7-1393243-9

Manufacturer Part Number7-1393243-9
DescriptionElectromechanical Relay DPDT 15A 230VAC 32.5KOhm Through Hole
ManufacturerTE Connectivity
TypePower Relay
7-1393243-9 datasheet
 


Specifications of 7-1393243-9

Contact ArrangementDPDTAc Coil Voltage230 V
MountingThrough Hole  
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (601Kb)Embed
Next
General Purpose Relays
PCB Relays
Power PCB Relay RT2
2 pole 8A, 2 form C (CO) or 2 form A (NO) contacts
n
DC or AC coil
n
5kV/10mm coil-contact, reinforced insulation
n
Ambient temperature up to 85°C
n
WG version: product in accordance to IEC60335-1
n
Reflow version: for THR (Through-Hole Reflow) soldering process
n
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
Approvals
VDE REG.-Nr. 6106, cULus E214025, cCSAus 14385, BEAB C0786
Technical data of approved types on request
Contact Data
Contact arrangement
2 form C (CO) or 2 form A (NO)
Rated voltage
Max. switching voltage
Rated current
Limiting continuous current
Limiting making current, max. 4s, duty factor 10%
Breaking capacity max.
Contact material
AgNi 90/10, AgNi 90/10 gold plated,
Frequency of operation, with/without load
DC coil
AC coil
Operate/release time max., DC coil
Bounce time max., DC coil, form A/form B
Electrical endurance
see electrical endurance graph
Contact ratings
Type
Contact
Load
IEC 61810
RT424 DC coil C (CO)
8A, 250VAC, cosφ=1, 85°C
RT444 AC coil A (NO)
8A, 250VAC, cosφ=1, 70°C
RT424 AC coil C (CO)
8A, 250VAC, cosφ=1, 70°C
UL 508
RT424 DC coil A/B (NO/NC) 10A, 250VAC, gen. purpose, 85°C
RT424 DC coil A/B (NO/NC) 1/2hp, 240VAC, 85°C
RT424 DC coil A/B (NO/NC) Pilot duty, B300, R300, 85°C
EN60947-5-1
RTE24 DC coil A/B (NO/NC) AC15, 250VAC, 3A
RTE24 DC coil A/B (NO/NC) DC13, 24VDC, 2A
RTE24 DC coil A/B (NO/NC) DC13, 250VDC, 0.2A
EN60730-1
RT424 DC coil A/B (NO/NC) 6(2)A, 250VAC, 85°C
1) For reflow solderable versions: actual contact performance may be influenced by the
reflow soldering process.
09-2010, Rev. 0910
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
www.tycoelectronics.com
together with the ‘Definitions’ section.
© 2010 Tyco Electronics Ltd.
Contact Data
Mechanical endurance
DC coil
DC coil, reflow version
AC coil
AC coil, reflow version
250VAC
400VAC
Coil Data
8A, UL: 10A
8A, UL: 10A
Coil voltage range, DC coil/AC coil
15A
Operative range, IEC 61810
2000VA
Coil insulation system according UL
AgSnO
Coil versions, DC coil
2
Coil
360/72000h
-1
code
-1
360/36000h
8/6ms
005
4/10ms
006
1)
009
012
024
Cycles
048
060
10x10
3
110
50x10
3
2) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient
temperature +23°C. Other coil voltages on request.
3
30x10
Coil versions, AC coil 50Hz
20x10
3
Coil
3
1x10
code
6x10
3
524
6.050
615
6.050
620
6.050
700
730
100x10
3
3) Coil resistance ±10%. All figures are given for coil without pre-energization, at ambient
temperature +23°C, 50Hz. Other coil voltages on request.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
V
Z
b B
(continued)
>30x10
6
operations
>10x10
6
operations
>5x10
6
operations
>2x10
6
operations
5 to 110VDC / 24 to 230VAC
2
class F
Rated
Operate
Release
Coil
voltage
voltage
voltage
resistance
VDC
VDC
VDC
Ω±10%
5
3.5
0.5
62
6
4.2
0.6
90
9
6.3
0.9
200
12
8.4
1.2
360
24
16.8
2.4
1440
48
33.6
4.8
5520
60
42.0
6.0
8570
110
77.0
11.0
28800
Rated
Operate
Release
Coil
voltage
voltage
voltage
resistance
VAC
VAC
VAC
Ω±15%
24
18.0
3.6
350
115
86.3
17.3
8100
120
90.0
18.0
8800
200
150.0
30.0
24350
230
172.5
34.5
32500
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
Schrack
F0149-C
Rated coil
power
2)
mW
403
400
400
400
400
417
2)
420
2)
420
Rated coil
power
3)
VA
3)
0.76
0.76
0.75
0.76
0.74
1

7-1393243-9 Summary of contents

  • Page 1

    ... Reflow version: for THR (Through-Hole Reflow) soldering process n Typical applications Boiler control, timers, garage door control, POS automation, interface modules Approvals VDE REG.-Nr. 6106, cULus E214025, cCSAus 14385, BEAB C0786 Technical data of approved types on request Contact Data Contact arrangement 2 form C (CO form A (NO) Rated voltage Max ...

  • Page 2

    ... Vibration resistance (functional), form A/form B contact 300Hz Shock resistance (destructive) Dimensions THT version Process conditions for Reflow soldering according to EN61760-1 2 09-2010, Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.tycoelectronics.com together with the ‘Definitions’ section. ...

  • Page 3

    ... Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. Schrack 024 4-1393243-3 5-1393243-9 6-1393243-1 6-1393243-3 7-1415538-8 6-1393243-8 7-1415538-7 7-1393243-0 7-1393243-3 7-1393243-5 7-1393243-6 7-1393243-8 7-1393243-9 7-1415525-1 8-1393243-0 8-1393243-2 8-1393243-5 9-1393243-7 9-1393243-9 1393243-1 1393243-2 1393243-4 1-1393243-0 1-1393243-1 1-1393243-4 1-1393243-5 1-1393243-7 1-1393243-8 1-1393243-9 ...