NLP65-7612J ARTESYN, NLP65-7612J Datasheet

no-image

NLP65-7612J

Manufacturer Part Number
NLP65-7612J
Description
AC/DC Power Supply Single-OUT 12V 5.4A 75W 8-Pin
Manufacturer
ARTESYN
Datasheet

Specifications of NLP65-7612J

Input Voltage
120 to 370 V
Output Voltage
12 V
Maximum Current Rating
1.4(rms) A
Maximum Output Current
5.4 A
Number Of Outputs
1
Maximum Output Power
75 W
Efficiency
72(Typ) %
Input Frequency
47 to 63 Hz
Operating Temperature
0 to 70 °C
Safety
File No. 1040100-3336-0096
File No. LR41062C
Certification 60950
*NLP65-76xx version only
NLP65 Series
Single, dual,
and triple output
Special Features
• Universal Input
• 3” x 5” footprint
• Low profile fits 1U applications
• EN61000-3-2 compliance
• Overvoltage and short circuit
• 65 W with free air convection
• EN55022, EN55011 conducted
• EN61000-4-2,-3,-4, -5, -6
• RoHS compliant
• LPX80 enclosure kit available
• 2 year warranty
Total Power:
Input Voltage: 85 - 264 Vac
# of Outputs:
VDE0805/EN60950/IEC950
License No. 114404
UL1950 File No. E136005
CSA C22.2 No. 950
China Compulsory
option (HCC)
protection
cooling
emissions level B
immunity compliant
65 - 75W
120 - 370 Vdc*
Single, dual,
triple
Input
Output
Electrical Specifications
Input voltage range:
Input frequency range:
Input current:
(cold start)
Safety ground
leakage current:
Input current:
Input fuse:
Total regulation:
(line and load)
Rise time:
Transient response:
Temperature coefficient:
Overvoltage protection:
Short circuit protection:
Minimum output current:
Universal input
(see Note 2)
NLP65-76xx version only
120 Vac
230 Vac
120 Vac, 60 Hz
230 Vac, 50 Hz
120 Vac, with PFC
230 Vac, with PFC
120 Vac, without PFC
230 Vac, without PFC
UL/IEC127
Main output
Auxiliary outputs
At turn-on
Main output
25% step
at 0.1 A/µs
Main outputs
Cyclic operation
Single and multiple
85-264 Vac
120-370 Vdc
47-63 Hz
17 A max.
32 A max
0.7 mA
1.4 mA
1.4 mA
0.51 A rms
1.40 A rms
0.80 A rms
S3.15 A, 250 Vac In live and neutral
±2.0%
±5.0%
1.0 s, max
5.0% or 250 mV
max. dev., 1ms max.
recovery to 1%
±0.02%/°C
125%, ±10%
Continuous
(See Note 6)
Embedded Power for
Business-Critical Continuity
Rev.12.12.08_102
NLP65 Series
1 of 4

Related parts for NLP65-7612J

NLP65-7612J Summary of contents

Page 1

... NLP65 Series Single, dual, and triple output Total Power 75W Input Voltage 264 Vac 120 - 370 Vdc Outputs: Single, dual, triple Special Features • Universal Input • 3” x 5” footprint • Low profile fits 1U applications • EN61000-3-2 compliance option (HCC) • Overvoltage and short circuit protection • with free air convection cooling • ...

Page 2

... Output Power (Watts) 75W -40 °C to +85 °C 20 CFM FORCED AIR COOLING 65W Derate to 50% load See table 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70° 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV Rev.12.12.08_102 NLP65 Series NATURAL 38W CONVECTION 32W COOLING ...

Page 3

... NLP65-7629J 3 A 150 mV ±5. ±2.0% NLP65-7605J 6.5 A 120 mV ±2.0% NLP65-7612J 5.3 A 150 mV ±2.0% NLP65-7615J 3.5 A 240 mV ±2.0% NLP65-7624J 11 Conducted emissions testing were performed using the standard EN55022 set- up with a stand alone NLP65 unit placed on a grounded metal plate with a line choke on the AC input and ground wires (i.e. the wires are looped through an EMI suppression toroid). For system compliance it is usually necessary to install an ‘off-the-shelf’ AC inlet with an integral line filter in the system chassis or to install a line choke on the input wires as close as possible to AC entry point of the system chasssis ...

Page 4

... Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. Rev.12.12.08_102 NLP65 Series ...