LPT46 Astec Power, LPT46 Datasheet

no-image

LPT46

Manufacturer Part Number
LPT46
Description
AC/DC Power Supply Triple-OUT 5V/24V/12V 5A/1.5A/0.7A 55W 10-Pin
Manufacturer
Astec Power
Type
Switchingr
Datasheet

Specifications of LPT46

Input Voltage
85 to 264 V
Output Voltage
5|24|12 V
Maximum Current Rating
1(rms) A
Maximum Output Current
5|1.5|0.7 A
Number Of Outputs
3
Maximum Output Power
55 W
Efficiency
70(Typ) %
Input Frequency
47 to 440 Hz
Operating Temperature
0 to 50 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPT46
Manufacturer:
ASTEC
Quantity:
1 000
Special Features
• Universal input
• 3” x 5” footprint
• Less than 1U high
• Remote sense on main output
• Terminal Block option (-T)
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety
LPT40 Series
40 Watts
Total Power:
Input Voltage:
# of Outputs:
UL
CSA CSA 22.2-234 Level 3
NEMKO EN 60950/EMKO-TUE
CB
CE
UL60950
E132002
LR53982C
P95100411
(74-sec) 203
1118, 1122, 1123, 1124
Mark (LVD)
Certificate and report
40 - 55 Watts
85 - 264 VAC
120 - 300VDC
Triple
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI:
Safety ground
leakage current:
Output
Maximum Power:
Cross regulation:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection:
Remote sense:
8 5-264 VAC
120-300 VDC
47-440 Hz
< 18 A peak @ 115 VAC;
< 36A peak @ 230 VAC, cold start @ 25 °C
1A max. (RMS) @ 115 VAC
70% typical at full load (60% for LPT41)
F CC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
< 0.5 mA @ 50/60 Hz, 264 VAC input
40W for convection (LPT41, 25W);
55W with 30CFM forced air (LPT41, 41W)
± 2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
S hort circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_164
LPT40 Series
1 of 3

Related parts for LPT46

LPT46 Summary of contents

Page 1

LPT40 Series 40 Watts Total Power Watts Input Voltage 264 VAC 120 - 300VDC # of Outputs: Triple Special Features • Universal input • 3” x 5” footprint • Less than 1U high • Remote sense on main output • Terminal Block option (-T) • Built-in EMI filter • Low output ripple • Adjustable main output • Overvoltage protection • Overload protection • ...

Page 2

... LPT44(-T) +5V 0.4A +12V 0.2A -5V 0A LPT45(-T) +5V 0.4A +15V 0.2A -15V 0A LPT46(-T) +5V 0.4A +24V 0.1A +12V 0A LPT47(-T) +5V 0.4A +24V 0.2A -12V 0A 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. ...

Page 3

... Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5lbs/0.23kg Remote Sense M2 Connector SK201 _ + Voltage Adj. Pot 0.15" (4) DIA (4 places) LPT44 LPT45 LPT46 LPT47 Line Line Line Line Neutral Neutral Neutral Neutral +12V +15V +24V +24V +5V +5V +5V +5V +5V +5V +5V +5V -5V ...

Related keywords