88 865 105 Crouzet USA, 88 865 105 Datasheet - Page 6

TIMER, MULTIFUNCTION

88 865 105

Manufacturer Part Number
88 865 105
Description
TIMER, MULTIFUNCTION
Manufacturer
Crouzet USA
Datasheet

Specifications of 88 865 105

Contact Configuration
SPCO
Nom Input Voltage
240VAC
Delay Time Range
0.1s To 100h
Relay Mounting
DIN Rail
Svhc
No SVHC (18-Jun-2010)
Adjustment Type
Screwdriver Slot
Coil Voltage Vdc Nom
24V
Contact
RoHS Compliant
Contact Current Ac Max
8A
Rohs Compliant
Yes
Timing range:
Digits:
Mounting:
Operating temperature:
Storage temperature:
Supply tolerance:
Approvals:
Weight:
Repetition accuracy:
Relay output:
Contact rating (resistive):
Max breaking current:
Max breaking voltage:
Electrical life:
Mechanical life:
M812
M814
~ +
~
Type
M812/24
M812/110
M812/230
M814LV
M814HV
G814LV
G814HV
G815LV
G815HV/110
G815HV
AZ 58
AZ 511
4821
PRE48
~
~
+
-
2
(1) Other loads may be connected in parallel
U
U
8 : 12 Vdc
24 Vac/dc
Start
CONNECTIONS
(1)
Function
Delay on
Delay on
Delay on
Multifunction
Multifunction
Multifunction
Multifunction
Multifunction
Multifunction
Multifunction
Screw terminal socket, 8 pin
Screw terminal socket, 11 pin
Transparent soft cover to offer splash protection
Transparent hard cover to offer splash protection
G815
G814
2
-
~
2
~
+
~
~ +
• •
11 :12 Vdc
U
7 :
U
0.1 seconds to 9999 hours
4 (8mm high)
Panel mounting by clip
-10 deg C to +60 deg C
-30 deg C to +70 deg C
-15/+10%
UL/CSA
‘814’ - 100g
‘812 & 815’ - 140g
+/-0.03% +/-20ms
3
3
4
4
24 Vac/dc
Reset
24 Vac/dc
2
2
5
5
2 timed changeover contacts
Start
1
1
6 7
6 7
11
11
10
10
8
8
9
9
12 Vdc
1200VA - 120W
5A ac/dc
(1)
(1)
812
FRONT PANEL DIGITAL 48 X 48mm
• 4 digit LCD display
• Up or down timing mode
• Multi voltage (except M812)
• 1 or 2 pole changeover relay
• Protection class IP65
• Visual indication of relay status and power on
GENERAL SPECIFICATIONS
Function Code
A2
A2
A2
A,B,C,D,Di,H
A,B,C,D,Di,H
A,B,C,D,Di,H
A,B,C,D,Di,H
A,A2,AM,AMt
A,A2,AM,AMt
A,A2,AM,AMt
Function AM
Delay on energisation
Memory during timing.
Auto reset
Function AMt
Delay on energisation
Memory during and after
timing. Reset
ORDERING GUIDE
OUTPUT RELAY
100 000 operations at max contact rating
FUNCTIONS
8-9-11
8-9-11
1-3-4
1-3-4
2-10
2-10
2-5
2-5
1 timed changeover contact
67
t1
t1
5,000,000 operations
t2
t2
250Vac - 30Vdc
Display accuracy:
Minimum pulse time:
(for ‘AM’, ‘AMt’, ‘B’
and ‘C’ functions)
Maximum reset time after
power down:
Power consumption (max):
t
T
T
814
T=t1+t2
T=t1+t2
Voltage
24Vac/dc
110Vac
220-240Vac
12Vdc + 24-48 Vac/dc
24Vac/dc + 110-240 Vac
12Vdc + 24-48 Vac/dc
24Vac/dc + 110-240 Vac
12Vdc + 42-48 Vac/dc
24Vac/dc + 110 Vac
24Vac/dc + 220-240Vac
2000VA - 190W
8A ac/dc
5,5
TIMER 814 / 815
Panel cut-out : 45 square
(or 1 timed + 1 instantaneous)
2 timed changeover contacts
+/-0.03% +/-20ms
50ms
during T on 50ms
during T off 50ms
12Vdc 0.5W
24Vdc - 0.5W
24Vac - 1.0VA
110Vac - 3.5VA
230Vac - 11.0VA
70,4
Panel thickness 1 to 3.5 mm
64
DIMENSIONS
815
Clip for panel-mounting
Positioning screw
± 0.3
14,5
0
TIMERS
Part number
88 857 409
88 857 406
88 857 400
88 857 003
88 857 005
88 857 103
88 857 105
88 857 302
88 857 307
88 857 301
VALID
48
MODE
AZ 511
PRE48
AZ 58
4821

Related parts for 88 865 105