ACS120-7SH STMicroelectronics, ACS120-7SH Datasheet - Page 5

IC AC LINE SWITCH IPAK

ACS120-7SH

Manufacturer Part Number
ACS120-7SH
Description
IC AC LINE SWITCH IPAK
Manufacturer
STMicroelectronics
Series
ASD™r
Datasheet

Specifications of ACS120-7SH

Triac Type
Logic - Sensitive Gate
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
45mA
Voltage - Off State
700V
Current - Gate Trigger (igt) (max)
10mA
Current - Non Rep. Surge 50, 60hz (itsm)
20A, 11A
Current - On State (it (rms)) (max)
2A
Voltage - Gate Trigger (vgt) (max)
1V
Package / Case
TO-251-3 Long Leads, IPak, TO-251AB
Current - On State (it (rms) (max)
2A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Fig. A: Turn-off operation of the ACS120 switch
with an electro-valve: waveform of the pin OUT
current I
AC LINE TRANSIENT VOLTAGE RUGGEDNESS
The ACS120 switch is able to sustain safely the AC line transient voltages either by clamping the low en-
ergy spikes or by breaking over under high energy shocks, even with high turn-on current rises.
The test circuit of the figure C is representative of the final ACS application and is also used to stress the
ACS switch according to the IEC 61000-4-5 standard conditions. Thanks to the load, the ACS switch sus-
tains the voltage spikes up to 2 kV above the peak line voltage. It will break over safely even on resistive
load where the turn on current rise is high as shown on figure D. Such non repetitive test can be done 10
times on each AC line voltage polarity.
Fig. C: Overvoltage ruggedness test circuit
for resistive and inductive loads according to
IEC61000-4-5 standards.
R = 150 , L = 10µH, V
AC LINE & GENERATOR
SURGE VOLTAGE
OUT
and voltage V
PP
V
R
= 2kV.
AC
OUT
+ V
.
PP
L
D
COM
S
RG = 220
OUT
ON
ACSxx
G
Fig. B: ACS120 switch static characteristic.
Fig. D: Current and Voltage of the ACS120 dur-
ing IEC61000-4-5 standard test with R, L & V
I
H
I
OUT
ACS120-7SB/SFP/ST
V
CL
V
OUT
PP
5/11
.