FN2010-1-06 Schaffner EMC Inc, FN2010-1-06 Datasheet

FILTER 1-PHASE GENERAL EMI 1A

FN2010-1-06

Manufacturer Part Number
FN2010-1-06
Description
FILTER 1-PHASE GENERAL EMI 1A
Manufacturer
Schaffner EMC Inc
Series
FN 2010r
Type
Filterr
Datasheet

Specifications of FN2010-1-06

Termination Style
Fast-On
Filter Type
Power Line
Voltage - Rated
250V
Current
1A
Inductance
12mH
Mounting Type
Chassis Mount
Voltage Rating
250 VAC
Current Rating
1 A
Mounting Style
Chassis
Filtered
Yes
Frequency
DC to 400 Hz
Leakage Current
0.4 mA
Product
Power Line Filters
Type Of Inlet
Power Line
Brand/series
FN 2010 Series
Current, Leakage
0.74 mA
Current, Rating
1 A
Dimensions
24.3 H × 35 W × 64 L mm
Frequency, Operating
DC to 400 Hz
Hipot Rating, Line To Ground
2000
Hipot Rating, Line To Line
760
Phase
1
Primary Type
AC, General Purpose
Resistance
1 Megaohms
Schaffner Part Number
291-597
Voltage, Operating
250 VAC
Voltage, Rating
250 VAC
Wire Size
20 AWG
Leakage Current Max
740µA
Capacitance
0.1µF
Inductance Min
12mH
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
291-597
817-1240
FN2010 - 1 -06
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
Temperature range (operation and storage):
Flammability corresponding to:
Design corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
Features and benefits
General purpose EMI fi lter
FN 2010 filters are designed for easy and
fast chassis mounting.
FN 2010 filters are also available as B
versions without Y-capacitors for medical
applications as well as A version with low
capacitance for safety critical applications
with necessity for low leakage currents.
All filters provide a general purpose
conducted attenuation performance, based
on chokes with high saturation resistance
and excellent thermal behavior.
250VAC, 50/60Hz
dc to 400Hz
1 to 60A @ 40°C max.
P –> E 2000VAC for 2 sec
P –> E 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec (1 to 20A types)
P –> N 1100VDC for 2 sec (30 and 60A types)
-25°C to +100°C (25/100/21)
UL 94V-2 or better
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
1,250,000 hours
3,200,000 hours (B types)
Rated currents from 1 to 60A
General purpose filtering performance
Optional medical versions (B type)
Optional safety versions (A type)
FN 2010 filters can be used to cover a
broad range of usage and they offer a good
size/amperage ratio.
FN 2010 filters are also available as two-
stage filters (FN 2060, FN 2070 series) for
more noisy environment.
Various terminal options allow you to
select the desired connection style.
1-phase fi lters
FN 2010
Approvals
Typical electrical schematic
P
N
E
Typical applications
Line
Electrical and electronic equipment
Consumer goods
Household equipment
Medical equipment
Office automation equipment
Datacom equipment
Cx
R
L
Cy
Cy
Load
P‘
N‘

Related parts for FN2010-1-06

FN2010-1-06 Summary of contents

Page 1

... UL 94V-2 or better UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 1,250,000 hours 3,200,000 hours (B types) FN 2010 filters can be used to cover a ■ broad range of usage and they offer a good size/amperage ratio. FN 2010 filters are also available as two- ■ ...

Page 2

Components > FN 2010 Filter selection table Filter* Rated current Leakage current** @ 40°C (25°C) @ 230VAC/50Hz [A] FN 2010-1-.. 1 (1.15) FN 2010-3-.. 3 (3.45) FN 2010-6-.. 6 (6.9) FN 2010-10-.. 10 (11.5) FN 2010-12-.. 12 (13.8) FN ...

Page 3

Components > FN 2010 Mechanical data Connection style -06 12A types Connection style -07 12A types (same dimensions as style -06 GNYE BU BU Connection ...

Page 4

Components > FN 2010 Dimensions 24.3 24.3 D 43.5 43.5 E 32.5 32 9.3 9.3 I 15.3 15.3 J 21.8 21.8 K 5.3 ...

Related keywords