CPA200-4530G POWER ONE, CPA200-4530G Datasheet - Page 17

DC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A

CPA200-4530G

Manufacturer Part Number
CPA200-4530G
Description
DC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A
Manufacturer
POWER ONE
Datasheet

Specifications of CPA200-4530G

Input Voltage
90 to 264V
Number Of Outputs
4
Input Frequency
47 to 63Hz
Efficiency
83%
Screening Level
Commercial
Product Height (mm)
40.6mm
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Output Power
200 W
Input Voltage Range
90 V to 264 V
Input Voltage (nominal)
230 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
20 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
2.5 A
Package / Case Size
233.3 mm x 162.5 mm x 40.4 mm
Output Voltage
5 V to 12 V
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
Safety and Installation Instructions
Connector Pin Allocation
The connector pin allocation table defines the electrical
potentials and the physical pin positions on the Positronic
connector. Pin no. 45 (protective earth) is a leading pin,
ensuring that it makes contact with the female connector
first.
Installation Instructions
These converters are components, intended exclusively for
installation within other equipment by an industrial
assembly process or by a professionally, competent
person. Installation must strictly follow the national safety
regulations in respect of the enclosure, mounting, creepage
distances, clearance, casualty markings, and segregation
requirements of the end-use application.
Connection to the system shall be made via the mating
female connector (see fig. 16). Other installation methods
Fig. 18
Pinout of the front connector
Table 12: Pin allocation of the front connector
13 – 18
BCD20005-G Rev. AF, 18-Aug-10
Mating female connector: Positronic PCIH47F300A1 or similar
5 – 12
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20
1 – 4
Pin
1
2
3
4
5
19
20
21
22
23
24
25
26
27
28
29
30
31
Pin numbers shown are for the female backplane connector
A = very long pins, B = long pins, C = short pins, D = very short pins.
Pin 45 of the female connector is leading, ensuring that chassis ground makes contact first.
CPD models (DC input)
CPA models (AC input)
Connector: Positronic PCIH47M400A1 or similar
1
Length
B
B
B
B
B
C
C
C
C
C
C
D
C
C
C
C
2
Signal
name
Vo1
RTN
Vo2
RTN
Vo3
Vo4
RTN
Reserved
RTN
n.c.
Reserved
EN#
n.c.
n.c.
Vo1SENSE
n.c.
®
21 24 27 30 33 36 39 42
22 25 28 31 34 37 40 43
23 26 29 32 35 38 41 44
200 – 550 Watt CompactPCI
Description
Output 1
Return (Vo1 and Vo2)
Output 2
Return (Vo3)
Output 3
Output 4
Return
Reserved
Return (Vo4)
Do not connect
Reserved
Enable
Do not connect
Do not connect
Vo1 remote sense
Do not connect
45
46
10087a
Page 17 of 19
47
may not meet the safety requirements. Check for hazardous
voltage, before altering any connections.
The converters are provided with a leading pin no. 45, which
is reliably connected to the case. For safety reasons it is
essential to connect this pin to the protective earth of the
supply system.
The input –DCIN or ACL (pin no. 47) is internally fused; see
Input Fuse and Protection. This fuse is designed to break an
overcurrent in case of a malfunction of the converter and is
not customer-accessible.
External fuses in the wiring to one or both input lines (pin 47
and/or pin 46) may be necessary to ensure compliance with
local requirements. A built-in second fuse in the neutral line
(pin 47) is available as option F for CPA500 models.
A second fuse in the wiring to the neutral line or option F may
be needed if:
Pin
• Local requirements demand an individual fuse in each
• Neutral and earth impedance is high or undefined
• Phase and neutral of the mains are not defined or cannot
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
Caution:
Installation must strictly follow the national safety regulations.
Models with option F: Caution! Double-pole/neutral fusing.
Do not open the converters, or the warranty will be
invalidated!
Important: If the inhibit function is not used, pin 39 (i) should
be left open-circuit to enable the outputs. Enable Pin 27 (EN#)
should be connected to pin 22 (RTN) to enable the outputs.
source line
be assigned to the corresponding terminals.
1
Length
A
C
C
C
C
C
C
C
C
C
C
C
C
C
A
A
3
®
2
AC-DC and DC-DC Converters
Signal
name
n.c.
Vo2SENSE
SRTN
Vo1SHARE
Vo3SENSE
n.c.
DEG#
INH#
n.c.
Vo2SHARE
FAL#
n.c.
Vo3SHARE
CGND
+DCIN
–DCIN
CPA, CPD Series Data Sheet
4
4
ACN
ACL
5
5
Description
Do not connect
Vo2 remote sense
Sense return
Vo1 current share
Vo3 remote sense
Do not connect
Degrade signal
Inhibit
Do not connect
Vo2 current share
Fail signal
Do not connect
Vo3 current share
Chassis ground
Pos. DC input
Neg. DC input
4
4
www.power-one.com
Line input (phase)
Neutral line
5
5

Related parts for CPA200-4530G