Q6025L6 Littelfuse / Teccor Brand Thyristors, Q6025L6 Datasheet

GATED TRIAC ISOLATED 25.0A 600V

Q6025L6

Manufacturer Part Number
Q6025L6
Description
GATED TRIAC ISOLATED 25.0A 600V
Manufacturer
Littelfuse / Teccor Brand Thyristors
Datasheet

Specifications of Q6025L6

Triac Type
Alternistor - Snubberless
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
100mA
Voltage - Off State
600V
Current - Gate Trigger (igt) (max)
80mA
Current - Non Rep. Surge 50, 60hz (itsm)
208A, 250A
Current - On State (it (rms)) (max)
25A
Voltage - Gate Trigger (vgt) (max)
2.5V
Package / Case
TO-220-3 Isolated Tab
Current - On State (it (rms) (max)
25A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Q6025L6
Manufacturer:
SIEMENS
Quantity:
5 000
Part Number:
Q6025L6
Manufacturer:
TECCOR
Quantity:
20 000
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
©2010 Littelfuse, Inc
Symbol
Agency Approval
Main Features
Schematic Symbol
I
V
I
T(RMS)
GT
DRM
Agency
®
/V
RRM
Qxx25xx & Qxx25xHx Series
MT2
TO-220L, TO-218K, TO-218J &
Fastpak Packages: E71639
50 to 80
Value
Agency File Number
1000
25
G
Teccor
Teccor
25 Amp Standard & Alternistor (High Commutation) Triacs
MT1
Unit
mA
A
V
®
®
Revised: May 10, 2010 09:33 PM
brand Thyristors
brand Thyristors
117
Description
25 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Alternistor type devices only operate in quadrants I, II, & III
and are used in circuits requiring high dv/dt capability.
Features & Benefits
Applications
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
Typical applications are AC solid-state switches, industrial
power tools, exercise equipment, white goods and
commercial appliances.
Alternistor Triacs (no snubber required) are used in
applications with extremely inductive loads requiring
highest commutation performance.
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
to 1000 V
junctions
to 250 A
Qxx25xx & Qxx25xHx Series
®

Related parts for Q6025L6

Q6025L6 Summary of contents

Page 1

... Typical applications are AC solid-state switches, industrial power tools, exercise equipment, white goods and Unit commercial appliances. A Alternistor Triacs (no snubber required) are used in V applications with extremely inductive loads requiring highest commutation performance. mA Internally constructed isolated packages are offered for ease of heat sinking with highest isolation voltage ...

Page 2

... Amp Standard & Alternistor (High Commutation) Triacs Absolute Maximum Ratings – Standard Triac Symbol Parameter I RMS on-state current T(RMS) I Peak non-repetitive surge current TSM Value for fusing di/dt Critical rate-of-rise of on-state current I Peak gate current GTM P Average gate power dissipation G(AV) ...

Page 3

... Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs — Standard Triac Quadrant I – II – III MAX. IV TYP . I – II – III MAX ...

Page 4

... Amp Standard & Alternistor (High Commutation) Triacs Thermal Resistances Symbol R Junction to case (AC) (J-C) R Junction to ambient (J-A) Note voltage sensitivity Figure 1: Normalized DC Gate Trigger Current vs. Junction Temperature 2. 2.0 1. 1.0 0. 0.0 - Junction Temperature (T Figure 3: Normalized DC Holding Current vs. Junction Temperature 2.0 1. 1.0 0. 0.0 - Junction Temperature (T Qxx25xx & ...

Page 5

... Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs Figure 6: Maximum Allowable Case Temperature vs. RMS On-State Current 130 120 110 100 90 ...

Page 6

... Amp Standard & Alternistor (High Commutation) Triacs Soldering Parameters Reflow Condition - Temperature Min (T ) s(min) Pre Heat - Temperature Max (T ) s(max) - Time (min to max Average ramp up rate (Liquidus Temp peak Ramp-up Rate S(max Temperature (T ) (Liquidus) L Reflow - Temperature ( Peak Temperature ( Time within 5°C of actual peak ...

Page 7

... Nm). ©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs AREA (REF.) 0. Dimension 8.13 .320 A B 13. ...

Page 8

... Amp Standard & Alternistor (High Commutation) Triacs Dimensions — TO-263 (N Package) — MEASURING POINT MT2 GATE MT1 11.68 2.16 .460 .08 7.01 7.01 .276 .276 16.89 .66 8. 2.03 .080 6.60 .260 Dimensions — TO-218AC (K Package) — Isolated Mounting Tab T Measurement Point ...

Page 9

... Thick ness off all three copper-alloy terminals is .032" (0.81 mm). ©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs C Dimension D (diameter ...

Page 10

... Amp Standard & Alternistor (High Commutation) Triacs Product Selector Voltage Part Number 400V 600V Qxx25R5 X X Qxx25N5 X X Qxx25P5 X Qxx25RH5 X X Qxx25LH5 X X Qxx25NH5 X X Qxx25R6 X X Qxx25L6 X X Qxx25NH6 X X Qxx25J6 X X Qxx25K6 X X Packing Options Part Number Marking Qxx25R5 ...

Page 11

... Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor Teccor ® ® brand Thyristors brand Thyristors 25 Amp Standard & Alternistor (High Commutation) Triacs 0.63 0.1 7 (16.0) (4.0) Gate 0.0 9 DIA (1. ) MT1 / Cathode ...

Related keywords