5962-8961403MXA E2V, 5962-8961403MXA Datasheet - Page 13

no-image

5962-8961403MXA

Manufacturer Part Number
5962-8961403MXA
Description
Manufacturer
E2V
Datasheet

Specifications of 5962-8961403MXA

Lead Free Status / RoHS Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8961403MXA
Quantity:
871
DSCC FORM 2234
APR 97
MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan
shall not affect the form, fit, or function as described herein. For device class M, sampling and inspection procedures shall be
in accordance with MIL-PRF-38535, appendix A.
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for
groups A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified herein. Quality conformance inspection for
device class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed
for device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections
(see 4.4.1 through 4.4.4).
4. QUALITY ASSURANCE PROVISIONS
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted
4.2.2 Additional criteria for device classes Q and V.
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
4.2.1 Additional criteria for device class M.
4.4.1 Group A inspection.
a.
b.
a.
b.
c.
a.
b.
c.
d.
e.
DEFENSE SUPPLY CENTER COLUMBUS
Tests shall be as specified in table IIA herein.
Subgroups 5 and 6 of Table IA of method 5005 of MIL-STD-883 shall be omitted.
The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1015 of MIL-STD-883.
Interim and final electrical test parameters shall be as specified in table IIA herein.
Additional screening for device class V beyond the requirements of device class Q shall be as specified in
MIL-PRF-38535, appendix B and as detailed in table IIB herein.
Delete the sequence specified as initial (preburn-in) electrical parameters through interim (postburn-in) electrical
parameters of method 5004 and substitute lines 1 through 6 of table IIA herein.
Prior to burn-in, the devices shall be programmed (see 4.6 herein) with a checkerboard pattern or equivalent
(manufacturers at their option may employ an equivalent pattern provided it is a topologically true alternating bit
pattern). The pattern shall be read before and after burn-in. Devices having bits not in the proper state after burn-in
shall constitute a device failure and shall be included in the PDA calculation and shall be removed from the lot.
The test circuit shall be maintained by the manufacturer under document revision level control and shall be made
available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases,
and power dissipation, as applicable, in accordance with the intent specified in test method 1015.
(1)
Interim and final electrical parameters shall be as specified in table IIA herein.
After the completion of all screening, the device shall be erased and verified prior to delivery.
MICROCIRCUIT DRAWING
COLUMBUS, OHIO 43216-5000
Dynamic burn-in (method 1015 of MIL-STD-883, test condition D) using the circuit referenced (see 4.2.1c
herein).
STANDARD
SIZE
A
REVISION LEVEL
F
SHEET
5962-89614
13

Related parts for 5962-8961403MXA