NLP250N-99S24J ARTESYN, NLP250N-99S24J Datasheet

no-image

NLP250N-99S24J

Manufacturer Part Number
NLP250N-99S24J
Description
AC/DC Power Supply Single-OUT 24V 7.3A 250W 18-Pin
Manufacturer
ARTESYN
Datasheet

Specifications of NLP250N-99S24J

Input Voltage
85 to 264 V
Output Voltage
24 V
Maximum Current Rating
2.78(rms) A
Maximum Output Current
7.3 A
Number Of Outputs
1
Maximum Output Power
250 W
Efficiency
86(Typ) %
Input Frequency
47 to 63 Hz
Operating Temperature
0 to 70 °C
Special Features
• Medical safeties
• Active PFC and
• 250 W on main channel with
• Low profile fits 1U applications
• U-Channel for maximum
• Optional cover (CJ suffix)
• 5 V standby output
• 12 V fan output
• Integrated control and
• Overcurrent, overvoltage and
• Compliance to EN55022-B
• Dual AC fuses
• RoHS compliant
• 2 year warranty
Safety
NLP250 Medical
Series
Single Output
Total Power:
Input Voltage: 85 - 264 VAC
# of Outputs:
EN61000-3-2 compliant
forced air
thermal performance
monitoring features
overtemperature protection
conducted noise standard
VDE0750/EN60950
IEC950/IEC60601-1
File No. 1177400-3336-0759
UL60601-1
File No. E186249
Certificate No. 40014041
CB Ref DE1-36628
250 W
Single
Electrical Specifications
Input
Input voltage range:
Input frequency range:
Input surge current:
Safety ground leakage current:
Input current:
Input fuse:
Output
Adjustment range:
Total regulation:
(line and load)
Turn-on delay:
Temperature coefficient:
Overvoltage protection:
Short circuit protection:
Minimum output current:
Maximum power:
Transient response:
Auxiliary outputs:
(See Note 8, page 3)
All specifications are typical at nominal input, full load at 25
Universal input
264 Vac (cold start)
264 Vac, 50 Hz
120 Vac @ 250 W
230 Vac @ 250 W
UL/IEC127
200 LFM forced air
250 LFM with cover
Main output
Main output
Auxiliary outputs
@ 120 Vac Input
Main output
50 - 100%
Step at 0.5 A/µs
Main output
Cyclic operation
Singles
5 Vsb
12 V (fan)
°
C unless otherwise stated
Embedded Power for
Business-Critical Continuity
85 - 264 Vac
47 - 63 Hz
40 A max.
150 µA
2.78 A rms
1.36 A rms
T6.4 AH, 250 Vac In live and
neutral
250 watts
± 5%
± 2.0%
± 5.0%
2.0 s max.
5.0% or 250 mV
max. dev., 1 ms max
recovery to 1%
±0.02%/°C
115%, ± 5%
Continuous
0 A
5 V @ 1.0 A
12 V @ 0.3A
NLP250 Medical Series
Rev.10.1.09_181
1 of 4

Related parts for NLP250N-99S24J

NLP250N-99S24J Summary of contents

Page 1

NLP250 Medical Series Single Output Total Power: 250 W Input Voltage 264 VAC # of Outputs: Single Special Features • Medical safeties • Active PFC and EN61000-3-2 compliant • 250 W on main channel with forced air • Low profile fits 1U applications • U-Channel for maximum thermal performance • Optional cover (CJ suffix) • standby output • fan output • Integrated control and ...

Page 2

EMC Characteristics (5) Conducted emissions: Harmonic current correction: Voltage flicker: ESD air: ESD contact: Radiated immunity: Fast transients: Surge: Conducted immunity: Voltage dips: General Specifications Hold-up time: Efficiency: Isolation voltage: Safety approvals (see Note 6, page 3): Weight: MTBF (@25º C): Environmental Specifications Thermal performance: Relative humidity: Altitude: Vibration (See Note 7, page 3): Shock: EN55022, FCC part 15 Level B EN61000-3-2 Compliant EN61000-3-3 Compliant EN61000-4-2 Level 3 EN61000-4-2 Level 3 EN61000-4-3 Level 3 EN61000-4-4 Level 3 EN61000-4-5 ...

Page 3

... JP1 1 VR7 0.25 (6.35) Embedded Power for Business-Critical Continuity Model Numbers (9, 10) ± 2.0% NLP250N-99S12J ± 2.0% NLP250N-99S24J CUSTOMER MOUNTING HOLES MAX. SCREW PENETRATION 0.08IN 6-32 M3.0 5.850 (148.59) 6.250 (158.75) M3.0 4 PLACES 6-32 4 PLACES 4.700 (119.38) 5.500 (139.70) BOTTOM VIEW Rev.10.1.09_181 ...

Page 4

Figure 1: Derating Curve Output Power (Watts) DERATING CURVE Output Power (Watts) 250 W 200 LFM (1.0 m/s) FORCED AIR COOLING 175 W NATURAL FREE AIR CONVECTION COOLING ...

Related keywords