NLP250R-96S12J ARTESYN, NLP250R-96S12J Datasheet

no-image

NLP250R-96S12J

Manufacturer Part Number
NLP250R-96S12J
Description
AC/DC Power Supply Single-OUT 12V 14.6A 175W 18-Pin
Manufacturer
ARTESYN
Datasheet

Specifications of NLP250R-96S12J

Input Voltage
85 to 264 V
Output Voltage
12 V
Maximum Current Rating
2.78(rms) A
Maximum Output Current
14.6 A
Number Of Outputs
1
Maximum Output Power
175 W
Efficiency
86(Typ) %
Input Frequency
47 to 63 Hz
Operating Temperature
0 to 70 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NLP250R-96S12J
Manufacturer:
VICOR
Quantity:
1 000
Special Features
• Active PFC and EN61000-3-2
• 250 W on main channel with
• Low profile fits 1U applications
• U-Channel for maximum thermal
• Optional cover (CJ suffix)
• 5 V standby output
• 12 V fan output
• Integrated ORing diode
• Active current sharing
• Integrated control and
• Overcurrent, overvoltage and
• Compliance to EN55022-B
• RoHS compliant
• 2 year warranty
• VDE0805/EN60950-1
• UL/cUL 60950-1
• Certificate No. 40014041
• CB Ref DE1-32468
Safety
NLP250 Series
Single Output
Total Power:
Input Voltage: 85 - 264 Vac
# of Outputs:
IEC950/IEC60950-1
File No. 1177400-3336-0759
CSA-C22.2 60950-1
File No. E186249
compliant
forced air
performance
monitoring features
overtemperature protection
conducted noise standard
250 W
Single
Electrical Specifications
Input
Input voltage range:
Input frequency range:
Input surge current:
Safety ground leakage current:
Input current:
Input fuse:
Output
Adjustment range:
Total regulation:
(line and load)
Turn-on delay:
Temperature coefficient:
Overvoltage protection:
Short circuit protection:
Minimum output current:
Maximum power:
Transient response:
Auxiliary outputs:
(See Note 8)
All specifications are typical at nominal input, full load at 25
Universal input
264 Vac (cold start)
264 Vac, 50 Hz
120 Vac @ 250 W
230 Vac @ 250 W
UL/IEC127
200 LFM forced air
250 LFM with cover
Main output
Main output
Auxiliary outputs
@ 120 Vac Input
Main output
50 - 100%
Step at 0.5 A/µs
Main output
Cyclic operation
Singles
5 Vsb
12 V (fan)
°
C unless otherwise stated
Embedded Power for
Business-Critical Continuity
85 - 264 Vac
47 - 63 Hz
40 A max.
1 mA
2.78 A rms
1.36 A rms
T6.3 AH, 250 Vac
250 watts
± 5%
± 2.0%
± 5.0%
2.0 s max.
5.0% or 250 mV
max. dev., 1 ms max
recovery to 1%
±0.02%/°C
115%, ± 5%
Continuous
0 A
5 V @ 1.0 A
12 V @ 0.3A
Rev.04.01.10_1
NLP250 Series
1 of 4

Related parts for NLP250R-96S12J

NLP250R-96S12J Summary of contents

Page 1

NLP250 Series Single Output Total Power: 250 W Input Voltage 264 Vac # of Outputs: Single Special Features • Active PFC and EN61000-3-2 compliant • 250 W on main channel with forced air • Low profile fits 1U ...

Page 2

EMC Characteristics (5) Conducted emissions: Harmonic current correction: Voltage flicker: ESD air: ESD contact: Radiated immunity: Fast transients: Surge: Conducted immunity: General Specifications Hold-up time: Efficiency: Isolation voltage: Safety approvals (see note 6): Weight: MTBF (@25 ºC): Environmental Specifications Thermal ...

Page 3

... J3 JP1 1 VR7 0.25 (6.35) Embedded Power for Business-Critical Continuity Model Numbers (9, 10) ± 2.0% NLP250R-96S12J ± 2.0% NLP250R-96S24J ± 2.0% NLP250R-96S48J CUSTOMER MOUNTING HOLES MAX. SCREW PENETRATION 0.08IN 6-32 M3.0 5.850 (148.59) 6.250 (158.75) M3.0 4 PLACES 6-32 4 PLACES 4.700 (119.38) 5 ...

Page 4

Derating Curve Output Power (Watts) DERATING CURVE Output Power (Watts) 250 W 200 LFM (1.0 m/s) FORCED AIR COOLING 175 W NATURAL FREE AIR CONVECTION COOLING ...

Related keywords