DC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A

CPA200-4530G

Manufacturer Part NumberCPA200-4530G
DescriptionDC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A
ManufacturerPOWER ONE
CPA200-4530G datasheet
 


Specifications of CPA200-4530G

Input Voltage90 to 264VNumber Of Outputs4
Input Frequency47 to 63HzEfficiency83%
Screening LevelCommercialProduct Height (mm)40.6mm
Operating Temperature Min Deg. C-25COperating Temperature Max Deg. C50C
Mounting StyleDesktopOutput Power200 W
Input Voltage Range90 V to 264 VInput Voltage (nominal)230 V
Output Voltage (channel 1)5 VOutput Current (channel 1)20 A
Output Voltage (channel 2)3.3 VOutput Current (channel 2)20 A
Output Voltage (channel 3)12 VOutput Current (channel 3)2.5 A
Package / Case Size233.3 mm x 162.5 mm x 40.4 mmOutput Voltage5 V to 12 V
Lead Free Status / RoHS StatusCompliant  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
12
13
14
15
16
17
18
19
Page 1/19

Download datasheet (548Kb)Embed
Next
200 – 550 Watt CompactPCI
®
Description
The CPA and CPD Series are highly reliable power supplies
®
for CompactPCI
systems, which are increasingly used in
communications, industrial, military, aerospace, and other
applications. These power supplies offer high power density
in plug-in modules that meet the requirements of the
®
PICMG
power interface specification for CompactPCI
systems.
The converters use the patented EDGE
provide important advantages such as flexible output
power, extremely high efficiency, excellent reliability, full
input-to-output isolation, negligible inrush current, hot-swap
capability, soft start, and overtemperature protection.
The input is protected by a transient suppressor (varistor)
against surges and transients occurring on the source lines
and cover an operating input voltage range from either 90 to
264 VAC or 36 to 75 VDC.
The outputs are protected against continuous overload,
open-circuit, and short-circuit. Full n+1 redundant operating
mode is made possible by integrated ORing FETs or ORing
Table of Contents
Description ....................................................................... 1
Model Selection ............................................................... 2
Functional Description ..................................................... 3
Electrical Input Data ......................................................... 5
Electrical Output Data ...................................................... 7
Auxiliary Functions ......................................................... 10
BCD20005-G Rev. AF, 18-Aug-10
®
233.3
7.8"
6 U
Features
• RoHS lead-free-solder and lead-solder-exempted
162.5
products are available
40.4
6.4"
1.6"
8 HP
• Compliant with PICMG
• Wide range DC or AC input with PFC
• Extremely high efficiency and high power density
• Low inrush current
• 4 high current outputs with flexible load distribution
• Integrated ORing FETs / diodes for true redundancy
• Inhibit and enable inputs
®
• Remote sense lines
• Single-wire current share function for 3 outputs
TM
technology and
• Hot-swap capability
• 47-pin connector, type Positronic
• Overtemperature, overvoltage, overcurrent, and
overpower protection
Safety according to IEC/EN 60950-1 2
UL/CSA 60950-1 2
Page
Electromagnetic Compatibility (EMC) ............................ 13
Immunity to Environmental Conditions .......................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Options ........................................................................... 19
Page 1 of 19
CPA, CPD Series Data Sheet
AC-DC and DC-DC Converters
162.5
40.6
6.4"
1.6"
8 HP
®
®
CompactPCI
specifications
nd
Ed. and
nd
Ed.
www.power-one.com
100
3.94"
3 U
Page

CPA200-4530G Summary of contents

  • Page 1

    Watt CompactPCI ® Description The CPA and CPD Series are highly reliable power supplies ® for CompactPCI systems, which are increasingly used in communications, industrial, military, aerospace, and other applications. These power supplies offer high power density ...

  • Page 2

    ... Vo3 12 Vo4 –12 CPD250-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPD500-4530G Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA200-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA250-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA500-4530 Vo1 5.0 Vo2 3.3 ...

  • Page 3

    Watt CompactPCI ® Product Marking Label with specific type designation, applicable safety approvals and recognition marks, CE mark, warnings, Power-One patents, company logo, input voltage range, Functional Description The inputs of all converters are protected against surges ...

  • Page 4

    Watt CompactPCI ® technique and proprietary leading and trailing-edge pulse- width modulation. It has a proven track record in high- availability power solutions. The switching frequency is typically 135 kHz. Some models (CPx200/250 version V117, CPA500/550 version ...

  • Page 5

    ... First value for CPD/CPA200, 2 value for CPD/CPA250 3 nd First value for CPA500, 2 value for CPA550 4 Short interruption of V without affecting the outputs i 5 CPA200/250 with version V117 or higher, as they are equipped with an input voltage trigger BCD20005-G Rev. AF, 18-Aug-10 CPD200/250 Conditions min typ – max T – ...

  • Page 6

    ... CPD500 models start and switch off CPA models exhibit an undervoltage trigger controlling start-up and shutdown. The threshold is between 80 and 90 VAC. See also Power Fail Signal. Note: CPA200/250 with version operated these models have no undervoltage i i min shutdown and will therefore operate with a high input current at full load ...

  • Page 7

    ... Electrical Output Data General Conditions for table 4: – °C, unless T is specified – CPD/CPA200: 250 LFM (1.25 m/s), CPD/CPA250: 400 LFM (2 m/s) – Sense lines connected directly at the connector Table 4a: Output data of CPD/CPA200 and CPD/CPA250 Output Characteristics Conditions V Output voltage ...

  • Page 8

    Watt CompactPCI ® General conditions for table 5: – °C, unless T is specified – CPD500, CPA500: 300 LFM (1.5 m/s), CPA550: 400 LFM (2 m/s) – Sense lines connected directly at ...

  • Page 9

    ... The thermal conditions are significantly influenced by the input voltage, the output current, the airflow, and the temperature of the adjacent elements and surfaces. T value only 1.0 0.6 0.5 0 Fig. 4a Output power versus temperature T CPA200 1 05186b o max Fig. 4b Output power versus temperature T ...

  • Page 10

    Watt CompactPCI ® nom 300 LFM = 1.5 m/s (CPA/CPD500) 400 LFM = 2 m/s (CPA550) JM012a 1.0 Convection cooling in upright position CPA/CPD500 0.6 0.5 CPA550 min ...

  • Page 11

    ... nom BCD20005-G Rev. AF, 18-Aug-10 The threshold levels for V CPD models and 80 – 90 VAC for CPA models. Note: CPD200/250 (and CPA200/250 up to version V116) changes from high DEG# provide only the signal FAL#, but the converter is not inhibited. falls C Note remains for typ ...

  • Page 12

    Watt CompactPCI ® Active Current Sharing for Vo1, Vo2, Vo3 The current share facility, consisting of a single-wire link, should be used, where several converters are operated in parallel connection, for example, high reliability n+1 redundant systems ...

  • Page 13

    Watt CompactPCI ® Electromagnetic Compatibility (EMC) A metal oxide VDR together with the input fuse and a filter form an effective protection against high input voltage Electromagnetic Immunity Table 8: Immunity type tests Phenomenon Standard Level Electrostatic ...

  • Page 14

    Watt CompactPCI ® Electromagnetic Emission Radiated and conducted emissions comply with EN 55011/ 55022, class A. In addition, CPD500 and CPA500/550 meet conducted emissions class B. dBµV CPD200, B738613, 50807-TU, Peak L, Conducted 0. MHz, ...

  • Page 15

    ... Shock IEC/EN 60068-2-27 (half-sinusoidal) Eb Bump IEC/EN 60068-2-29 (half-sinusoidal) Fda Random vibration IEC/EN 60068-2-35 wide band, CPD200/250, CPA200/250 reproducibility high IEC/EN 60068-2-35 CPD500, CPA500/550 Drop test Converter in proper packing CPD200/250 1 Version V106 or higher Temperatures Table 10: Temperature specifications, valid for an air pressure of 800 – 1200 hPa (800 – 1200 mbar) ...

  • Page 16

    ... Watt CompactPCI ® Mechanical Data Dimensions in mm (inches) Fig. 15 CPA200/250 and CPD200/250. Overall size: 162.5 x 128.7 x 40.6 mm. Weight: 0.8 kg (0.098") Fig. 16 View of the connector Fig. 17 CPD500 and CPA500/550. Overall size: 223.4 x 162.5 x 40.6 mm. Weight: 1.65 kg (0.098") BCD20005-G Rev. AF, 18-Aug-10 ...

  • Page 17

    Watt CompactPCI ® Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the Positronic connector. Pin no. 45 (protective earth leading pin, ...

  • Page 18

    Watt CompactPCI ® Table 13: Isolation Characteristic Electric Actual factory test 1 s strength AC test voltage equivalent test to factory test Insulation resistance at 500 VDC 1 According to IEC/EN 60950, subassemblies connecting input to output ...

  • Page 19

    Watt CompactPCI ® Options L: Output Current Latch All CPA/CPD models exhibit a latching shutdown, which is activated if only one output voltage is too high; see Output Characteristic and Protection. If option L is fitted, this ...