8-1393104-1 TE Connectivity, 8-1393104-1 Datasheet

Electromechanical Relay 3PDT 10A 110VDC 10KOhm Socket

8-1393104-1

Manufacturer Part Number
8-1393104-1
Description
Electromechanical Relay 3PDT 10A 110VDC 10KOhm Socket
Manufacturer
TE Connectivity
Type
Industrial Relayr
Datasheet

Specifications of 8-1393104-1

Contact Arrangement
3PDT
Dc Coil Voltage
110 V
Coil Current
11 mA
Mounting
Socket
Relay Construction
Non-Latching
Coil Voltage Dc
110V
Contact Form
3 Form C
Coil Resistance
10kohm
Contact Current Rating
10A
Contact Material
Silver Cadmium Oxide
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
34.9mm
Product Depth (mm)
37.3mm
Product Length (mm)
48.8mm
Pin Count
11
Mounting Style
Socket
Termination Style
11-Pin Circular Plug
Lead Free Status / Rohs Status
Compliant
Features
• Industry standard octal-type termination for quick installation.
• Contact arrangements from 1 Form C (SPDT) to 3 Form C (3PDT).
• Indicator lamp and push-to-test options available on certain models.
• The KRPA is the automated manufactured version of the KRP .
Contact Data @ 25°C
Arrangements: See Ordering Information Table.
Materials: Silver or silver-cadmium oxide, with or without gold flashing.
Expected Life: 10 million operations min., mechanical; 100,000
KA, KRP , KRPA
KRP , KRPA
KA UL Contact Ratings
Initial Dielectric Strength
Between Open Contacts: 500V rms.
Between All Elements: 1,500V rms.
Dimensions are shown for
reference purposes only.
Note: See KRPA, KRP , KA Ordering Information table.
1
2
Contact Code
Contact Code
Contact Code
Listed by C.S.A. for 5A @ 120VAC 80% PF
Listed by C.S.A. for 10A @ 120VAC 80% PF
Y
(Silver)
G&N
(Silver-Cad.
Oxide)
G&N
KRPA
G
Y
Y
operations min. @ rated loads.
Arrangement
Series
Factory Ratings
KA
KA
1, 2, 3 Poles
1, 2, 3 Poles
1
2
UL/CSA Contact Ratings @ 25°C
Arrangement
1, 2, 3 Poles
1, 2, 3 Poles
KRP
5A @ 120VAC, 3A @ 240VAC,
1/10 HP @ 120VAC, 1/6 HP @ 240VAC
10A @ 120VAC, 6A @ 240VAC
1/6 HP @ 120VAC, 1/3 HP @ 240VAC
10A @ 28VDC, 120VAC, 80% PF
6A @ 250VAC
5A @ 28VDC, 120VAC, 80% PF
Contact Ratings
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Contact Rating
5A @ 120VAC
3A @ 240VAC
1/10HP @ 120VAC
1/6HP @ 240VAC
10A @ 240VAC
1/2 HP @ 240VAC
1/3HP @ 120VAC
Contact Rating
KA
PDF Revised 9-03
Catalog 1308242
Specifications and availability
subject to change.
KRPA, KRP , KA, KR
5 to 10 Amp
General Purpose Relay
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Operate Data @ 25°C
Must-Operate Voltage:
Operate Time (Excluding Bounce):
Release Time (Excluding Bounce):
Environmental Data
Temperature Range:
Mechanical Data
Termination: Open Models: Solder terminals.
Weight: KA: 1.7 oz. (48.2g) approximately.
Coil Data @ 25°C
Duty Cycle: Continuous.
Initial Insulation Resistance: KRP , KRPA - 1000 Megohms, min.
Coil Data @ 25°C
KRP
KRPA
KA
Open Models: AC: -45°C to +70°C.
Enclosed Models: AC: -45°C to +55°C.
DC
Coils
AC
Coils
DC: 75% or less of nominal voltage.
AC: 85% or less of nominal voltage.
15 milliseconds typical @ nominal voltage.
10 milliseconds typical @ nominal voltage.
File E29244, E22575
File LR15734
KRPA, KRP: 3.0 oz. (85g) approximately.
Nominal
Voltage
AC
DC
AC
DC
Enclosed Models: Octal-type plug.
220
120
240
110
24
48
24
12
12
6
6
Enclosure: Transparent polycarbonate.
DC: -45°C to +85°C.
125mW per movable arm
DC: -45°C to +70°C.
Nominal Power
DC Resistance ( )
Use 110V relay with 10,000
1.2W
2VA
2VA
KA - 100 Megohms, min.
10,000
±10%
2,250
1,800
9,110
120
472
32
24
85
6
Maximum Power
Enclosed Models - 4VA
Enclosed Models - 3W
Open Models - 4VA
Open Models - 4W
series
5W Resistor in series
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Nominal Coil
Current (mA)
188
335
100
168
51
26.6
84
11.5
17 .5
8.75
P&B
737

Related parts for 8-1393104-1

8-1393104-1 Summary of contents

Page 1

... HP @ 120VAC, 1 240VAC 10A @ 120VAC 240VAC 1 120VAC, 1 240VAC 1 Listed by C.S.A. for 5A @ 120VAC 80 Listed by C.S.A. for 10A @ 120VAC 80% PF Note: See KRPA, KRP , KA Ordering Information table. Initial Dielectric Strength Between Open Contacts: 500V rms. Between All Elements: 1,500V rms. Dimensions are shown for Dimensions are in inches over reference purposes only ...

Page 2

... KA-14AY-120 KRP-14AN-120 KA-14DG-24 KRP-14AY-120 KA-14DG-110 KRP-14DG-12 KRP-5AG-120 KRP-14DG-24 KRP-11AG-24 KRP-14DG-110 KRP-11AG-120 KRP-14DN-24 KRP-11AG-240 KRPA-5AG-24 Dimensions are shown for 738 reference purposes only. Catalog 1308242 PDF Revised 9-03 B KRPA Typical Part No Form C (3PDT KRPA-11AY-240 KRPA-5AG-120 KRPA-11DG-6 KRPA-5AY-120 KRPA-11DG-12 KRPA-5DG-6 KRPA-11DG-24 KRPA-5DG-12 KRPA-11DG-48 ...

Page 3

... Many uses in automation controls and other applications requiring high current switching. Contact Data @ 25°C Arrangement: 1 Form X (SPST - NO - DM). Ratings: UL Rating: 20A @ 120VAC, 3 120VAC. Factory Rating: 20A @ 120VAC, 80% PF 120/240VAC. Material: Twin, silver-cadmium oxide. Expected Life: 2.5 million operations min., mechanical. 100,000 operations at rated contact load. ...

Page 4

... Wiring Diagrams (Bottom Views) KA KR5 KAP5 KRP5 KRPA5 Dimensions are shown for 740 reference purposes only. Catalog 1308242 PDF Revised 9-03 1.468 MAX. (37 .29) .15 .312 (3.8) (7 .92) For KRP3-H Hold-Down Spring 20C176 KRPA & KRP 20C206 KAP and KRP3 KAP11 KAP14 KRP11 KRP14 KRPA11 ...

Page 5

... Top View 2.060 (52.32 .312 TYP . (7 .92) 2.332 (59.22) 27E123 10A, 300VAC 11-pin 1.030 (26.16) .648 (16.46) 2.385 MAX. (60.58) + .210 TYP . (5.33) 1.188 (30.18) 1.156 (29.36) 2.322 MAX. (58.98) Terminal Location Specifications and availability subject to change. Terminal Location Top View ...