W2E200-HK86-01 EBM-Papst Industries Inc, W2E200-HK86-01 Datasheet

FAN 225X80MM 115VAC 606CFM

W2E200-HK86-01

Manufacturer Part Number
W2E200-HK86-01
Description
FAN 225X80MM 115VAC 606CFM
Manufacturer
EBM-Papst Industries Inc
Series
W2E200r
Type
AC Fanr

Specifications of W2E200-HK86-01

Current Type
AC
Bearing Type
Ball
Fan Type
Tubeaxial
Size / Dimension
Square - 225mm L x 225mm H x 80mm W
Voltage Rating
115VAC
Power (watts)
80W
Rpm
2800 RPM
Noise
61 dB(A)
Static Pressure
0.482 in H2O (120.0 Pa)
Air Flow
606.0 CFM (17.16m³/min)
Termination
Terminal Block
Weight
4.4 lbs (2kg)
Termination Style
61 dB(A)
Product
Fans
External Height
225mm
External Width
225mm
External Depth
80mm
Supply Voltage
115VAC
Flow Rate
606CFM
Noise Rating
61dBA
Power Connection Type
Terminal
Bearings
Ball
Noise Level
59/61dB
Housing Material
Aluminum Die Cast
Power Rating
64/80W
Product Length (mm)
260mm
Product Height (mm)
80mm
Product Depth (mm)
260mm
Fan Rotation
Counter Clockwise
Brand/series
W2E200
Dimensions
8.86 x 3.15 "
Direction
Exhaust over Struts
Nominal Speed
2550 to 2800 RPM
Power, Rating
80 W
Size
8.86 x 3.15 (225 x 80) In. (mm)
Temperature, Operating, Maximum
+65 °C
Thickness
80 mm
Voltage, Rating
115 VAC
Flow Rate - Imperial
606CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
381-2281
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
74673 Mulfingen
Phone: +49 7938 81-0
Fax: +49 7938 81-110
www.ebmpapst.com
info1@de.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND NOTES
1.1 Levels of hazard warnings
1.2 Staff qualification
1.3 Basic safety rules
1.4 Electrical voltage
1.5 Safety and protective functions
1.6 Mechanical movement
1.7 Emission
1.8 Hot surface
1.9 Transport
1.10 Storage
1.11 Disposal
2. PROPER USE
3. TECHNICAL DATA
3.1 Graphic rendition of products
3.2 Nominal data
3.3 Technical description
3.4 Mounting data
3.5 Storage conditions
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.3 Connection via terminal strip
4.4 Connection diagram
4.5 Checking the connections
4.6 Switch on device
4.7 Switching off the device
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
5.1 Cleaning
5.2 Safety test
Item no.: 11016-5-9970 · Revision status: KM71618 · Print-out on 03/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page 1 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
W2E200-HK86-01
Operating instructions
1
1
1
1
1
2
2
2
2
2
2
2
3
4
4
5
5
5
5
6
6
6
6
7
8
8
8
8
9
9
1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
1.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
1.2 Staff qualification
Only specialised electrical personnel may install the device, perform the
test run and work on the electrical system.
Only trained and authorised specialist personnel are permitted to
transport, unpack, assemble, operate or maintain the device, or to use it
in any other manner.
1.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
Observe the following when working on the unit:
1.4 Electrical voltage
Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
Check the electrical equipment of the device at regular intervals.
Remove loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. Compliance with
the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Exercise extreme
caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Danger of injury
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.
Keep out of the danger zone of the device.
When working on the device, switch off the mains

Related parts for W2E200-HK86-01

W2E200-HK86-01 Summary of contents

Page 1

... W2E200-HK86-01 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 74673 Mulfingen Phone: +49 7938 81-0 Fax: +49 7938 81-110 www.ebmpapst.com info1@de.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND NOTES 1.1 Levels of hazard warnings 1.2 Staff qualification 1.3 Basic safety rules 1.4 Electrical voltage 1.5 Safety and protective functions 1 ...

Page 2

... W2E200-HK86-01 supply voltage and secure the latter from being switched on again. Wait until the device stops. 1.5 Safety and protective functions DANGER Missing safety device and non-functioning safety device If there is no safety device, you could be seriously injured, for example by reaching into the running device with your hands. ...

Page 3

... W2E200-HK86-01 2. PROPER USE The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur. ...

Page 4

... W2E200-HK86-01 3. TECHNICAL DATA 3.1 Graphic rendition of products All measures have the unit mm. 1 Direction of air flow "V" Item no.: 11016-5-9970 · Revision status: KM71618 · Print-out on 03/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com ...

Page 5

... W2E200-HK86-01 3.2 Nominal data Motor M2E068-BF Phase 1~ Nominal voltage [V] 115 Frequency [Hz] 50 Type of data definition rfa Valid for approval / CE standard Speed [min -1 ] 2550 Power input [W] 64 Current draw [A] 0.58 Motor capacitor [µF] 5 Capacitor voltage [VDB] 220 Capacitor standard P0 (CE) Max. back pressure [Pa] 100 Max ...

Page 6

... W2E200-HK86-01 4. CONNECTION AND START-UP 4.1 Connecting the mechanical system CAUTION Cutting and crushing hazard when removing the fan from the packaging Carefully lift the fan out of its packaging, only touching the housing. Make sure to avoid any shock. Wear safety shoes and cut-resistant safety gloves. ...

Page 7

... W2E200-HK86-01 4.4 Connection diagram U1 blue Z brown U2 black PE green/yellow Item no.: 11016-5-9970 · Revision status: KM71618 · Print-out on 03/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com ...

Page 8

... W2E200-HK86-01 4.5 Checking the connections Make sure that the power is off (all phases). Secure it from being switched on again. Check the correct fit of the connection lines. 4.6 Switch on device WARNING Hot motor housing Fire hazard Ensure that no combustible or flammable materials are located close to the fan. ...

Page 9

... W2E200-HK86-01 If you have any other problems, contact ebm-papst. 5.1 Cleaning NOTE Damage to the device during cleaning. Malfunction possible Do not clean the device using a water jet or high-pressure washer. Do not use any cleaners containing acids, bases or solvents. 5.2 Safety test What has to be ...

Related keywords