DSP6012 TDK Corporation, DSP6012 Datasheet

no-image

DSP6012

Manufacturer Part Number
DSP6012
Description
AC/DC Power Supply Single-OUT 12V 4.5A 54W
Manufacturer
TDK Corporation
Datasheet

Specifications of DSP6012

Input Voltage
90 to 264 V
Output Voltage
12 V
Maximum Output Current
4.5 A
Number Of Outputs
1
Maximum Output Power
54 W
Efficiency
84(Typ) %
Input Frequency
47 to 63 Hz
Operating Temperature
-25 to 71 °C
Note 1:
Note 2:
ITEMS
AC Input Voltage range
Input Frequency
DC Input Voltage range
Inrush Current (115 / 230VAC)
Power Factor
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple and Noise (20MHz BW)
Overcurrent Protection (Typ)
Overvoltage Protection
Hold Up Time (115VAC input)
LED Indicators
Operating Temperature
Temperature Coefficient
Storage Temperature
Operating Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (Operating)
Shock (Operating)
Safety Agency Approvals
Immunity
Conducted & Radiated EMI
Weight (Typ)
Size (WxHxD)
Case material
Warranty
Specifications
DSP Series
7.5W to 100W Low Profile
Din Rail Mount Power Supplies
• Low 56mm Profile
• Wide Range AC
• Convection cooled
DSP Features and Benefits
Features
For DSP100-24/C2 Ripple & Noise measured with Vin 115- 230 Vac
Excludes Models: DSP60-5, DSP60-12, DSP100-12, DSP100-15, DSP100-24
MODEL
%/°C
VDC
VAC
mm
mV
Hz
ms
yrs
%
%
%
A
V
g
-
-
-
-
-
-
-
-
-
-
-
EN55022 class B
18 x 91 x 55.6
IEC60068-2-6 (Mounting by rail: Random wave, 100-500Hz, 2G, ea. along X, Y, Z axes 10min/cycle, 60 min)
15 / 30A
DSP10
60
IEC60068-2-27 (Half sine wave, 4G, 22ms, 3 axes, 6 faces, 3 times for each face)
DSP Series
90 - 264VAC, Class II double insulated (No ground connection required)
110 - 160%, fold forward under short circuit (DSP100-24/C2 102-108%)
Benefits
• Fits into wall mounted cabinets
• Global use with no input selector switches
• No system fan required
UL1310 Class 2
-25 to +71°C (Derate linearly 2.5%/°C from 55 to 71°C)
>100M at 25°C & 70%RH, Input to Ground 500VDC
Green LED = On, Red LED = DC Output Low
53 x 91x 55.6
Meets EN61000-3-2, EN61000-3-3
EN61000-4-2, -3, -4, -5, -6, -8 & -11
25 / 50A
DSP30
Input to Output 3kVAC for 1 min.
• Low Profile for Building Automation
• 5V to 24V Outputs
• Wide Range AC Input
• -25°C to +71°C Operation
• Convection Cooled
• UL1310 Class 2
• Class II Double Insulation
Key Market Segments & Applications
Building Services
Automation:
20 - 95% RH (non condensing)
(2)
200
, UL508 Listed, UL60950-1, EN60950-1, CE
±1% of Nominal
See Model Selector
-25°C to +85°C
120 - 370VDC
120 - 145%
±0.02%/°C
Convection
47 - 63Hz
50mV
Plastic
1%
1%
2
(1)
EN55022 class A
71 x 91 x 55.6
30 / 60A
DSP60
Alarms and Security,
Access and Fire Safety Systems,
Lighting and Environment Control
Systems.
250
90 x 91 x 56.8
DSP100
30 / 60A
320
1

Related parts for DSP6012

DSP6012 Summary of contents

Page 1

DSP Series 7.5W to 100W Low Profile Din Rail Mount Power Supplies DSP Features and Benefits Features • Low 56mm Profile • Wide Range AC • Convection cooled Specifications MODEL ITEMS AC Input Voltage range VAC Input Frequency Hz DC ...

Page 2

Model Selector Model Voltage (V) DSP10-5 5 DSP30-5 5 DSP60-5 5 DSP10-12 12 DSP30-12 12 DSP60-12 12 DSP100-12 12 DSP10-15 15 DSP30-15 15 DSP60-15 15 DSP100-15 15 DSP10-24 24 DSP30-24 24 DSP60-24 24 DSP100-24/C2 24 DSP100-24 24 Outline Drawing DSP10 ...

Page 3

Outline Drawing DSP30 Series mm [inch] 53. Outline Drawing DSP60 Series mm [inch] 71. Outline Drawing DSP100 Series mm [inch] 89 14.20 ...

Page 4

TDK-LAMBDA EMEA TDK-Lambda France SAS ZAC des Delaches BP 1077-Gometz-le-Chatel 91940 Les Ulis France Tel: + Fax: + france@fr.tdk-lambda.com www.fr.tdk-lambda.com Italy Sales Office Via dei Lavoratori 128/130 20092 Cinisello Balsamo ...

Related keywords