DK1601-9ER POWER ONE, DK1601-9ER Datasheet

DK1601-9ER

Manufacturer Part Number
DK1601-9ER
Description
Manufacturer
POWER ONE
Type
Step Downr
Datasheet

Specifications of DK1601-9ER

Input Voltage
110V
Output Voltage
24V
Output Power
150
Screening Level
Commercial
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
71C
Product Length (mm)
171.9mm
Product Depth (mm)
111mm
Mounting Style
Screw
Number Of Outputs
1
Lead Free Status / RoHS Status
Not Compliant
Description
The K Series of DC-DC and AC-DC converters represents a
broad and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LK models can be powered by
DC or AC with a wide-input frequency range (without PFC).
The converter inputs are protected against surges and
transients. Input over- and undervoltage lockout circuitry
disables the outputs, if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-
on.
All outputs are open- and short-circuit proof, and are protected
against overvoltages by means of built-in suppressor diodes.
The output can be inhibited by a logic signal applied to pin 18
(i). The inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.
Table of Contents
Description ......................................................................... 1
Model Selection .................................................................. 2
Functional Description ....................................................... 4
Electrical Input Data ........................................................... 5
Electrical Output Data ......................................................... 8
Auxiliary Functions ............................................................ 12
BCD20002-G Rev AB, 12-Jul-2010
80
3.2"
16 TE
®
168
6.6"
111
4.4"
3 U
Page
Page 1 of 31
Features
Full input-to-output, input-to-case, output-to-case, and output
to output isolation is provided. The converters are designed,
built, and safety-approved to the international safety standards
IEC/EN 60950-1. They are particulary suitable for railway
applications and comply with EN 50155 and EN 50121-2-3.
The case design allows operation at nominal load up to 71 °C
in a free-air ambient temperature. If forced cooling is provided,
the ambient temperature may exceed 71 °C, but the case
temperature must remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which
disables the outputs when the case temperature T
the limit. The outputs are automatically re-enabled, when the
temperature drops below the limit.
Various options are available to adapt the converters to
individual applications.
The converters may either be plugged into a 19 " rack system
according to IEC 60297-3, or be chassis mounted. They are
ideally suited for Railway applications.
Electromagnetic Compatibility (EMC) .............................. 15
Immunity to Environmental Conditions ............................ 17
Mechanical Data ............................................................... 18
Safety and Installation Instructions .................................. 20
Description of Options ..................................................... 23
Accessories ...................................................................... 30
150 Watt DC-DC and AC-DC Converters
• RoHS lead-free-solder and lead-solder-exempted
• Class I equipment
• Extremly wide input voltage ranges from 8 to 385 VDC,
• Input over- and undervoltage lockout
• Adjustable output voltage with remote on/off
• 1 or 2 outputs: SELV, no load, overload, and short-
• Rectangular current limiting characteristic
• Immunity accord. to IEC 61000-4-2, -3, -4, -5, -6
• PCBs protected by lacquer
• Very high reliability
Safety according to IEC/EN 60950-1, UL/CSA 60950-1
Important: For applications requiring compliance with IEC/EN
61000-3-2 (harmonic distortion), please use our LK4000 or
LK5000 Series with incorporated power factor correction (PFC).
products are available.
and 85 to 264 VAC, 47 to 440 Hz
circuit proof
K Series Data Sheet
www.power-one.com
C
exceeds
Page

Related parts for DK1601-9ER

DK1601-9ER Summary of contents

Page 1

U 80 168 3.2" 6.6" Description The K Series of DC-DC and AC-DC converters represents a broad and flexible range of power supplies for use in advanced electronic systems. Features include high efficiency, high ...

Page 2

... VDC [%] 67 – 385 VDC DK1001-7R 80 --- DK1301-7R 83 EK1301-7R 5 DK1740-7R 83 --- DK1501-7R 85 EK1501-7R DK1601-7R 86 EK1601-7R DK2320-7R 81 EK2320-7R DK2540-7R 83 EK2540-7R DK2660-7R 84 EK2660-7R DK2740- --- = 25 °C. Typical values are approximately 2% better controlled by the battery temperature sensor (see Accessories) within 12.62 – 14.12 V. Options ...

Page 3

Part Number Description Operating input voltage – 35 VDC ................................................................ AK 14 – 70 VDC .............................................................. BK 20 – 100 VDC ............................................................ FK 28 – 140 VDC ........................................................... CK 44 – 220 VDC .......................................................... DK ...

Page 4

Functional Description The input voltage is fed via an input fuse, an input filter, a bridge rectifier (LK models only), and an inrush current limiter to the input capacitor. This capacitor sources a single- transistor forward converter with a ...

Page 5

Electrical Input Data General Conditions – 25°C, unless T is specified – Pin 18 connected to pin 14, V adjusted – Sense line pins S+ and S– connected to Vo+ and Vo– ...

Page 6

Input Transient Protection A suppressor diode or a VDR (depending upon the input voltage range) together with the input fuse and a symmetrical input filter form an effective protection against high input transient voltages which, typically occur in most ...

Page 7

Input Under-/Overvoltage Lockout If the input voltage remains below approx. 0.8 V approx. 1 internally generated inhibit signal i max disables the output(s). When checking this function, the absolute maximum input voltage V Between V and ...

Page 8

Electrical Output Data General Conditions: – °C, unless T is specified – Pin 18 (i) connected to pin 14 (S– or Vo1–), R input not connected, V – Sense line pins 12 (S+) and ...

Page 9

Table 6a: Output data of double-output models. General conditions as per table 5. Model Nom. output voltage Characteristics Conditions Output voltage nom 8 Overvoltage protection (suppressor diode) 2 Output current nom. I ...

Page 10

Thermal Considerations If a converter is located in free, quasi-stationary air (convection cooling) at the indicated maximum ambient temperature T (see table Temperature specifications) and A max is operated at its nominal input voltage and output power, the temperature ...

Page 11

± nom 1 0.5 10 µs 0 Fig. 10 Typical dynamic load regulation of V Output Regulation of Double-Output Models Output 1 is under normal ...

Page 12

Auxiliary Functions Inhibit for Remote On/Off The outputs may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied between the inhibit input i (pin 18) and pin 14 (S– or Vo1–). In systems with ...

Page 13

Adjustment by means of an external resistor: Depending upon the value of the required output voltage, the resistor shall be connected either: Between pin 16 and pin 14 to achieve an output voltage adjustment range of approximately 0 ...

Page 14

Display Status of LEDs V > 0.95 to 0.98V o1 o1 adj min V > 0.95 to 0.98V o1 o1 adj inh ...

Page 15

Electromagnetic Compatibility (EMC) A metal oxide VDR together with the input fuse and an input filter form an effective protection against high input transient Electromagnetic Immunity Table 9: Electromagnetic immunity (type tests) Phenomenon Standard Level Supply related RIA 12 ...

Page 16

... TÜV-Divina, ESVS 30:R&S, BBA 9106/UHALP 9107:Schwarzb., QP, 2009-11-20 Testdistance 10 m, BK1601- <25 dbµV/m 50 100 200 500 and I i nom o nom TÜV-Divina, ESVS 30:R&S, BBA 9106/UHALP 9107:Schwarzb., QP, 2009-11-20 Testdistance 10 m, DK1601-9ERB1 =110 = <25 dbµV/m 50 100 200 500 and I i nom o nom www.power-one.com EN 55011 A ...

Page 17

Immunity to Environmental Conditions Table 10: Mechanical and climatic stress Test Method Standard Cab Damp heat IEC/EN 60068-2-78 steady state MIL-STD-810D sect. 507.2 Kb Salt mist, cyclic IEC/EN 60068-2-52 (sodium chloride NaCl solution) Fc Vibration IEC/EN 60068-2-6 (sinusoidal) MIL-STD-810D ...

Page 18

Mechanical Data Dimensions in mm. The converters are designed to be inserted into a 19" rack, 160 mm long, according to IEC 60297-3. 159 Measuring point of case temperature T 50 (171.0 .... 171.9) Front plate Main face 168.5 ...

Page 19

Fig. 25 Option B1: Aluminium case K02 with small cooling plate; black finish (EP powder coated). Suitable for mounting with access from the backside. Total weight approx. 1.2 kg. 5 47.2 38.5 11.8 Fig. 26 Option B: ...

Page 20

Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 or H15- S4 connector. The protective earth is connected by a leading pin (no. 24), ...

Page 21

Notes: – If the inhibit function is not used, pin no. 18 (i) should be connected with pin no enable the output(s). – Do not open the converters, or warranty will be invalidated. – Due to high ...

Page 22

Safety of Operator-Accessible Output Circuits If the output circuit of a DC-DC converter is operator- accessible, it shall be an SELV circuit according to the standard IEC 60950-1. The following table shows some possible installation configurations, compliance with which ...

Page 23

If the output circuit of an AC-DC converter is operator- accessible, it shall be an SELV circuit according to standard IEC 60950-1. Fuse ~ Mains Fuse ~ Earth connection Fig. 29 Schematic safety concept. Use earth connection as per ...

Page 24

E Inrush Current Limitation CK/DK/EK/LK models may be supplemented by an electronic circuit (option E, replacing the standard built-in NTC resistor) LK models Control R S Fig. 30 Block diagram of option E Current limiting resistance ...

Page 25

T Current Sharing This option ensures that the approximately shared between converters, hence increasing system reliability. To use this facility, simply interconnect the T pins of all converters and make sure that the reference for the T signal, pin ...

Page 26

Table 20: Undervoltage monitoring functions Output type Monitoring JFET NPN yes D3 D7 yes yes yes yes - - DD yes 1 Threshold level adjustable by ...

Page 27

Table 23: D-output logic signals Version of D D1, D2, D3, D4, D0 D5, D6, D7, D8, D9, DD Input voltage monitoring V NPN high low high I ...

Page 28

Table 24: Option V: Factory potentiometer setting of V Model AK 9 ACFAIL signal (VME) Available for units with V = 5.1 V only. o nom This option defines an undervoltage ...

Page 29

NPN open collector Fig. 40 Output configuration of options V0, V2 and V3 Input voltage monitoring high V V low high V V low 0 t ...

Page 30

B, B1, B2 Cooling Plate Where a cooling surface is available, we recommend the use of a cooling plate instead of the standard heat sink. The mounting system should ensure that the maximum case temperature T is not exceeded. ...

Page 31

Cable connector housing (cable hood) KSG-H15/H15S4 [HZZ00141] as screw version. Also available as retention clip version [HZZ00142 fully metallic housing. – DIN-rail mounting assembly DMB-K/S [HZZ0615] – Wall-mounting plate K02 [HZZ01213] for models with option ...

Related keywords