LPS48 Astec Power, LPS48 Datasheet

no-image

LPS48

Manufacturer Part Number
LPS48
Description
AC/DC Power Supply Single-OUT 48V 1.2A 55W 10-Pin
Manufacturer
Astec Power
Datasheet

Specifications of LPS48

Input Voltage
85 to 264 V
Output Voltage
48 V
Maximum Current Rating
1(rms) A
Maximum Output Current
1.2 A
Number Of Outputs
1
Maximum Output Power
55 W
Efficiency
70(Typ) %
Input Frequency
47 to 440 Hz
Operating Temperature
0 to 50 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPS48D12/625J
Quantity:
726
Part Number:
LPS48S051300J
Manufacturer:
PACKAGED
Quantity:
28
Special Features
• Universal input
• 3” x 5” footprint
• Less than 1U high
• Remote sense
• Terminal block option (-T)
• Built-in EMI filter
• Low output ripple
• Adjustable output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety
LPS40 Series
40 Watts
Total Power:
Input Voltage:
# of Outputs:
UL
CSA CSA 22.2-234 Level 3
NEMKO EN 60950/EMKO-TUE
CB
CE Mark (LVD)
UL60950
E132002
LR53982C
P94100375 (74-sec)203
1119, 1125, 1126, 1127
Certificate and report
40 - 55 Watts
85 - 264 VAC
120 - 300 VDC
Single
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI filter:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 5 V output; 5.7 to 6.7 VDC. Other outputs 10% to 25% above nominal
Remote sense:
85 - 264 VAC; 120 - 300 VDC
47 - 440 Hz
< 18 A peak @ 115 VAC; < 36 A peak @ 230 VAC, cold start @ 25 °C
1 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 class B conducted
< 0.5 mA @ 50/60 Hz, 264 VAC input
40 W for convection; 55 W with 30CFM forced air
-5, +10% minimum
20 ms @ 40 W load, 115 VAC nominal line
Short circuit protection on all outputs
Case overload protected @ 110 -145% above peak rating
output
Compensates for 0.5 V lead drop minimum
Will operate without remote sense connected
Reverse connection protected
Embedded Power for
Business-Critical Continuity
Rev. 7.8.09_4
LPS40 Series
 of 3

Related parts for LPS48

LPS48 Summary of contents

Page 1

LPS40 Series 40 Watts Total Power Watts Input Voltage 264 VAC 120 - 300 VDC # of Outputs: Single Special Features • Universal input • 3” x 5” footprint • Less than 1U high • Remote sense • Terminal block option (-T) • Built-in EMI filter • Low output ripple • Adjustable output • Overvoltage protection • Overload protection • ...

Page 2

... Load LPS41(-T) 3 LPS42(- LPS43(- LPS44(- LPS45(- LPS48(- Peak current lasting < 30 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. (-T) indicates Terminal Block option for input and output (instead of Molex type) Power Derating Curve 55W 30 CFM Forced Air Cooling 40W 30W Output Natural Power Convection ...

Page 3

... Warranty: 2 year 7. Weight: 0.5 lbs/0.23kg 5.00" (127) Remote Sense M2 Connector SK201 _ + Voltage Adj. Pot 0.15" (4) DIA (4 places) LPS44 LPS45 LPS48 Line Line Line Neutral Neutral Neutral +15V +24V +48V +15V +24V +48V +15V +24V +48V Common Common Common Common Common Common Common ...

Related keywords