CPA200-4530G POWER ONE, CPA200-4530G Datasheet - Page 8

DC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A

CPA200-4530G

Manufacturer Part Number
CPA200-4530G
Description
DC/DC Converters & Regulators 90-264Vin 200W 5V20A 3.3V20A/12V2.5A
Manufacturer
POWER ONE
Datasheet

Specifications of CPA200-4530G

Input Voltage
90 to 264V
Number Of Outputs
4
Input Frequency
47 to 63Hz
Efficiency
83%
Screening Level
Commercial
Product Height (mm)
40.6mm
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Output Power
200 W
Input Voltage Range
90 V to 264 V
Input Voltage (nominal)
230 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
20 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
2.5 A
Package / Case Size
233.3 mm x 162.5 mm x 40.4 mm
Output Voltage
5 V to 12 V
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
General conditions for table 5:
Table 5 a: Output data of CPD500 and CPA500/550
BCD20005-G Rev. AF, 18-Aug-10
Table 5 b: Output data of CPD500 and CPA500/550
– T
– CPD500, CPA500: 300 LFM (1.5 m/s), CPA550: 400 LFM (2 m/s)
– Sense lines connected directly at the connector
Output
Characteristics
V
I
I
I
I
v
v
t
Output
Characteristics
V
I
I
I
I
v
v
t
o nom
o max
oL
o min
d
o
o d
o nom
o max
oL
o min
V
V
V
d
V
o
o
V
V
V
o d
1
2
3
4
o
V
oV
oL
oS
o
oV
oL
oS
A
o
First value for CPA500, second value for CPA550
Minimum load is only required to maintain regulation of output Vo4. No min. load for CPD500.
Droop characteristic for passive current sharing
Measured with a probe according to IEC/EN 61204, annex A
= 25 °C, unless T
Output voltage
Nominal output current
Max. output current
Output current limit
Minimum load
Output
voltage
noise
Static line regulation
Static load regulation
Overshoot at switch on/off
Dynamic
load
regulation
Temperature coefficient
of output voltage
Output voltage
Nominal output current
Max. output current
Output current limit
Minimum load
Output
voltage
noise
Static line regulation
Static load regulation
Overshoot at switch on/off
Dynamic
load
regulation Recovery time
Temperature coefficient
of output voltage
4
4
Switch. frequ.
Total
Voltage
deviation
Recovery time
Switch. frequ.
Total
Voltage
deviation
®
c
is specified.
200 – 550 Watt CompactPCI
V
T
V
BW = 20 M Hz
C
V
V
Vo1: I
Vo2: I
T
0 – I
Conditions
Conditions
V
V
T
V
BW = 20 MHz
C
V
V
Vo3: I
Vo4: I
T
0 – I
V
C min
C min
i nom
i nom
i min
i nom
C min
C min
i nom
i min
i nom
i min
i nom
ext
ext
i min
o nom
o nom
= 22 F + 100 nF
= 22 µF + 100 nF
– V
, 50% I
, I
, 50 – 100% I
– V
– V
, 50% I
, I
, I
– V
– T
– T
– T
– T
o nom
o1
o2
o nom
o
o3
o4
, V
i max
= 2 – 4 A
, V
i max
i max
C max
i max
C max
C max
C max
= 20 A, dI
= 40 A, dI
= 1 A, dI
= 4 A, dI
i min
i min
o nom
, I
o nom
, I
o nom
o nom
4
4
– V
– V
o3
o4
i max
o max
i max
o1
o2
/dt = 2 A/µs
/dt = 2 A/µs
/dt = 2 A/µs
/dt = 2 A/µs
Page 8 of 19
11.76
min
4.95
52.2
min
no min. load required
I
o3
Vo3 (+12 V)
Vo1 (5.0 V)
> 75% I
40/50
±0.3
12.0
13.5
300
±0.3
typ
300
12
typ
5.0
®
50
8
0
0
AC-DC and DC-DC Converters
1
o 4
CPA, CPD Series Data Sheet
2
12.24
±200
±150
max
max
5.05
120
±10
±50
±10
±10
62
50
–11.52
no min. load required
min
3.25
min
63
no min. load required
Vo4 (–12 V)
Vo2 (3.3 V)
– 220
–12.0
±0.5
300
50/50
typ
4.3
3
4
0
±0.2
300
typ
3.3
60
0
3
1
–12.48
www.power-one.com
±150
max
120
±10
±150
max
±10
±10
3.35
50
74
mV/K
mV
VDC
Unit
mV
mV/K
µs
VDC
mV
A
Unit
mV
µs
A
pp
pp

Related parts for CPA200-4530G