MAP110-4200 POWER ONE, MAP110-4200 Datasheet

Linear & Switching Power Supplies 110W 12V 5A 24V 4A/ -12V 1A

MAP110-4200

Manufacturer Part Number
MAP110-4200
Description
Linear & Switching Power Supplies 110W 12V 5A 24V 4A/ -12V 1A
Manufacturer
POWER ONE
Type
Open Framer
Datasheet

Specifications of MAP110-4200

Input Voltage
85 to 264V
Number Of Outputs
4
Mounting Style
Screw
Output Current (max)
5/4/1/2A
Output Voltage
12/24/-12/-5V
Output Power (max)
80W
Input Frequency
47 to 63Hz
Efficiency
80%
Screening Level
Commercial
Product Length (mm)
177.8mm
Product Height (mm)
50mm
Product Depth (mm)
109.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
19
Product
Switching
Commercial/medical
Commercial
Output Power Rating
240 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
12 A, 20 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
5 A, 9 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
1 A, 1.5 A
Dimensions
7 in L x 4.3 in W x 1.97 in H
Brand/series
MAP110 Series
Configuration
Open-Frame
Current, Input
3.5 A (RMS) @ 85 VAC, 2.8 A (RMS) @ 110 VAC
Current, Leakage
750 μA (Max.)
Hold Time
40 mS (Min.) 50% Load, 20 mS (Min.) Full Load
Mounting Type
Panel
Operation
Switching
Output
-12 VDC @ 1/1.5 A, +5 VDC @ 2/2.5 A, +12 VDC @ 5/9 A, +24 VDC @ 4/4.5 A
Power, Output
80 W
Power, Rating
110 W (Continuous)
Primary Type
AC-DC
Special Features
Remote Sense
Temperature, Operating
50 °C
Voltage, Input
85 to 264 VAC
Voltage, Output
-12, +5, +12, +24 VDC
Voltage, Output 1
-5 V
Voltage, Output 2
-12 V
Voltage, Output 3
12 V
Voltage, Output 4
24 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / RoHS Status
Not Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Not Compliant
Power-One’s MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units
bear the CE Mark.
Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an
international standard footprint. Input and output connections are made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage
requirements.
Single-Output Model Selection
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
MCD10142 Rev. 1.0, 27-Jan-10
Description
Multiple-Output Model Selection
MAP110-1005
MAP110-1012 12V/15V
MAP110-1024 24V/28V
MODEL
MODEL
MAP110-4000
MAP110-4001
MAP110-4002
MAP110-4003
MAP110-4004
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation.
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
5V
+5V
+5V
+5V
+5V
+5V
-5V
-5V
11.25V to 15.75V
4.95V to 5.50V
22.8V to 29.2V
4.75V to 5.25V
4.75V to 5.25V
4.75V to 5.25V
4.75V to 5.25V
4.75V to 5.25V
ADJUSTMENT
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
– 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM)
3.8/3.2A (Note 2)
CONVECTION COOLED
7.5/6A (Note 2)
OUTPUT CURRENT
CONVECTION COOLED
CURRENT (NOTE 1)
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
5A/9A PK
16A
Page 1 of 5
5.0/4.3A (Note 2)
10/8A (Note 2)
OUTPUT CURRENT
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
FORCED AIR
FORCED AIR
5A/9A PK
5A/9A PK
CURRENT
22A
Features
• RoHS lead-solder-exemption compliant
• New 3.3 V and 5 V output models
• Universal input 85-264 VAC
• Industry-standard footprint: 7.00" x 4.30" x 1.97"
• Input transient & ESD compliance to EN61000-4-2/-3/-4
• Greater than 134,000 hours MTBF
• Remote sense and overvoltage protection on single
• Options include overtemperature protection,
(177.8 x 109.2 x 50.0 mm)
output units and main output of multiple output units
Power Fail signal, chassis, & cover
MAP110 AC-DC Series Data Sheet
REGULATION
REGULATION
0.2%
0.2%
0.2%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
LINE
LINE
REGULATION
REGULATION
0.5%
0.5%
LOAD
0.5%
1.5%
0.5%
0.5%
0.5%
1.5%
0.5%
1%
LOAD
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
RIPPLE & NOISE
RIPPLE & NOISE
%p-p (NOTE 2)
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
11.97V to 12.03V
23.94V to 24.06V
11.97V to 12.03V
14.96V to 15.04V
23.94V to 24.06V
11.97V to 12.02V
23.95V to 24.05V
-11.4V to -12.6V
-4.75V to -5.25V
-11.4V to -12.6V
-11.4V to -12.6V
-14.3V to -15.7V
-4.75V to -5.25V
-14.3V to -15.7V
5.09V to 5.11V
5.09V to 5.11V
11.4V to 12.6V
5.09V to 5.11V
11.4V to 12.6V
5.09V to 5.11V
5.09V to 5.11V
14.3V to 15.7V
5.09V to 5.11V
INITIAL SETTING
INITIAL SETTING
ACCURACY
ACCURACY

Related parts for MAP110-4200

MAP110-4200 Summary of contents

Page 1

... Description Power-One’s MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint ...

Page 2

... Fixed MAP110-4011 -12V Fixed +24V Fixed +5V 4.75V to 5.25V +12V Fixed MAP110-4015 -15V Fixed +15V Fixed +12V 11.55V to 12.45V +24V Fixed MAP110-4200 -12V Fixed +5V Fixed +3.3V 3.2V to 3.4V +5V Fixed MAP110-4300 -12V Fixed (Note 3) +12V Fixed +3.3V 3.2V to 3.4V +5V Fixed MAP110-4305 -5V ...

Page 3

... NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4 and V4 are unused, no minimum load is necessary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet MAP110-1005 MAP110-1012 MAP110-1024 MAP110-4200 MAP110-4300 All other models. Page MIN NOM MAX ...

Page 4

... Warning time increases at reduced load levels. Thermal Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature Shutdown condition. Automatic recovery. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet At 100% load: At 50% load: Page MIN NOM ...

Page 5

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet OVERALL WEIGHT: 1.3 lb (0.59 kg) Page NOTE 1 ...

Related keywords