ISP1760BE,557 NXP Semiconductors, ISP1760BE,557 Datasheet - Page 66

no-image

ISP1760BE,557

Manufacturer Part Number
ISP1760BE,557
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1760BE,557

Package Type
LQFP
Pin Count
128
Lead Free Status / RoHS Status
Compliant
NXP Semiconductors
Table 68.
ISP1760_4
Product data sheet
Bit
63
62
61
60 to 47 reserved
46 to 32 NrBytes
DW2
31 to 24 reserved
23 to 8
7 to 0
DW1
63 to 47 reserved
46
45 to 44 EPType[1:0]
43 to 42 Token[1:0]
41 to 35 Device
34 to 32 EndPt[3:1]
DW0
31
30 to 29 Mult[1:0]
28 to 18 MaxPacket
Symbol
A
H
B
Transferred
[14:0]
DataStart
Address[15:0]
S
Address[6:0]
EndPt[0]
Length[10:0]
High-speed isochronous IN and OUT: bit description
Frame[7:0]
Access
SW — sets
HW — writes
HW — writes
-
HW — writes
-
SW — writes
SW — writes
-
SW — writes
SW — writes
SW — writes
SW — writes
SW — writes
SW — writes
SW — writes
SW — writes
Value Description
-
-
-
0
-
0
-
-
-
-
-
-
-
-
-
-
-
Rev. 04 — 4 February 2008
Active: This bit is the same as the Valid bit.
Halt: Only one bit for the entire millisecond. When this bit is set, the
Valid bit is reset. The device decides to stall an endpoint.
Babble: Not applicable here.
Set to 0 for isochronous.
Number of Bytes Transferred: This field indicates the number of
bytes sent or received for this transaction. If Mult[1:0] is greater than
one, it is possible to store intermediate results in this field.
NrBytesTransferred[14:0] is 32 kB
Set to 0 for isochronous.
Data Start Address: This is the start address for data that will be sent
or received on or from the USB bus. This is the internal memory
address and not the direct CPU address.
RAM address = (CPU address
Bits 2 to 0 — Don’t care
Bits 7 to 3 — Frame number that this PTD will be sent for ISO OUT or
IN
-
This bit indicates whether a split transaction has to be executed.
0 — High-speed transaction
1 — Split transaction
Endpoint type:
01 — Isochronous
Token: This field indicates the token PID for this transaction:
00 — OUT
01 — IN
Device Address: This is the USB address of the function containing
the endpoint that is referred to by this buffer.
Endpoint: This is the USB address of the endpoint within the function.
Endpoint: This is the USB address of the endpoint within the function.
This field is a multiplier counter used by the host controller as the
number of successive packets the host controller may submit to the
endpoint in the current execution.
For details, refer to Appendix D of
Interface Specification for Universal Serial Bus Rev.
Maximum Packet Length: This field indicates the maximum number
of bytes that can be sent to or received from the endpoint in a single
data packet. The maximum packet size for an isochronous transfer is
1024 bytes. The maximum packet size for the isochronous transfer is
also variable at any whole number.
…continued
Embedded Hi-Speed USB host controller
400h) / 8
Ref. 2 “Enhanced Host Controller
1 B per PTD.
© NXP B.V. 2008. All rights reserved.
ISP1760
1.0”.
65 of 110