Q4015L558 Littelfuse / Teccor Brand Thyristors, Q4015L558 Datasheet

no-image

Q4015L558

Manufacturer Part Number
Q4015L558
Description
TRIAC 400V 15A TO220
Manufacturer
Littelfuse / Teccor Brand Thyristors
Datasheet

Specifications of Q4015L558

Triac Type
Standard
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
70mA
Voltage - Off State
400V
Current - Gate Trigger (igt) (max)
50mA
Current - Non Rep. Surge 50, 60hz (itsm)
167A, 200A
Current - On State (it (rms)) (max)
15A
Voltage - Gate Trigger (vgt) (max)
2.5V
Package / Case
TO-220-3 Formed Leads, Isolated
Current - On State (it (rms) (max)
15A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Qxx15xx & Qxx16xHx Series
I
V
I
Agency Approval
Main Features
T(RMS)
GT (Q1)
Schematic Symbol
DRM
Agency
15 Amp Standard & 16 Amp Alternistor (High Commutation) Triacs
®
/V
Symbol
RRM
Qxx15xx & Qxx16xHx Series
MT2
400 to 1000
10 to 80
15 & 16
Value
Agency File Number
L Package : E71639
Teccor
G
Revised: November 1, 2010 05:04 PM
MT1
®
brand Thyristors
Unit
mA
A
V
107
Description
15 Amp and 16 Amp bi-directional solid state switch series
is designed for AC switching and phase control applications
such as motor speed and temperature modulation controls,
lighting controls, and static switching relays.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Alternistor type devices only operate in quadrants I, II, & III
and are used in circuits requiring high dv/dt capability.
Features & Benefits
• RoHS Compliant
• Glass – passivated
• Voltage capability up to
• Surge capability up to
• Electrically isolated
• Solid-state switching
Applications
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
Typical applications are AC solid-state switches, light
dimmers, power tools, lawn care equipment, home/brown
goods and white goods appliances.
Alternistor Triacs (no snubber required) are used in
applications with extremely inductive loads requiring
highest commutation performance.
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
junctions
1000 V
200 A
“L-Package” is UL
recognized for 2500Vrms
eliminates arcing or
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
• No contacts to wear
• Restricted (or limited) RFI
• Requires only a small
contact bounce that
create voltage transients
out from reaction of
switching events
generation, depending
on activation point in sine
wave
gate activation pulse in
each half-cycle
©2010 Littelfuse, Inc
®

Related parts for Q4015L558

Q4015L558 Summary of contents

Page 1

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Qxx15xx & Qxx16xHx Series Agency Approval Agency Agency File Number L Package : E71639 ® Main Features Symbol Value I 15 & 16 T(RMS 400 to 1000 DRM RRM (Q1) Schematic Symbol MT2 Qxx15xx & Qxx16xHx Series Teccor brand Thyristors ® ...

Page 2

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Absolute Maximum Ratings — Standard Triac Symbol I RMS on-state current (full sine wave) T(RMS) Non repetitive surge peak on-state current I (full cycle, T TSM Value for fusing 2 2 di/dt Critical rate of rise of on-state current ...

Page 3

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Electrical Characteristics (T = 25°C, unless otherwise specified) J Symbol Test Conditions 12V Ω 3.3 kΩ DRM 100mA Gate Open T D DRM dv/ Gate Open T D DRM (dv/dt)c (di/dt)c = 8.6 A/ 15μ Static Characteristics Symbol 15A Device ...

Page 4

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Figure 3: Normalized DC Holding Current vs. Junction Temperature 4.0 3.0 2.0 1.0 0.0 -65 -40 -15 10 Junction Temperature (T Figure 5: Power Dissipation (Typical) vs. RMS On-State Current RMS On-State Current [I Figure 7: Maximum Allowable Case Temperature vs. On-State Current (16A devices) ...

Page 5

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Figure 9: On-State Current vs. On-State Voltage (Typical 25º 0.6 0.8 1.0 1.2 Positive or Negative Instantaneous On-State Voltage (v Figure 10: Surge Peak On-State Current vs. Number of Cycles 1000 100 Surge Current Duration - Full Cycles Soldering Parameters Reflow Condition ...

Page 6

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Physical Specifications 100% Matte Tin-plated Terminal Finish UL recognized epoxy meeting flammability Body Material classification 94V-0 Copper Alloy Terminal Material Design Considerations Careful selection of the correct device for the application’s operating parameters and environment will go a long way toward extending the operating life of the Thyristor ...

Page 7

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Dimensions — TO-220AB (L-Package) — Isolated Mounting Tab T MEASURING POINT MT1 MT2 GATE Dimensions — TO-263AB (N-Package) — MEASURING POINT MT2 GATE MT1 1168 2.16 .460 .085 7.01 7.01 .276 .276 16.89 .665 8 ...

Page 8

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs Product Selector Voltage Part Number 400V 600V 800V 1000V Qxx15L5 X X Qxx15R5 X X Qxx15N5 X X Qxx16LH2 X X Qxx16RH2 X X Qxx16NH2 X X Qxx16LH3 X X Qxx16RH3 X X Qxx16NH3 X X Qxx16LH4 X X Qxx16RH4 X X Qxx16NH4 X X Qxx16LH6 ...

Page 9

... Amp Standard & 16 Amp Alternistor (High Commutation) Triacs TO-263 Embossed Carrier Reel Pack (RP) Meets all EIA-481-2 Standards 0.945 (24.0) 0.512 (13.0) Arbor Part Numbering System DEVICE TYPE Q: Triac or Alternistor VOLTAGE RATING 40: 400V 60: 600V 80: 800V K0: 1000V CURRENT RATING 15: 15A 16: 16A Qxx15xx & Qxx16xHx Series ...

Related keywords