FAN 220 X 71MM 115VAC

R2E220-AA44-23

Manufacturer Part NumberR2E220-AA44-23
DescriptionFAN 220 X 71MM 115VAC
ManufacturerEBM-Papst Industries Inc
SeriesR2E220
TypeRound
R2E220-AA44-23 datasheets
 

Specifications of R2E220-AA44-23

Current TypeACBearing TypeBall
Termination Style74 dB(A)Noise74 dB(A)
Fan TypeMotorized ImpellersSize / DimensionRound - 220mm Dia x 71mm W
Voltage Rating115VACPower (watts)100W
Rpm2550 RPMAir Flow530.0 CFM (15.00m³/min)
Termination4 Wire LeadsWeight2.9 lbs (1.3kg)
Airflow530 CFMSpeed2550 RPM
Frame Dimensions (mm)220 mm x 63 mmPower Rating100 W
External Depth63mmExternal Diameter220mm
Supply Voltage115VACFlow Rate530CFM
Noise Rating74dBAPower Connection TypeLead Wires
Brand/seriesR2E220Capacitance10 μF
Diameter, Outer220 mmDimensions8.66"Dia.x2.8"W
Material, ImpellerPlastic PA 6.6Noise Level74 dBA
Power, Rating100 WStandardsUL Listed, CSA Certified, VDE Approval
Temperature, Ambient40 °C (Max.)Temperature, Operating, Maximum+40 °C
Voltage, Rating115 VACRecommended Inlet Ring9609-2-4013 (Sold Separately)
Diameter220mmFlow Rate - Imperial530CFM
Rohs CompliantYesLead Free Status / RoHS StatusLead free / RoHS Compliant
Static Pressure-Other names381-1110
R2E220AA4423
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
Page 1/9

Download datasheet (138Kb)Embed
Next
R2E220-AA44-23
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
74673 Mulfingen
Phone: +49 7938 81-0
Fax: +49 7938 81-110
www.ebmpapst.com
info1@de.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND NOTES
1.1 Levels of hazard warnings
1.2 Staff qualification
1.3 Basic safety rules
1.4 Electrical voltage
1.5 Safety and protective functions
1.6 Mechanical movement
1.7 Emission
1.8 Hot surface
1.9 Transport
1.10 Storage
1.11 Disposal
2. PROPER USE
3. TECHNICAL DATA
3.1 Graphic rendition of products
3.2 Nominal data
3.3 Technical description
3.4 Mounting data
3.5 Storage conditions
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.3 Connection of the cables
4.4 Connection diagram
4.5 Checking the connections
4.6 Switch on device
4.7 Switching off the device
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
5.1 Cleaning
5.2 Safety test
Item no.: 11014-5-9970 · Revision status: KM71618 · Print-out on 08/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page 1 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
Operating instructions
1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
1.1 Levels of hazard warnings
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
DANGER
1
Indicates an imminently hazardous situation which, if not
1
avoided, will result in death or serious injury. Compliance with
the measures is mandatory.
2
2
WARNING
Indicates a potentially hazardous situation which, if not avoided,
2
could result in death or serious injury. Exercise extreme
2
caution while working.
2
CAUTION
2
Indicates a potentially hazardous situation which, if not avoided,
2
may result in minor or moderate injury or damage of property.
NOTE
3
A potentially harmful situation can occur and, if not avoided, can
4
lead to property damage.
4
1.2 Staff qualification
5
Only specialised electrical personnel may install the device, perform the
5
test run and work on the electrical system.
5
Only trained and authorised specialist personnel are permitted to
transport, unpack, assemble, operate or maintain the device, or to use it
5
in any other manner.
6
1.3 Basic safety rules
6
Any safety hazards stemming from the device must be re-evaluated
6
once it is installed in the end device.
6
Observe the following when working on the unit:
7
Do not make any modifications, additions or conversions to the
8
device without the approval of ebm-papst.
8
1.4 Electrical voltage
8
Check the electrical equipment of the device at regular intervals.
8
Remove loose connections and defective cables immediately.
WARNING
9
Terminals and connections have voltage even with a
9
unit that is shut off
Electric shock
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Danger of injury
Keep out of the danger zone of the device.
When working on the device, switch off the mains

R2E220-AA44-23 Summary of contents

  • Page 1

    ... R2E220-AA44-23 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 74673 Mulfingen Phone: +49 7938 81-0 Fax: +49 7938 81-110 www.ebmpapst.com info1@de.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND NOTES 1.1 Levels of hazard warnings 1.2 Staff qualification 1.3 Basic safety rules 1.4 Electrical voltage 1.5 Safety and protective functions 1 ...

  • Page 2

    ... R2E220-AA44-23 supply voltage and secure the latter from being switched on again. Wait until the device stops. 1.5 Safety and protective functions DANGER Missing safety device and non-functioning safety device If there is no safety device, you could be seriously injured, for example by reaching into the running device with your hands. ...

  • Page 3

    ... R2E220-AA44-23 2. PROPER USE The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur. ...

  • Page 4

    ... R2E220-AA44-23 3. TECHNICAL DATA 3.1 Graphic rendition of products All measures have the unit mm. 1 Connection line PVC 4G 0.5 mm², 4x brass lead tips crimped 2 Accessory part: Inlet nozzle 09609-2-4013, not included in the standard scope of delivery 3 Depth of screw max Item no.: 11014-5-9970 · Revision status: KM71618 · Print-out on 08/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page ebm-papst Mulfingen GmbH & ...

  • Page 5

    ... R2E220-AA44-23 3.2 Nominal data Motor M2E068-BF Phase 1~ Nominal voltage [V] 115 Frequency [Hz] 50 Type of data definition rfa Valid for approval / CE standard Speed [min -1 ] 2550 Power input [W] 75 Current draw [A] 0.67 Motor capacitor [µF] 10 Capacitor voltage [VDB] 220 Min. back pressure [Pa] 0 Max. ambient - temperature [° ...

  • Page 6

    ... R2E220-AA44-23 4. CONNECTION AND START-UP 4.1 Connecting the mechanical system CAUTION Cutting and crushing hazard when removing the fan from the packaging Carefully seize the impeller to lift the device out of its packaging. Make sure to avoid any shock. Wear safety shoes and cut-resistant safety gloves. ...

  • Page 7

    ... R2E220-AA44-23 4.4 Connection diagram U1 blue Z brown U2 black PE green/yellow Item no.: 11014-5-9970 · Revision status: KM71618 · Print-out on 08/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com ...

  • Page 8

    ... R2E220-AA44-23 4.5 Checking the connections Make sure that the power is off (all phases). Secure it from being switched on again. Check the correct fit of the connection lines. 4.6 Switch on device WARNING Hot motor housing Fire hazard Ensure that no combustible or flammable materials are located close to the fan. ...

  • Page 9

    ... R2E220-AA44-23 If you have any other problems, contact ebm-papst. 5.1 Cleaning NOTE Damage to the device during cleaning. Malfunction possible Do not clean the device using a water jet or high-pressure washer. Do not use any cleaners containing acids, bases or solvents. 5.2 Safety test What has to be ...