DC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A

CPA200-4530G

Manufacturer Part Number
CPA200-4530G
Description
DC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A
Manufacturer
POWER ONE
Datasheet

Specifications of CPA200-4530G

Input Voltage
90 to 264V
Number Of Outputs
4
Input Frequency
47 to 63Hz
Efficiency
83%
Screening Level
Commercial
Product Height (mm)
40.6mm
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Output Power
200 W
Input Voltage Range
90 V to 264 V
Input Voltage (nominal)
230 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
20 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
2.5 A
Package / Case Size
233.3 mm x 162.5 mm x 40.4 mm
Output Voltage
5 V to 12 V
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
Active Current Sharing for Vo1, Vo2, Vo3
The current share facility, consisting of a single-wire link,
should be used, where several converters are operated in
parallel connection, for example, high reliability n+1
redundant systems or systems providing higher output
power.
Using this feature reduces the stress of the individual
converters and improves the reliablity of the system.
Interconnection of the current sharing terminals causes the
converters to share the output current evenly. In n+1
redundant systems a failure of a single converter will not
lead to a system failure, since the outputs are already
decoupled by FETs and diodes internally.
Passive Current Sharing for Vo4
The output voltage changes slightly with the output current
(droop characteristic) ensuring automatic current sharing
without further precautions, when several converters are
Fig. 12
Display status of LEDs
BCD20005-G Rev. AF, 18-Aug-10
Input OK
Note: Maximum six converters should be connected in
parallel.
Fault
Fault
Fault
Fault
-2 V
LED off
If +12 V bus voltage is present, LED is on.
V
i min
®
+0.8 V
LED Status undefined
200 – 550 Watt CompactPCI
+2.4 V
V
inh threshold
T
C max
I
V
oL
i max
+50 V
Page 12 of 19
06156a
LED on
V
T
V
I
O
i inh
C
i
V
connected in parallel. An increase in output current
decreases the output voltage according to fig. 11.
Fig. 11
Output voltage V
LEDs
A green LED "Input OK" and a red LED "Fault" are
incorporated in the front panel.
–4%
+2%
–4%
–2%
o4 set
LEDs "Input OK" and "Fault" status versus input voltage.
Conditions: P
LED "Fault" status versus output current.
Conditions: V
LED "Fault" status versus case temperature.
Conditions: P
LED "Fault" status versus V
Conditions: P
V
o
0.01
CPx500/550
®
AC-DC and DC-DC Converters
CPA, CPD Series Data Sheet
o
i min
o
o
– P
– P
– P
o 4
– V
versus output current I
o max
o max
o max
i max,
, T
, V
, V
0.5
C
T
i min
i min
CPx200/250
C
– T
inh
– T
– V
– V
.
C max
C max
i max
i max
, V
, V
, V
, T
inh
C
www.power-one.com
inh
inh
o 4
= open
– T
= open
= open
.
C max
1
I
o
/I
o nom

Related parts for CPA200-4530G