MS27467T15B35P Conesys, MS27467T15B35P Datasheet - Page 13

no-image

MS27467T15B35P

Manufacturer Part Number
MS27467T15B35P
Description
Conn MIL-DTL-38999 Circular PIN 37 POS Crimp ST Cable Mount 37 Terminal 1 Port
Manufacturer
Conesys
Type
MIL-DTL-38999 Circularr
Datasheet

Specifications of MS27467T15B35P

Gender
PL
Termination Method
Crimp
Mounting
Cable Mount
Body Orientation
Straight
Contact Installation
Instructions
Crimping Contacts
1. Select the appropriate crimp tool and ensure that the
2. Cycle the tool to be sure the indentors are open.
3. Determine the correct selector setting for the wire size
4. Place the contact, mating end first, into the tool.
5. Insert the stripped wire into the hollow end of the
6. Close the tool completely to crimp. Unless the tool is
7. Remove the crimped contact from the tool. Check the
Insertion of Contacts
1. Before inserting the contacts, unscrew the accessories
2. To assist insertion of contacts, lubricate insulator
For coax and twinax contacts refer to instructions that are supplied with contacts.
www.conesys.com
22M
Size
22D
22
20
20
12
proper crimp head positioner is used.
from the data plate on the positioner (turret head
assembly) and set the selector knob on the crimp tool
to match.
contact. Be sure the wire is inserted as far as it will go.
closed completely, the tool will not release the contact.
inspection hole to verify that the wire is fully inserted.
(clamps, backshells or adapters) from rear of plug or
receptacle. Slide the hardware over the wire bundle in
the proper order for reassembly after all the contacts
are inserted.
(grommet) cavities with isopropyl alcohol. Alcohol will
evaporate and will not leave a conductive film. Caution:
Never use any lubricant other than isopropyl alcohol.
MIL-DTL-38999
Contact Installation Instructions
Series I
M39029/58-360
M39029/58-361
M39029/58-362
M39029/58-363
M39029/58-364
M39029/58-365
Pin Contact
Socket Contact
M39029/56-348
M39029/56-349
M39029/56-350
M39029/56-351
M39029/56-352
M39029/56-353
Basic Crimp Tool
M22520/2-01
M22520/2-01
M22520/2-01
M22520/1-01
M22520/2-01
M22520/1-01
M22520/1-01
14
3. Place the correct insertion tool on the contact so that the
4. Beginning with a center cavity, insert the contact into the
5. Remove tool and check the face of the connector for
Completion
After all the cavities have been filled, slide the hardware back
into position on the connector and tighten.
Extraction of Contacts (Rework)
1. Slide the hardware back over the wire bundle.
2. Select the appropriate tool. Place the wire into the
3. Slowly slide the extraction tool down wire into the
M22520/1-04 Yellow
M22520/1-04 Blue
M22520/1-04 Red
wire runs along the groove in the tool. (Tool tip will butt
against the shoulder.) Hold the plug or receptacle body
firmly.
insulator with a slow, even pressure until the contact
snaps into position. Make sure the contact and tool are
held perpendicular to the face of the insert during the
contact installation or the grommet could be damaged.
4.1 If contacts are not inserted all the way prior to
proper contact installation. Proper installation may also
be checked by pulling back lightly on the wire to make
sure the contact is properly seated.
extraction tool of the pin or socket.
contact cavities until the tool tip bottoms against the
contact shoulder, expanding the clip retaining tines. Hold
the wire firmly in the tool and pull the wired contact and
tool straight out of the rear of the insulator.
Pin Positioner
M22520/2-09
M22520/2-09
M22520/2-09
M22520/2-10
removing insertion tool, do not try to reinsert the
insertion tool. Instead, remove the contact and try
again; otherwise reinserting the insertion tool may
damage the inside of the contact cavity.
M22520/1-04 Yellow
Socket Positioner
M22520/1-04 Blue
M22520/1-04 Red
M22520/2-07
M22520/2-07
M22520/2-07
M22520/2-10
sales
Insertion/Removal Tool
@
M81969/14-01
M81969/14-01
M81969/14-01
M81969/14-10
M81969/14-03
M81969/14-04