611073-000 Tyco Electronics, 611073-000 Datasheet - Page 552

no-image

611073-000

Manufacturer Part Number
611073-000
Description
Connector Accessories Adapter Aluminum Alloy Olive Drab Cadmium Over Electroless Nickel
Manufacturer
Tyco Electronics
Type
Adapterr
Datasheet
9-70
Specifications/Approvals
Product Dimensions (Nominal)
Note: All values are nominal.
Product Characteristics
Small, Lightweight Coaxial
Cables
Properties (per SCD)
*See Raychem specification WCD-1200 for details.
Catalog 1654025
Revised 12-04
www.tycoelectronics.com
5012E1339
5012M1612
5024A1311
5026D1027
5030A1317
5030A1424
7520A1311
7524A1311
7528H1424
7530A1317
7530H1424
9522A1311
9527J1528
9530H1014
Physical
Tensile (min.)
Elongation (min.)
Electrical
Dielectric withstand (min.)
Velocity of propagation (nom.)
Dielectric constant
Physical
Tensile (min.)
Elongation (min.)
Temperature (max.)
Flammability*
Fluid category*
Part No.
Product
Typical
Impedance
(ohms)
50
50
50
50
50
50
75
75
75
75
75
95
95
95
Dimensions are in millimeters
and inches unless otherwise
specified. Values in brackets
are U.S. equivalents.
100.4 [30.6]
Capacitance
98.4 [30.0]
82.0 [25.0]
83.7 [25.5]
88.9 [27.1]
90.2 [27.5]
56.1 [17.1]
56.4 [17.2]
54.5 [16.6]
60.4 [18.3]
57.4 [17.5]
44.3 [13.5]
44.3 [13.5]
44.3 [13.5]
(pF/ft)
pF/m
General
Electrical
*Temperature rating varies depending on materials used in specific construction.
Controlled Electrical Cables
Cheminax Coaxial Cables
(1000 psi)
Thermorad
(2000 psi)
Rayfoam L
13.6 MPa
Method C
6.8 MPa
1000 V
[257°F]
125°C
250%
50%
78%
1.65
C
Typical Value of Dielectric Material
Attenuation
at 400 MHz
(dB/100 ft)
50.3 [15.3]
63.7 [19.4]
97.5 [29.7]
94.5 [28.8]
44.0 [13.4]
58.8 [17.9]
58.1 [17.7]
44.3 [13.5]
dB/100m
14.8 [4.5]
16.1 [4.9]
20.0 [6.1]
31.8 [9.7]
19.7 [6.0]
31.8 [9.7]
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Rayfoam H
(5000 psi)
Method B
(600 psi)
4.1 MPa
SPEC 55
34 MPa
[392°F]
1000 V
200°C
50%
50%
78%
1.65
A
Cheminax cables
(Continued)
2.26 [.089]
2.26 [.089]
0.62 [.025]
0.48 [.019]
0.30 [.012]
0.30 [.012]
1.02 [.040]
0.62 [.025]
0.32 [.013]
0.30 [.012]
0.30 [.012]
0.79 [.031]
0.43 [.017]
0.30 [.012]
Series
Conductor Range
Operating Temperature Range*
Impedance range
Dielectric constant
Velocity of propagation
Conductor
Diameter
Type Value of Jacket Material
A
(1800 psi)
(3000 psi)
12.2 MPa
20.4 MPa
Method B
Rayolin F
FlexLine
1000 V
[392°F]
200°C
200%
100%
67%
2.2
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
7.24 [.285]
6.07 [.239]
1.70 [.067]
1.27 [.050]
0.79 [.031]
0.86 [.034]
4.57 [.180]
1.37 [.054]
1.35 [.053]
1.30 [.051]
5.51 [.217]
2.84 [.112]
1.83 [.072]
2.82 [.111]
A
Dielectric
Diameter
B
7.98 [.314]
6.60 [.260]
2.18 [.085]
1.70 [.067]
1.12 [.044]
1.19 [.047]
3.25 [.128]
1.73 [.068]
1.73 [.068]
6.05 [.238]
3.18 [.125]
2.26 [.089]
5.11 [.201]
1.78 [.07]
Diameter
Shield
13.6 MPa
(2000 psi)
Method B
[392°F]
C
200°C
200%
FEP
Raychem
A
1200
10.24 [.403]
7.06 [.278]
2.67 [.104]
2.21 [.087]
1.57 [.062]
1.60 [.063]
6.12 [.241]
3.86 [.152]
2.13 [.084]
7.32 [.288]
3.58 [.141]
2.62 [.103]
Diameter
South America: 55-11-3611-1514
Japan: 81-44-900-5102
Singapore: 65-4866-151
UK: 44-1793-528171
2.29 [.09]
2.03 [.08]
Jacket
12 AWG to 30 AWG
-65°C to 200°C [-85°Fto 392°F]
50 ohms to 125 ohms
1.65–2.3
67%–80%
D
(1200 psi)
Method B
8.2 MPa
Zerohal
[257°F]
125°C
150%
C
162.2 [109.0]
(lb/1000ft)
74.5 [50.1]
43.2 [29.0]
19.2 [12.9]
55.1 [37.0]
19.2 [12.9]
Weight in
13.1 [8.8]
11.8 [7.9]
11.8 [7.9]
kg/km
4.5 [3.0]
5.7 [3.8]
8.9 [6.0]
8.3 [5.6]
8.5 [5.7]
(2500 psi)
27.2 MPa
Method B
SPEC 44
[302°F]
150°C
150%

Related parts for 611073-000