H3DK-M1 AC/DC24-240 Omron, H3DK-M1 AC/DC24-240 Datasheet

no-image

H3DK-M1 AC/DC24-240

Manufacturer Part Number
H3DK-M1 AC/DC24-240
Description
TIMER, MULTIFUNCTION, 5A, 24-240AC/DC
Manufacturer
Omron
Datasheet

Specifications of H3DK-M1 AC/DC24-240

Contact Configuration
SPDT
Delay Time Range
0.1s To 1200h
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Adjustment Type
Screwdriver Slot
Contact Current Ac Max
5A
Contact Current Dc
RoHS Compliant
Supply Voltage Range
24VAC To 240VAC / 24VDC To 240VDC
Time Range
0.1sec To 1200hr
Rohs Compliant
Yes
DIN Track-mounted, 22.5-mm-width
Standard Timer Series
*1. Except for the H3DK-H.
*2. Certification for the H3DK-GE is scheduled to be obtained in the near future.
*3. Except for the H3DK-GE.
Model Number Structure
■ The Entire H3DK Series
■ Model Number Legend
H3DK-@@@@
1. Type
• A wide AC/DC power supply range (24 to 240 VAC/DC).
• All sub-series include models with 12-VDC power supply.
• G-type Models (H3DK-G) now include model with 240 to 440-
• UL
• EMC (EN 61812-1) compliance for application in heavy industri-
• Finger-safe terminal block and captive screws according to EN
New Product News
Symbol
Solid-state Timers
H3DK
VAC power supply.
CE Marking.
al, residential, commercial, or light industrial environments.
50274.
H3DK-M/-S Multi-range,
Multi-mode Timers
■ Eight-mode Timer
■ Four-mode Timer
M
S
G
H
F
H3DK-M1/M2
● Operating Modes
A: ON Delay
B: Flicker OFF Start
B2: Flicker ON Start
C: Signal ON/OFF Delay
D: Signal OFF Delay
E: Interval
G: Signal ON/OFF Delay
J: One-shot Output
H3DK-S1/S2
● Operating Modes
A: ON Delay
B2: Flicker ON Start
E: Interval
J: One-shot Output
*3
, CSA, and CCC
Eight-mode Timer
Four-mode Timer
Twin Timer
Star-delta Timer
Power OFF-delay Timer
1 2 3 4
Meaning
Page 2
*2
certification and EN 61812-1 compliance.
(Not all models that can be represented with the model number legend can necessarily be produced.)
2. Control Output
* M- and S-type models only.
Symbol
H3DK-F
Twin Timers
1
2
● Operating Modes
Flicker-OFF Start/
Flicker-ON Start
Meaning
SPDT
DPDT
Page 11
H3DK Series
*1
*1
3. Supply Voltage
* G-type models only.
Symbol
Blank
H3DK-G
Star-delta Timers
A
B
C
D
E
● Operating Modes
Star-delta Timer
24 to 240 VAC/DC
12 VDC
24 to 48 VAC/DC
100 to 120 VAC
200 to 240 VAC
240 to 440 VAC *
Meaning
Page 15
4. Time Ranges (H-type
Symbol
Models Only)
S
L
H3DK-H Power
OFF-delay Timers
● Operating Modes
Power OFF-delay
Timer
0.1 to 1.2 s or 1 to 12 s
1 to 12 s or 10 to 120 s
Meaning
Page 21
LR
1

Related parts for H3DK-M1 AC/DC24-240

H3DK-M1 AC/DC24-240 Summary of contents

Page 1

... Finger-safe terminal block and captive screws according to EN 50274. *1. Except for the H3DK-H. *2. Certification for the H3DK-GE is scheduled to be obtained in the near future. *3. Except for the H3DK-GE. Model Number Structure ■ The Entire H3DK Series ...

Page 2

... The time-limit DPDT output contacts can be changed to time-limit SPDT and instantaneous SPDT output contacts using a switch. • Sequence checks are easily performed by setting an instanta- neous output to 0. • Start signal control for the H3DK-M. Ordering Information ■ List of Models Supply voltage ...

Page 3

... Refer to DC Power Consumptions (Reference Infor- *4 mation) on page 27 for DC power consumptions. *4 *5. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capac- ity (Reference Values) on the next page. *6. ...

Page 4

... A at 250 VAC, resistive load at 360 operations/h) Degree of protection IP30 (Terminal block: IP20) Weight Approx. 120 g * With the H3DK-M@, if the voltage exceeds 26.4 VAC/DC in mode the OFF trigger signal char- acteristics are as follows: Accuracy of operating time: ±1% ±50 ms max. +100 ms Setting error: ±10% max. − ...

Page 5

... ROM Power supply circuit One-chip microcomputer Time specification Operating mode switches switch RAM Clock Output circuit Input circuit Indicator circuit Power Output indicator indicator Time specification Operating switches mode switch RAM Clock Output circuit Indicator circuit Output Power indicator indicator H3DK-M/H3DK-S 5 ...

Page 6

... Note 2: *The relay R2 can be set to either instantaneous or time-limit contacts using the switch on the front of the Timer. Note 3: The power supply terminals do not have polarity. (DIN notation) (DIN notation ■ Input Connections The start input of the H3DK-M1/- voltage input. PNP Transistor Input NPN Transistor Input Sensor 24 VDC Timer Sensor (sensor power supply) A1 (+) (+) 24 24 ...

Page 7

... ON.) Operating mode switch* *If the switch is left between settings, proper operation may not be possible. Make sure that the switch is set properly. Note: The default settings are for 0 mode A. H3DK-M/H3DK-S 2 Note 1. Use solid wire (2.5 mm max.) or fer- rules with insulative sleeves to connect to the terminals ...

Page 8

... Do not set it midway between two positions. Malfunction could result from an improper setting. Setting the Operating Mode ● Setting the Operating Mode The H3DK-M can be set to any of eight operating modes. The H3DK-S can be set to any of four operating modes. Turn the operating mode switch with a flat- blade or Phillips screwdriver. The H3DK- M can be set to any of eight modes ...

Page 9

... Timing Charts • There is no start input with the H3DK-S. Timer operation starts when the power is turned ON. • There is no instantaneous output with the H3DK-@ Delay t Power (A1 and A2) Start (B1 and A1) Time-limit contacts and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) ...

Page 10

... H3DK-M/H3DK-S D: Signal OFF delay t Power (A1 and A2) Start (B1 and A1) Time-limit contacts and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) Instantaneous contacts: NC (21 and 22) Instantaneous contacts: NO (21 and 24) Power indicator E: Interval t Power (A1 and A2) Start (B1 and A1) Time-limit contacts and 16 (25 and 26) ...

Page 11

... Contact output (SPDT 250 VAC with resistive load (cosφ Control output −20 to 55°C (with no icing) Ambient operating temperature −40 to 70°C (with no icing) Storage temperature Ambient operating humidity 25% to 85% H3DK-F Model H3DK-F Model H3DK-FA Specification Terminal block Output type Mounting method 6 terminals Relay, SPDT DIN Track mounting ...

Page 12

... DC ripple: 20% max. *3. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *4. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) on the next page. ...

Page 13

... RAM Clock One-chip microcomputer Output circuit Bottom View User label attachment location ON time setting dial (Sets the ON time.) Terminal Block (See notes 1 and 2.) OFF time setting dial (Sets the OFF time.) H3DK-F ■ Terminal Arrangement H3DK (DIN notation Note: The power supply terminals do not have po- larity ...

Page 14

... H3DK-F Dimensions ■ Timers H3DK-F ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation Setting the Time Ranges ● Setting the Time Ranges Use the ON time range switch to set the ON time range and the OFF time range switch to set the OFF time range ...

Page 15

... Spacer --- ■ Model Structure Model Terminal block Operating/resetting method Time-limit operation/self- H3DK-G 9 terminals *1. Except for the H3DK-GE. Specifications ■ Time Ranges Time range setting t1x1 Star set time (t1) range Star-Delta transfer time (t2) Select from 0.05, 0.1, 0.25, or 0.5 s. ■ Ratings • ...

Page 16

... VDC: 0.15 A max. with resistive load, 125 VDC: 0.1 A with L ms. Minimum load VDC (P level, reference value) *6. For the H3DK-GE, approx inrush current will flow when the power supply is turned ON. When selecting the device connected to the Timer, allow leeway in the current ratings. ...

Page 17

... Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: Burst Immunity: Surge Immunity: *1. This standard is not applicable to the H3DK-GE. *2. This standard is not applicable if the output is used with a rating that exceeds 250 VAC. ■ I/O Input The star output is turned OFF when the dial set value is reached and the ...

Page 18

... H3DK-G Nomenclature H3DK-G Front View Star operation indicator (green) Delta operation indicator (orange) Star-delta transfer time switch H3DK-GE Front View Star operation indicator (green) Delta operation indicator (orange) Star-delta transfer time switch 18 Bottom View User label attachment location Terminal block (See notes 1 and 2.) Main dial (Sets the star time ...

Page 19

... Dimensions ■ Timers H3DK-G H3DK-GE ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. 100 88.2 22.5 69.1 79 65.6 52 102 88.2 26 69.1 22.5 H3DK-G (Unit: mm ...

Page 20

... H3DK-G Operating Procedures ■ Basic Operation Setting the Time Ranges ● Setting the Delta Time Range and the Star-delta Transfer Time (t2) Star Time (t1) Range Set the star-delta transfer time. For × s), use side (A) (labeled “t1×1”). For ×10 (10 to 120 s), use side (B) (labeled “t10×1”). ...

Page 21

... VAC, 50/60 Hz • 200 to 240 VAC, 50/60 Hz • VAC/DC, 50/ H3DK-H S Series L Series (time range: 1.0 to 120 s) H3DK-HCS H3DK-HCL H3DK-HDS H3DK-HDL H3DK-HBS H3DK-HBL Model PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Safety standards Accessories cURus (UL 508 CSA C22.2 No. 14) ...

Page 22

... DC ripple: 20% max. (A single-phase, full-wave rectifying power supply can be connected.) *2. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *3. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) on the next page. ...

Page 23

... Power indicator (green) (Lit while the power is ON.) Time specification switches Counting circuit Output circuit Bottom View User label attachment location Terminal block (See notes 1 and 2.) Main dial (for setting the time) H3DK-H ■ Terminal Arrangement H3DK (DIN notation Note 1: The above figure shows the terminal ar- rangement for 48-VAC/DC model ...

Page 24

... H3DK-H Dimensions ■ Timers H3DK-H ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation Setting the Time Ranges ● Setting the Time Ranges The scale multiplier can be changed with the timer range switch. It can be changed between ×0.1 s and ×1 s for an S-series Timer and between × ...

Page 25

... Do not disassemble, mod- ify, or repair the Timer or touch any internal parts. Precautions for Safe Use • Use ferrules to wire the H3DK. If stranded wires are used, wire scraps may enter the Timer, possibly shorting the circuits. • Rapid changes in temperature or high humidity may cause condensation in Timer circuits, possibly resulting in malfunc- tion or damage to components ...

Page 26

... H3DK Start input A2 Circuit Isolation transformer is required. • The H3DK-H has a large inrush current. Provide sufficient power supply capacity. If the power supply capacity is too small, there may be delays in turning ON the output. 26 ● Relationship between Input and Power Supply Cir- cuits (H3DK-M1/-M2) • ...

Page 27

... If there is any residual voltage due to current leakage, connect a bleeder resistor between the power supply terminals. ● Operating Frequency • The H3DK-H may malfunction used as shown below. Do not use the H3DK-H in these ways. Timer Repeatedly Times Out in Cycles Less ...

Page 28

... H3DK Track Mounting Products (Sold Separately) DIN Track PFP-100N PFP-50N DIN Track PFP-100N2 End Plate PFP-M Spacer PFP-S Note 1: Order the above products in multiples of 10. Note 2: The Tracks conform to DIN standards 1,000 (500)* 4 1,000 10 6.2 1.8 M4x8 panhead 1 screw 50 35.5 35.3 1 ...

Page 29

...

Page 30

...

Page 31

...

Page 32

... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...

Related keywords