CPD200-4530G POWER ONE, CPD200-4530G Datasheet

DC/DC Converters & Regulators 36-75Vin 200W 5V20A 3.3V20A/12V2.5A

CPD200-4530G

Manufacturer Part Number
CPD200-4530G
Description
DC/DC Converters & Regulators 36-75Vin 200W 5V20A 3.3V20A/12V2.5A
Manufacturer
POWER ONE
Type
Step Downr
Datasheet

Specifications of CPD200-4530G

Input Voltage
48V
Screening Level
Commercial
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Number Of Outputs
4
Output Power
200 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
20 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
2.5 A
Package / Case Size
162.5 mm x 100 mm x 40.6 mm
Output Voltage
5 V to 12 V
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
Description
The CPA and CPD Series are highly reliable power supplies
for CompactPCI
communications, industrial, military, aerospace, and other
applications. These power supplies offer high power density
in plug-in modules that meet the requirements of the
PICMG
systems.
The converters use the patented EDGE
provide important advantages such as flexible output
power, extremely high efficiency, excellent reliability, full
input-to-output isolation, negligible inrush current, hot-swap
capability, soft start, and overtemperature protection.
The input is protected by a transient suppressor (varistor)
against surges and transients occurring on the source lines
and cover an operating input voltage range from either 90 to
264 VAC or 36 to 75 VDC.
The outputs are protected against continuous overload,
open-circuit, and short-circuit. Full n+1 redundant operating
mode is made possible by integrated ORing FETs or ORing
Table of Contents
Description ....................................................................... 1
Model Selection ............................................................... 2
Functional Description ..................................................... 3
Electrical Input Data ......................................................... 5
Electrical Output Data ...................................................... 7
Auxiliary Functions ......................................................... 10
BCD20005-G Rev. AF, 18-Aug-10
®
power interface specification for CompactPCI
®
systems, which are increasingly used in
®
200 – 550 Watt CompactPCI
TM
40.4
1.6"
8 HP
technology and
162.5
6.4"
Page
Page 1 of 19
233.3
7.8"
6 U
®
Features
Electromagnetic Compatibility (EMC) ............................ 13
Immunity to Environmental Conditions .......................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Options ........................................................................... 19
• RoHS lead-free-solder and lead-solder-exempted
• Compliant with PICMG
• Wide range DC or AC input with PFC
• Extremely high efficiency and high power density
• Low inrush current
• 4 high current outputs with flexible load distribution
• Integrated ORing FETs / diodes for true redundancy
• Inhibit and enable inputs
• Remote sense lines
• Single-wire current share function for 3 outputs
• Hot-swap capability
• 47-pin connector, type Positronic
• Overtemperature, overvoltage, overcurrent, and
products are available
overpower protection
Safety according to IEC/EN 60950-1 2
UL/CSA 60950-1 2
®
AC-DC and DC-DC Converters
CPA, CPD Series Data Sheet
nd
Ed.
®
CompactPCI
40.6
1.6"
8 HP
www.power-one.com
®
nd
specifications
162.5
6.4"
Ed. and
100
3.94"
3 U
Page

Related parts for CPD200-4530G

CPD200-4530G Summary of contents

Page 1

Watt CompactPCI ® Description The CPA and CPD Series are highly reliable power supplies ® for CompactPCI systems, which are increasingly used in communications, industrial, military, aerospace, and other applications. These power supplies offer high power density ...

Page 2

... The converters are designed as two or three separate forward converters with fixed switching frequency and synchronous rectifiers at their output. LEDs on the front panel and various warning signals display Model Selection Table 1: Standard models 3 Model Output No nom [V] CPD200-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPD250-4530 Vo1 5.0 Vo2 3 ...

Page 3

... Only CPA models have a bridge rectifier and a boost converter Fig. 1a Block diagram of CPA/CPD200 and CPA/CPD250 models. For the pin allocation, see Mechanical Data. BCD20005-G Rev. AF, 18-Aug-10 ® AC-DC and DC-DC Converters nominal output voltages and output currents, degree of protection, batch no., serial no., and data code including production site, modification status, and date of production ...

Page 4

Watt CompactPCI ® technique and proprietary leading and trailing-edge pulse- width modulation. It has a proven track record in high- availability power solutions. The switching frequency is typically 135 kHz. Some models (CPx200/250 version V117, CPA500/550 version ...

Page 5

... CPD/CPA250 3 nd First value for CPA500, 2 value for CPA550 4 Short interruption of V without affecting the outputs i 5 CPA200/250 with version V117 or higher, as they are equipped with an input voltage trigger BCD20005-G Rev. AF, 18-Aug-10 CPD200/250 Conditions min typ – max T – ...

Page 6

... Littlefuse FKS, 166.7000.525 CPA500/550 250 Schurter MXT250, 0034.6925 To avoid unwanted power losses, the CPD200/250 models are not protected against reverse polarity at the input by a serial diode, but only with an antiparallel diode. In the case of reversed input voltage, the input fuse will blow; however no further damage will occur ...

Page 7

... V Temperature coefficient min of output voltage 0 – First value for CPD200/CPA200, second value for CPD250/CPA250 2 Minimum load is only required to maintain regulation of output Vo4 3 Droop characteristic for passive current sharing 4 Measured with a probe according to IEC/EN 61204, annex A BCD20005-G Rev. AF, 18-Aug-10 Vo1 (5.0 V) ...

Page 8

Watt CompactPCI ® General conditions for table 5: – °C, unless T is specified – CPD500, CPA500: 300 LFM (1.5 m/s), CPA550: 400 LFM (2 m/s) – Sense lines connected directly at ...

Page 9

Watt CompactPCI ® Hold-up Time of CPD Models For extended hold-up time of CPD models, use external output capacitors or decoupling diodes and input capacitors of adequate size. Formula for additional external input capacitor: 2 • P ...

Page 10

Watt CompactPCI ® nom 300 LFM = 1.5 m/s (CPA/CPD500) 400 LFM = 2 m/s (CPA550) JM012a 1.0 Convection cooling in upright position CPA/CPD500 0.6 0.5 CPA550 min ...

Page 11

... nom BCD20005-G Rev. AF, 18-Aug-10 The threshold levels for V CPD models and 80 – 90 VAC for CPA models. Note: CPD200/250 (and CPA200/250 up to version V116) changes from high DEG# provide only the signal FAL#, but the converter is not inhibited. falls C Note remains for typ ...

Page 12

Watt CompactPCI ® Active Current Sharing for Vo1, Vo2, Vo3 The current share facility, consisting of a single-wire link, should be used, where several converters are operated in parallel connection, for example, high reliability n+1 redundant systems ...

Page 13

Watt CompactPCI ® Electromagnetic Compatibility (EMC) A metal oxide VDR together with the input fuse and a filter form an effective protection against high input voltage Electromagnetic Immunity Table 8: Immunity type tests Phenomenon Standard Level Electrostatic ...

Page 14

... Watt CompactPCI ® Electromagnetic Emission Radiated and conducted emissions comply with EN 55011/ 55022, class A. In addition, CPD500 and CPA500/550 meet conducted emissions class B. dBµV CPD200, B738613, 50807-TU, Peak L, Conducted 0. MHz, Divina, 7-Mar- 0.2 0 Fig. 13a Typical disturbance voltage (peak) at the negative input according to EN 55022, measured at V (CPD200-4530) ...

Page 15

... Shock IEC/EN 60068-2-27 (half-sinusoidal) Eb Bump IEC/EN 60068-2-29 (half-sinusoidal) Fda Random vibration IEC/EN 60068-2-35 wide band, CPD200/250, CPA200/250 reproducibility high IEC/EN 60068-2-35 CPD500, CPA500/550 Drop test Converter in proper packing CPD200/250 1 Version V106 or higher Temperatures Table 10: Temperature specifications, valid for an air pressure of 800 – 1200 hPa (800 – 1200 mbar) ...

Page 16

... Watt CompactPCI ® Mechanical Data Dimensions in mm (inches) Fig. 15 CPA200/250 and CPD200/250. Overall size: 162.5 x 128.7 x 40.6 mm. Weight: 0.8 kg (0.098") Fig. 16 View of the connector Fig. 17 CPD500 and CPA500/550. Overall size: 223.4 x 162.5 x 40.6 mm. Weight: 1.65 kg (0.098") BCD20005-G Rev. AF, 18-Aug-10 ...

Page 17

Watt CompactPCI ® Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the Positronic connector. Pin no. 45 (protective earth leading pin, ...

Page 18

Watt CompactPCI ® Table 13: Isolation Characteristic Electric Actual factory test 1 s strength AC test voltage equivalent test to factory test Insulation resistance at 500 VDC 1 According to IEC/EN 60950, subassemblies connecting input to output ...

Page 19

Watt CompactPCI ® Options L: Output Current Latch All CPA/CPD models exhibit a latching shutdown, which is activated if only one output voltage is too high; see Output Characteristic and Protection. If option L is fitted, this ...

Related keywords