GATED TRIAC NON-ISOL 25.0A 600V

 

Q6025R6

Manufacturer Part NumberQ6025R6
DescriptionGATED TRIAC NON-ISOL 25.0A 600V
ManufacturerLittelfuse / Teccor Brand Thyristors
Q6025R6 datasheets

Availability: By request

International delivery:

Warranty: 60 days

Shipping & payment terms

Added to cart

 

Specifications of Q6025R6

Triac TypeAlternistor - SnubberlessMounting TypeThrough Hole
ConfigurationSingleCurrent - Hold (ih) (max)100mA
Voltage - Off State600VCurrent - Gate Trigger (igt) (max)80mA
Current - Non Rep. Surge 50, 60hz (itsm)208A, 250ACurrent - On State (it (rms)) (max)25A
Voltage - Gate Trigger (vgt) (max)2.5VPackage / CaseTO-220-3
Current - On State (it (rms) (max)25ALead Free Status / RoHS StatusLead free / RoHS Compliant
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
Page 1/11

Download datasheet (273Kb)Embed
Next
Qxx25xx & Qxx25xHx Series
Agency Approval
Agency
Agency File Number
TO-220L, TO-218K, TO-218J &
Fastpak Packages: E71639
®
Main Features
Symbol
Value
I
25
T(RMS)
V
/V
1000
DRM
RRM
I
50 to 80
GT
Schematic Symbol
MT2
G
©2010 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Teccor
Teccor
®
®
brand Thyristors
brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Description
25 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Alternistor type devices only operate in quadrants I, II, & III
and are used in circuits requiring high dv/dt capability.
Features & Benefits
junctions
to 1000 V
Applications
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
Typical applications are AC solid-state switches, industrial
power tools, exercise equipment, white goods and
Unit
commercial appliances.
A
Alternistor Triacs (no snubber required) are used in
V
applications with extremely inductive loads requiring
highest commutation performance.
mA
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
MT1
117
Revised: May 10, 2010 09:33 PM
®
to 250 A
Qxx25xx & Qxx25xHx Series

Q6025R6 Summary of contents

  • Page 1

    ... Typical applications are AC solid-state switches, industrial power tools, exercise equipment, white goods and Unit commercial appliances. A Alternistor Triacs (no snubber required) are used in V applications with extremely inductive loads requiring highest commutation performance. mA Internally constructed isolated packages are offered for ease of heat sinking with highest isolation voltage ...

  • Page 2

    ... Amp Standard & Alternistor (High Commutation) Triacs Absolute Maximum Ratings – Standard Triac Symbol Parameter I RMS on-state current T(RMS) I Peak non-repetitive surge current TSM Value for fusing di/dt Critical rate-of-rise of on-state current I Peak gate current GTM P Average gate power dissipation G(AV) ...

  • Page 3

    ... Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs — Standard Triac Quadrant I – II – III MAX. IV TYP . I – II – III MAX ...

  • Page 4

    ... Amp Standard & Alternistor (High Commutation) Triacs Thermal Resistances Symbol R Junction to case (AC) (J-C) R Junction to ambient (J-A) Note voltage sensitivity Figure 1: Normalized DC Gate Trigger Current vs. Junction Temperature 2. 2.0 1. 1.0 0. 0.0 - Junction Temperature (T Figure 3: Normalized DC Holding Current vs. Junction Temperature 2.0 1. 1.0 0. 0.0 - Junction Temperature (T Qxx25xx & ...

  • Page 5

    ... Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs Figure 6: Maximum Allowable Case Temperature vs. RMS On-State Current 130 120 110 100 90 ...

  • Page 6

    ... Amp Standard & Alternistor (High Commutation) Triacs Soldering Parameters Reflow Condition - Temperature Min (T ) s(min) Pre Heat - Temperature Max (T ) s(max) - Time (min to max Average ramp up rate (Liquidus Temp peak Ramp-up Rate S(max Temperature (T ) (Liquidus) L Reflow - Temperature ( Peak Temperature ( Time within 5°C of actual peak ...

  • Page 7

    ... Nm). ©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs AREA (REF.) 0. Dimension 8.13 .320 A B 13. ...

  • Page 8

    ... Amp Standard & Alternistor (High Commutation) Triacs Dimensions — TO-263 (N Package) — MEASURING POINT MT2 GATE MT1 11.68 2.16 .460 .08 7.01 7.01 .276 .276 16.89 .66 8. 2.03 .080 6.60 .260 Dimensions — TO-218AC (K Package) — Isolated Mounting Tab T Measurement Point ...

  • Page 9

    ... Thick ness off all three copper-alloy terminals is .032" (0.81 mm). ©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs C Dimension D (diameter ...

  • Page 10

    ... Amp Standard & Alternistor (High Commutation) Triacs Product Selector Voltage Part Number 400V 600V Qxx25R5 X X Qxx25N5 X X Qxx25P5 X Qxx25RH5 X X Qxx25LH5 X X Qxx25NH5 X X Qxx25R6 X X Qxx25L6 X X Qxx25NH6 X X Qxx25J6 X X Qxx25K6 X X Packing Options Part Number Marking Qxx25R5 ...

  • Page 11

    ... Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs 0.63 0.1 7 (16.0) (4.0) Gate 0.0 9 DIA (1. ) MT1 / Cathode ...