ISP1760ET,557

Manufacturer Part NumberISP1760ET,557
ManufacturerNXP Semiconductors
ISP1760ET,557 datasheet
 


Specifications of ISP1760ET,557

Package TypeTFBGAPin Count128
Lead Free Status / RoHS StatusCompliant  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
Page 81
82
Page 82
83
Page 83
84
Page 84
85
Page 85
86
Page 86
87
Page 87
88
Page 88
89
Page 89
90
Page 90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
Page 81/111

Download datasheet (570Kb)Embed
PrevNext
NXP Semiconductors
Table 78.
Start and complete split for interrupt: bit description
Bit
Symbol
Access
DW7
63 to 40
reserved
-
39 to 32
INT_IN_7[7:0]
HW — writes
DW6
31 to 24
INT_IN_6[7:0]
HW — writes
23 to 16
INT_IN_5[7:0]
HW — writes
15 to 8
INT_IN_4[7:0]
HW — writes
7 to 0
INT_IN_3[7:0]
HW — writes
DW5
63 to 56
INT_IN_2[7:0]
HW — writes
55 to 48
INT_IN_1[7:0]
HW — writes
47 to 40
INT_IN_0[7:0]
HW — writes
39 to 32
SCS[7:0]
SW — writes
(0
HW — writes
(1
After
processing
DW4
31 to 29
Status7[2:0]
HW — writes
28 to 26
Status6[2:0]
HW — writes
25 to 23
Status5[2:0]
HW — writes
22 to 20
Status4[2:0]
HW — writes
19 to 17
Status3[2:0]
HW — writes
16 to 14
Status2[2:0]
HW — writes
13 to 11
Status1[2:0]
HW — writes
ISP1760_4
Product data sheet
Value
Description
-
-
-
Bytes received during SOF7, if SA[7] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
-
Bytes received during SOF6, if SA[6] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
-
Bytes received during SOF5, if SA[5] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
-
Bytes received during SOF4, if SA[4] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
-
Bytes received during SOF3, if SA[3] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
-
Bytes received during SOF2 (bits 7 to 0), if SA[2] is set to 1 and
frame number is correct. The new value continuously overwrites
the old value.
-
Bytes received during SOF1, if SA[1] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
-
Bytes received during SOF0 if SA[0] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
-
All bits can be set to one for every transfer. It specifies which SOF
1)
the complete split needs to be sent. Valid only for IN. Start split and
complete split active bits, SA = 0000 0001, SCS = 0000 0100,
will cause SS to execute in Frame0 and CS in Frame2.
0)
-
Interrupt IN or OUT status of SOF7
-
Interrupt IN or OUT status of SOF6
-
Interrupt IN or OUT status of SOF5
-
Interrupt IN or OUT status of SOF4
-
Interrupt IN or OUT status of SOF3
-
Interrupt IN or OUT status of SOF2
-
Interrupt IN or OUT status of SOF1
Rev. 04 — 4 February 2008
ISP1760
Embedded Hi-Speed USB host controller
© NXP B.V. 2008. All rights reserved.
80 of 110