8-1611476-0 TE Connectivity, 8-1611476-0 Datasheet

no-image

8-1611476-0

Manufacturer Part Number
8-1611476-0
Description
4000-04C02K999=TRANSFORMER
Manufacturer
TE Connectivity
Datasheet

Specifications of 8-1611476-0

Lead Free Status / RoHS Status
Compliant
Specifications and/or agency recognitions do not necessarily apply to all models within a particular series. When multiple ratings are listed, no individual rating may be exceeded by the combination of others.
Dimensions are shown for
reference purposes only.
Series
Type
VA Rating
Terminal Options
Mounting Options
Agency Approval
Page Number
Series
Type
VA Rating
Terminal Options
Mounting Options
Agency Approval
Page Number
Click here for Alphanumeric Index
Non-Inherently Energy Limited
(Opt. integral fuse or breaker)
Secondary Fusing Required
5, 10, 20 & 30VA
PRODUCTS
UNLIMITED
Class II UL1585
Class II UL1585
Energy Limited
PRODUCTS
UNLIMITED
Foot or Panel
Foot or Panel
Transformer
Transformer
Wire Leads
Wire Leads
4000
60 & 75VA
4000
Inherently
204
209
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Non-Inherently Energy Limited
(Opt. integral fuse or breaker)
Secondary Fusing Required
PRODUCTS
UNLIMITED
Class II UL1585
Energy Limited
PRODUCTS
UNLIMITED
Class II UL1585
10, 20 & 30VA
Quick Connect
Quick Connect
Foot or Panel
Foot or Panel
Transformer
Transformer
4000
60 & 75VA
Inherently
4000
205
210
Transformers
Transformers
Catalog 1308242
Issued 3-03
Wire Leads & Screws
60, 100 & 150VA
PRODUCTS
UNLIMITED
Class II UL1585
Energy Limited
PRODUCTS
UNLIMITED
Transformer
Transformer
20 & 40VA
Wire Leads
4000
Non-Fused
Inherently
4700
UL506
Plate
206
Foot
211
Specifications and availability
subject to change.
60, 100 & 150VA
PRODUCTS
Class II UL1585
UNLIMITED
PRODUCTS
Energy Limited
UNLIMITED
Quick Connect
Foot or Panel
Transformer
Transformer
WIre Leads
40 & 50VA
4000
Non-Fused
Inherently
4700
UL506
207
Foot
211
(optional Quick Connects)
SELECTOR GUIDE
Wire Leads and Screws
9100 or 9400 Series
PRODUCTS
UNLIMITED
Class II UL1585
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Energy Limited
PRODUCTS
UNLIMITED
Quick Connect
Energy Limited
Foot or Panel
Transformer
Transformer
40 & 50VA
4000
Inherently
Inherently
57
208
Relay
Relay
40VA
Plate
212
vii

Related parts for 8-1611476-0

8-1611476-0 Summary of contents

Page 1

... Wire Leads & Screws Foot or Panel Plate 205 206 Transformers PRODUCTS PRODUCTS UNLIMITED UNLIMITED 4000 4700 Class II UL1585 UL506 Transformer Transformer Non-Inherently Energy Limited Non-Fused Secondary Fusing Required (Opt. integral fuse or breaker) 60 & 75VA 60, 100 & 150VA Quick Connect Wire Leads ...

Page 2

... Wire Leads, Class II ................. 207 4000 ................... 40-50VA, QC Terminals, Class II ............. 208 4000 ................... 60-75VA, Wire Leads, Class II ................. 209 4000 ................... 60-75VA, QC Terminals, Class II ............. 210 4700 ................... 60-150VA, Wire Leads or QC, UL 508 .... 211 57 ....................... Transformer Relay for HVAC ................... 212 Transformers........ Custom Capabilities........................................203 Transformers........ Questions and Answers..................................202 ...

Page 3

... Typical USA supply voltages are 120, 208, 240, 277, 480 (and 575 in Canada). Common International voltages include 110, 220, 380, and 415. What is an Isolation Transformer? An isolation transformer is a transformer whose primary and secondary windings are separate for the purpose of isolating the circuit from the supply source ...

Page 4

... Our electrical and mechanical design groups are ready to work with you on your specific product needs. Dimensions are shown for Dimensions are in inches over reference purposes only. (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 DFM Method • DPPM level <100 • 1 Week lead time • 1 Universal part number • ...

Page 5

... All leads are 18 AWG stranded 2/64” (.794 mm) insulation thickness. Standard parts have 12” (305 mm) total length with 1/2” (12.7 mm) strip. 50/60 Hz. UL Class B (130°C). 5VA – 10.56 oz. (300 g); 10VA – 10.88 oz. (308 g); 20VA – 14.24 oz. (404 g); 30VA – 19.2 oz. (544 g). 5VA 10VA 20VA ...

Page 6

... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 10VA – 10.9 oz. (308 g); 20VA – 14.1 oz. (399 g); 30VA – 18.6 oz. (525 g). Primary V Secondary V 10VA ...

Page 7

... PRODUCTS UNLIMITED series File E87824 All leads are 18 AWG stranded 2/64” (.794 mm) insulation thickness. Standard parts have 12” (305 mm) total length with 1/2” (12.7 mm) strip. 50/60 Hz. UL Class B (130°C). 20VA – 19.2 oz. (544 g); 40VA – 32 oz. (906 g). ...

Page 8

... It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. All leads are 18 AWG stranded 2/64” (.794 mm) insulation thickness. Standard parts have 12” (305 mm) total length with 1/2” (12.7 mm) strip. ...

Page 9

... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 40VA – 22.4 oz. (636 g); 50VA – 35.2 oz. (999 g). ...

Page 10

... Type K Foot Mount - features a steel bracket welded to the bottom of the laminations for easy mounting. • Type G Panel Mount - features .218” (5.54 mm) diameter holes in each corner to allow direct mounting to a panel. • For agency approval, 60 & 75VA transformers must have one of the following overcurrent protectors in series with the secondary winding: Internal fuse, integral circuit breaker ...

Page 11

... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 60VA – 35.2 oz. (997 g); 75VA – 38.4 oz. (1087 g). ...

Page 12

... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 60VA – 36.8 oz. (1042 g); 100VA – 80 oz. (2270 g); 150VA – 83.2 oz. (2356 g). Primary V 100VA 120 – ...

Page 13

... Cover mounts on conventional 4” square box. • All leads terminate in the box. • Leads are 8” (203.2 mm) long with 1/2” (12.7mm ) stripped) • Standard transformer is 40VA Class II Energy Limited. Other transformers are available. • Five secondary terminations (two are hot) for thermostat connection and #6-32 screw termination is standard. Quick connects are optional. • ...

Related keywords