R2E220-AA44-23 EBM-Papst Industries Inc, R2E220-AA44-23 Datasheet - Page 6

FAN 220 X 71MM 115VAC

R2E220-AA44-23

Manufacturer Part Number
R2E220-AA44-23
Description
FAN 220 X 71MM 115VAC
Manufacturer
EBM-Papst Industries Inc
Series
R2E220r
Type
Roundr

Specifications of R2E220-AA44-23

Current Type
AC
Bearing Type
Ball
Termination Style
74 dB(A)
Noise
74 dB(A)
Fan Type
Motorized Impellers
Size / Dimension
Round - 220mm Dia x 71mm W
Voltage Rating
115VAC
Power (watts)
100W
Rpm
2550 RPM
Air Flow
530.0 CFM (15.00m³/min)
Termination
4 Wire Leads
Weight
2.9 lbs (1.3kg)
Airflow
530 CFM
Speed
2550 RPM
Frame Dimensions (mm)
220 mm x 63 mm
Power Rating
100 W
External Depth
63mm
External Diameter
220mm
Supply Voltage
115VAC
Flow Rate
530CFM
Noise Rating
74dBA
Power Connection Type
Lead Wires
Brand/series
R2E220
Capacitance
10 μF
Diameter, Outer
220 mm
Dimensions
8.66"Dia.x2.8"W
Material, Impeller
Plastic PA 6.6
Noise Level
74 dBA
Power, Rating
100 W
Standards
UL Listed, CSA Certified, VDE Approval
Temperature, Ambient
40 °C (Max.)
Temperature, Operating, Maximum
+40 °C
Voltage, Rating
115 VAC
Recommended Inlet Ring
9609-2-4013 (Sold Separately)
Diameter
220mm
Flow Rate - Imperial
530CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
381-1110
R2E220AA4423
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.2.1 Prerequisites
4.2.2 Voltage control
Item no.: 11014-5-9970 · Revision status: KM71618 · Print-out on 08/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page 6 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
R2E220-AA44-23
Install the device according to your application.
Check whether the data on the type plate agree with the connection
data and the data of the operating capacitor.
Before connecting the device, ensure that the supply voltage matches
the operating voltage of the device.
Only use cables designed for current according to the type plate.
CAUTION
Cutting and crushing hazard when removing the fan
from the packaging
DANGER
Electric voltage on the device
Electric shock
CAUTION
Electrical voltage
The fan is a built-in component and features no electrically
isolating switch.
NOTE
Water penetration into leads or wires
Water enters at the cable end on the customers side and can
damage the device.
Connect the device only to circuits that can be switched off
using an all-pole disconnecting switch.
With open loop speed control using transformers or electronic
voltage regulators (e.g. phase angle control), excessive current
may occur.
In addition, noises can occur with phase angle control
depending on the mounting situation.
Carefully seize the impeller to lift the device out of its
packaging. Make sure to avoid any shock.
Wear safety shoes and cut-resistant safety gloves.
Always install a protective earth.
Check the protective earth.
Only connect the fan to circuits that can be switched off with
an all-pole separating switch.
When working on the fan, you must switch off the
installation/machine in which the fan is installed and secure it
from being switched on again.
Make sure that the cable end is connected in a dry
environment.
Operating instructions
4.2.3 Frequency inverter
4.3 Connection of the cables
External leads are brought out of device.
Connect the lines according to your application. When doing so,
observe chapter 4.4 Connection diagram.
Fit sinusoidal filters that work on all poles (live-live and live-
earth) between the frequency inverter and the motor for
operation with frequency inverters.
Depending on how the device is installed, noises may occur.