA 0…20mA 0…20mA 0…20mA 0…20mA 0…20mA 0…20mA 0…20mA 4…20mA 0…20mA 4…20mA 0…20mA 4…20mA 0…20mA 0…10V 0…20mA 0…10V 0…20mA 0…10V 4…20mA 0…20mA 4…20mA 0…20mA 4…20mA 0…20mA 4…20mA 4…20mA 4…20mA 4…20mA ...

Page 7

... Screw/ 185 8560740000/ tens. clamp 8560750000 12.5 Screw/ 186 8432210000/ tens. clamp 8432220000 12.5 Screw/ 186 8432180000/ tens. clamp 8432190000 6 Tens. clamp 165 8425720000 12.5 Screw/ 187 8432150000/ tens. clamp 8432160000 12.5 Screw/ 187 8432090000/ tens. clamp 8432130000 12 ...

Page 8

Selection Table Function Input Output 8-bit 0…20mA DA convert. 8-bit 4…20mA 8-bit 0…10V 8-bit 12-bit 0…20mA 12-bit 4…20mA 12-bit 0…10V 12-bit Current 0…1/5/10 Aac 1) monitoring 0…1/5/10 Aac 1) 0…20/40/60 Aac 1) 0…20/40/60 Aac 1) 0…1/5/10 Aac 2) 0…1/5/10 Aac ...

Page 9

Passive Isolator This module is a reasonably priced passive separator for galvanically separating standard 0.4...20 mA signals. It draws its power from the measurement signal and requires no further auxiliary power. The measurement signal is transmitted 1:1. The module is ...

Page 10

RTD Thermocouple Conditioners • for 2 and 3 wire sensors The temperature module converts measurement values from a PT 100 into analogue measure- ment signals. The module supplies the sensor with power. The module is distinguished by its accuracy and ...

Page 11

Frequency Signal Conditioners • Tension clamp connection • LED-Display • Adjustable frequency output The option of reading-in the analogue signals from the field via counter inputs of the control is made possible by converting the analogue sig- nals in to ...

Page 12

Frequency Signal Conditioners • Screw connection • LED-Display Adjustable frequency output • For EMC reasons, frequency processing mod- ules must be used in conjunction with shielded cables. This measure prevents interference of analogue and frequency signals by other signal cables ...

Page 13

Frequency Signal Conditioners • Screw connection • LED-Display • Adjustable frequency output • multiplex capable For EMC reasons, frequency processing mod- ules must be used in conjunction with shielded cables. This measure prevents interference of analogue and frequency signals by ...

Page 14

Monitoring Revolutions If only one revolution limit evaluated, the potentiometer for f must be set to end stop max or the potentiometer for f to left stop. Then min only the other is in each case active ...

Page 15

Preprocessing Logic • Screw connection • logic function and time function combined • individually programmable (further functions on request) Block diagram Ordering data for TS 32 for TS 35 Technical data Logical function Number of inputs Input nominal level Overload ...

Page 16

Remark: The module is programmed according to customers specifications inputs can be linked with various logic and timer functions, e.g.: AND, OR, EXOR, NAND, NOR, EXNOR, delay elements, etc. The output is either low or high active. ...

Page 17

Threshold Monitoring Current sensor • Screw connection • Mounts onto on mounting rail • Wide spectrum of functions • In part, individually adjustable Block diagram/settings S1 S2 DIP switch on on 10…100 mV on off 30 mV…1 V off X ...

Page 18

Threshold Monitoring The Setpoint Controller allows cost effective units to be built for monitoring analogue signals. An upper and lower limit value, which covers the en- tire signal range, can be set by the user via 2 potentiometers. The respective ...

Page 19

Passive Isolator DC/DC WAVE DC/DC ANALOG input loop powered galvanic isolation 1-, 2-channel versions low power consumption safe separation Approvals: Block diagram Ordering data Screw connection 1 channel Tension clamp connection 1 channel Screw connection 2 channel Tension clamp connection ...

Page 20

DC/DC-Signal Conditioners WAVE DC/DC ANALOG voltage supply on output side 2-way-isolation analogue signal conditioning galvanic isolation between input/output signal Input loop powered cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* ...

Page 21

DC/DC-Signal Conditioners WAVE DC/DC ANALOG voltage supply on both sides 2-way-isolation analogue signal conditioning galvanic isolation between input/output signal cross-connectable voltage supply via cross-connectorss Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input signal Input ...

Page 22

DC/DC Signal Conditioners WAVE DC/DC ANALOG voltage supply on both sides 2-way-isolation analogue signal conditioning galvanic isolation between input/output signal cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input signal ...

Page 23

DC/DC Signal Conditioners WAVE DC/DC ANALOG 3-way-isolation analogue signal conditioning indication LED cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data** Input signal Input current max Input resistance Output signal Load ...

Page 24

DC/DC Signal Conditioners WAVE DC/DC ANALOG 3-way-isolation analogue signal conditioning indication LED cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data Input signal Input current max Input resistance Output signal Load ...

Page 25

DC/DC Signal Conditioners WAVE DC/DC ANALOG 3-way-isolation analogue signal conditioning indication LED cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input signal Input voltage max. Input resistance Output signal Load ...

Page 26

DC/DC Signal Conditioners WAVE DC/DC 20 kHz ANALOG 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data** Input signal Input current max Input ...

Page 27

DC/DC Signal Conditioners WAVE DC/DC 20 kHz ANALOG 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input signal Input current max Input ...

Page 28

DC/DC Signal Conditioners WAVE DC/DC 20 kHz ANALOG 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input signal Input voltage max. Input ...

Page 29

DC/DC Signal Conditioners WAVE DC/DC 20 kHz ANALOG 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input signal Input voltage max. Input resistance ...

Page 30

DC/DC Signal Conditioners (Configurable) WAVE PRO DC/DC ANALOG universally adjustable via DIP switch adjustment help via Internet 3-way-isolation voltage supply from 20 - 230 V ac/dc low power loss adjustable transmission frequency indication LED Approvals: Block diagram Ordering data Screw ...

Page 31

... Please indicate additional output signal of current output 186 PT100/2 PT100/2 0(4) ... ... 10 V Type Cat. No. Type WTS4 PT100/2 C 8432210000* WTS4 PT100/2 V 8432180000* WTZ4 PT100/2 C 8432220000* WTZ4 PT100/2 V 8432190000* PT100/2 / 0(4) ... 20 mA PT100 ... 10 V PT100/2-wire PT100/2-wire -200 ... +800 °C -200 ... +800 °C 1. ...

Page 32

RTD Signal Conditioners WAVE RTD ANALOG 3-wire technology configurable temperature range -200 °C ... +800 °C configurable output current range 0 ... ... 20 mA cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw ...

Page 33

RTD Signal Conditioners WAVE RTD ANALOG 2-, 3- and 4-wire technology configurable temperature range -200 °C ... +800 °C configurable output current range 0 ... ... 20 mA cross-connectable voltage supply via cross-connectors Approvals: Block diagram ...

Page 34

RTD-Signal Isolating Transformer (Configurable) WAVE PRO RTD ANALOG measurement from PT 100, Ni 100, R, potentiometer univerally adjustable via DIP switch 3-way-isolation status LED linearization cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection ...

Page 35

Thermo-Signal Conditioners WAVE Thermo ANALOG thermocouples configurable temperature range -200 °C ... +1820 °C no adjustment necessary cold junction compensation configurable output signal cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering ...

Page 36

Thermo Signal Isolating Transformers (Configurable) WAVE PRO Thermo ANALOG 3-way-isolation thermocouples configurable temperature range -200 °C ... +1820 °C no adjustment necessary cold junction compensation configurable output signal cross-connectable voltage supply via ...

Page 37

Adjustment Help WAVE TOOL The adjustment help – WAVE – TOOL enables quick and uncomplicated configuration of WAVE PRO DC, ANALOG WAVE PRT RTD, ANALOG WAVE PRO THERMO. ANALOG Menu for selecting the functions For configuring the current/voltage isolating transformer ...

Page 38

193 ...

Page 39

WAVE CONTROL Current monitoring Monitoring flows of currents enables a constant control of individual devices and installation components. Discrepancies or disruptions arising in the electrical circuit can easily be eval- uated as breakdowns. Targeted recti- fying procedures can be taken. ...

Page 40

WAVE CONTROL Less wiring costs thanks to cross- connections Very good marking options Fast commissioning – pluggable replacement PCBs Connection technology – screw or tension clamp via socket block Tool-free mounting Coding elements in the connections – false plugging not ...

Page 41

Current Monitoring WAVE CONTROL current ranges adjustable via DIP switch cross-connectable voltage supply via cross-connectors selectable hysteresis selectable working and closed-circuit current principle Approvals: Block diagram Ordering data Screw connection Tension clamp connection Technical data* Input Input current Input frequency ...

Page 42

Current Monitoring WAVE CONTROL input and output range adjustable via DIP switch no calibration required cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Technical data* Input Input current Input frequency Accuracy Measuring principle ...

Page 43

Current Monitoring WAVE CONTROL input and output range adjustable via DIP switch no calibration required true TRMS value measurements hall sensor measurement method Approvals: Block diagram Input / Output configurable Ordering data Screw connection Tension clamp connection Technical data* Input ...

Page 44

Current Monitoring WAVE CONTROL input and output range adjustable via DIP switch no calibration required cross-connectable voltage supply via cross-connectors true TRMS value measurements hall sensor measurement method Approvals: Block diagram Ordering data Screw connection Tension clamp connection Technical data* ...

Page 45

Current Monitoring • For AC/DC • With and without adjustable switching threshold • Opto-coupler output This series is particularly suitable for monitoring small currents from The adjustable switching threshold activates optionally one relay-or opto-cou- pler ...

Page 46

SMSI AC O With adjustable switching threshold up to 250 2.5 A Type Cat. No. Type Cat. No. SMSI 0. 1156460000 SMSI 2 1157360000 10 V…250 Vac 10 V…250 Vac 300 mA 2.8 ...

Page 47

Current Monitoring • For AC/DC • Adjustable switching threshold • Relay output Ordering data Technical data Measurement circuit voltage Max. permissible current in measurement circuit Rated consumption ~ (VA) Voltage drop at input Adjustable switching threshold Hysteresis between turn-on and ...

Page 48

Current Monitoring Ordering data Technical data Measurement circuit voltage Max. permissible current in measurement circuit Rated consumption ~ (VA) Voltage drop at input Adjustable switching threshold Hysteresis between turn-on and turn-off point Activation time tA Reaction time tR Recovery Output ...

Page 49

Voltage Monitoring • Voltage monitoring from 18 to 299 V • One and three phase version • Adjustable switching threshold Adjustable threshold switching on switching off Hysteresis Relay 204 Block diagram/ timing diagram Ordering data Technical data Voltage monitoring range ...

Page 50

SMSU 110 R SMSU 220 R Type Cat. No. Type Cat. No. SMSU 110 R 1157760000 SMSU 220 R 1157860000 83 Vdc…121 Vdc or 165 Vac…253 Vac/ Vac…121 Vac/50 Hz < 1.6 W – < 1.5 W < ...

Page 51

Movement and Rotational Speed Monitoring Block diagram Ordering data Description Technical data Operating voltage Initiator type/initiator voltage Output voltage Continuous current Max. switching capacity (resistive load) Contact Contact material Mechanical service life Time range Coordination of insulation to VDE DIN ...

Page 52

Namur Switch Amplifiers Block diagram Ordering data Description Technical data Input voltage Initiator type/initiator voltage Output voltage, -current Continuous current Max. switching capacity (resistive load) Contact Contact material Mechanical service life Ambient temperature Coordination of insulation to VDE DIN 0160, ...

Page 53

Set Point Generator EMA / SW 24 • Set point generator • switchable –10.5 V/+10.5 V Set point 1 or set point 2 can be switched to the module’s output as required. The changeover is performed safely separated via the ...

Page 54

209 ...

Page 55

Analogue/Digital Converters Hold function (H): Enable function (E): The converter can, for The Enable circuit (E) example, by means of the allows several converters, hold function ( input card of a matched to the cycle ...

Page 56

Digital/Analogue Converters Ordering data Technical data Input signal Max. input voltage Max. input current Input resistance Prefix Resolution Output signal Output current Offset Load resistance Transmission error Conversion time Supply Connection arrangement Storage temperature Operating temperature EMC EN 50 ...

Page 57

Analogue/Digital Converters Hold function (H): The converter can, for example, by means of the hold function (H) be matched to the cycle time of a PLC. Holding and release of the conversion. The Hold input (H) is internally connected ...

Page 58

Digital/Analogue Converters Ordering data Technical data Input signal/measurement range Max. input voltage Input current, I nom Input resistance Prefix Resolution Output signal Output current Output level Load resistance Transmission error Conversion time Temperature coefficient Supply Max. power loss Connection ...

Related keywords