CG37.5LTR

Manufacturer Part NumberCG37.5LTR
ManufacturerLittelfuse Inc
CG37.5LTR datasheet
 


Specifications of CG37.5LTR

Surge Current Max10KAFailsafe ProtectionNo
Mounting StyleThrough HoleOperating Temp Range-40C to 125C
Lead Free Status / RoHS StatusCompliant  
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (293Kb)Embed
Next
DEVICES
SRC
SRC Devices 2 electrode high voltage CG3 Comgaps (1.0 - 8.5 kV) are designed for surge protection in applications for which
bias voltages or signal levels of several hundred volts are normally present. Comgaps function as switches which dissipate
a minimum amount of energy and therefore handle currents that far surpass other types of transient voltage protection.
FEATURES
Rugged ceramic-metal construction
Non-radioactive
Low capacitance (<1pF)
Available in tape-and-reel packaging
Available with or without leads
APPROVALS
UL Recognized: File Number E111526
CSA Approved: File Number LR89617
www.srcdevices.com
TWO ELECTRODE HIGH VOLTAGE SURGE ARRESTERS
2 ELECTRODE HIGH VOLTAGE SURGE ARRESTERS
DESCRIPTION
Parameter
DC Breakdown Voltage
Insulation Resistance
Capacitance
Operational Temperature
(See detailed specifications for more information.)
USA
1-866-SRC-8668
Europe
32-89-328850
Far East
CG3 Series
APPLICATIONS
CRT terminal
CATV equipment
Antennas
Power supplies
Medical electronics
o
RATINGS (@ 25
C)
Min
Typ
Max
800
1000
1200
1200
1500
1800
1600
2000
2400
2000
2500
3000
2400
3000
3600
3200
4000
4800
4000
5000
6000
6000
7500
9000
6800
8500
10200
10
10
-
-
-
-40
-
+125
886-2-2698-8422
Unit
V
V
V
V
V
V
V
V
V
-
1
pF
°C
8

CG37.5LTR Summary of contents

  • Page 1

    DEVICES SRC SRC Devices 2 electrode high voltage CG3 Comgaps (1.0 - 8.5 kV) are designed for surge protection in applications for which bias voltages or signal levels of several hundred volts are normally present. Comgaps function as switches which ...

  • Page 2

    TWO ELECTRODE HIGH VOLTAGE SURGE ARRESTERS CG3 Series o All characteristics PARAMETER Device Specifications DC Breakdown Impulse Breakdown Insulation Resistance Capacitance Arc Voltage Mechanical Outline Life Ratings (1) Surge Life Max Current Surge AC Follow-on Current PARAMETER ...

  • Page 3

    DEVICES SRC All characteristics at 25°C PARAMETER Device Specifications DC Breakdown Impulse Breakdown Insulation Resistance Capacitance Arc Voltage Mechanical Outline (1) Life Ratings Surge Life Max Current Surge AC Follow-on Current (1) End-of-life limits are: DC: 50% of minimum initial ...