D6F20A6000 Omron, D6F20A6000 Datasheet
D6F20A6000
Specifications of D6F20A6000
Related parts for D6F20A6000
D6F20A6000 Summary of contents
Page 1
... Aluminum alloy Cable Connector Assembly - - - Note: Cable Assembly is sold separately. * Contact Omron for other gases or thread types. **Mass flow converted to volumetric flow (standard liters per minute) at 0°C and 1 atm. ■ Application Examples • Industrial processes • Medical Respirators and Ventilators • ...
Page 2
... VDC, between lead terminal and case Dielectric Strength 500 VAC, 50/60 Hz, for 1 minute. (Leakage current typ <1 mA.), between the lead terminals and the base Response Time (reference) 150 mS, typical * Contact Omron for other thread types (A6) ** Contact Omron for other gases. Operating Characteristics D6F-10A 6.0 5 ...
Page 3
... Material: NBR70 (recommended for all applications including medical and food processing.) • Example part number: JASO part number: CO 0003 • Alternative manufacturers with similar DO and W dimensions may be used O ring 1.9 ± 0.07 Inlet MEMS Airflow Sensor Outlet D6F-10A, -20A, -50A 25 ...
Page 4
... Note: Be sure to read the precautions and information common to all D6F sensors, contained in the Technical User’s Guide, “D6F Technical Information” for correct use. D6F-10A, -20A, -50A 26 MEMS Airflow Sensor 14±0.1 3.4 30.4 Two, 5-dia holes 12±0.2 3.4 30 ...
Page 5
... D6F-10A, -20A, -50A MEMS Airflow Sensor MEMO ...
Page 6
... All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B ...